|
|
|
|
|
1.
18313 Accesses
|
Chemotherapeutic treatment efficacy and sensitivity are increased by adjuvant alternating electric fields (TTFields)
Eilon D Kirson, Rosa S Schneiderman, Vladimír Dbalý, František Tovaryš, Josef Vymazal, Aviran Itzhaki, Daniel Mordechovich, Zoya Gurvich, Esther Shmueli, Dorit Goldsher, Yoram Wasserman, Yoram Palti BMC Medical Physics 2009, 9:1 (8 January 2009)
Abstract | Full text | PDF
| PubMed | Cited on BioMed Central
|
Editor’s summary
Alternating electric fields, a non-toxic adjuvant cancer therapy, improves the efficacy of chemotherapeutic agents in glioma and breast cancer cell lines, animal models and glioblastoma patients, suggesting effective treatment with lower drug doses is possible.
|
|
|
2.
15737 Accesses
|
A mathematical model of optimized radioiodine-131 therapy of Graves' hyperthyroidism
Suhail AR Doi, Issa Loutfi, Kamal AS Al-Shoumer BMC Nuclear Medicine 2001, 1:1 (28 August 2001)
Abstract | Full text | PDF
| PubMed
|
|
|
3.
15045 Accesses
|
Assessment of diffuse Lewy body disease by 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG PET)
Siroos Mirzaei, Peter Knoll, Horst Koehn, Thomas Bruecke BMC Nuclear Medicine 2003, 3:1 (20 February 2003)
Abstract | Full text | PDF
| PubMed
|
|
|
4.
14405 Accesses
|
Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X
Mohsen Saghari, Majid Assadi, Mohammad Eftekhari, Mohammad Yaghoubi, Armaghan Fard-Esfahani, Jan-Mohammad Malekzadeh, Babak Sichani, Davood Beiki, Abbas Takavar BMC Nuclear Medicine 2006, 6:1 (17 February 2006)
Abstract | Full text | PDF
| PubMed
|
|
|
5.
11267 Accesses
|
Comparison of Technetium-99m-MIBI imaging with MRI for detection of spine involvement in patients with multiple myeloma
Siroos Mirzaei, Martin Filipits, Andrea Keck, Walter Bergmayer, Peter Knoll, Horst Koehn, Heinz Ludwig, Martin Pecherstorfer BMC Nuclear Medicine 2003, 3:2 (11 December 2003)
Abstract | Full text | PDF
| PubMed
|
|
|
6.
10679 Accesses
|
Re-HEDP : pharmacokinetic characterization, clinical and dosimetric evaluation in osseous metastatic patients with two levels of radiopharmaceutical dose
Eduardo Savio, Javier Gaudiano, Ana M Robles, Henia Balter, Andrea Paolino, Andrea López, Juan C Hermida, Eugenia De Marco, Graciela Martinez, Eduardo Osinaga, Furn F Knapp BMC Nuclear Medicine 2001, 1:2 (21 November 2001)
Abstract | Full text | PDF
| PubMed
|
|
|
7.
9301 Accesses
|
Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy
William D Leslie, Daniel P Levin, Sandor J Demeter BMC Nuclear Medicine 2007, 7:1 (11 January 2007)
Abstract | Full text | PDF
| PubMed
|
|
|
8.
9107 Accesses
|
Comparison of 18F SPECT with PET in myocardial imaging: A realistic thorax-cardiac phantom study
Karin Knešaurek, Josef Machac BMC Nuclear Medicine 2006, 6:5 (31 October 2006)
Abstract | Full text | PDF
| PubMed | Cited on BioMed Central
|
|
|
9.
8819 Accesses
|
Non-invasive imaging of atherosclerotic plaque macrophage in a rabbit model with F-18 FDG PET: a histopathological correlation
Zhuangyu Zhang, Josef Machac, Gerard Helft, Stephen G Worthley, Cheuk Tang, Azfar G Zaman, Oswaldo J Rodriguez, Monte S Buchsbaum, Valentin Fuster, Juan J Badimon BMC Nuclear Medicine 2006, 6:3 (25 May 2006)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
PET imaging of 18F-FDG uptake, expressed as the ratio of aortic uptake to blood activity, correlates with macrophage content within atherosclerotic lesions in a rabbit model
|
|
|
10.
8738 Accesses
|
Comparison of SPECT bone scintigraphy with MRI for diagnosis of meniscal tears
Mohammad-naghi Tahmasebi, Mohsen Saghari, Masoud Moslehi, Ali Gholamrezanezhad BMC Nuclear Medicine 2005, 5:2 (14 April 2005)
Abstract | Full text | PDF
| PubMed
|
|
|
11.
8264 Accesses
|
Perfusion scanning using 99mTc-HMPAO detects early cerebrovascular changes in the diabetic rat
Fatma J Al-Saeedi BMC Medical Physics 2008, 8:1 (13 March 2008)
Abstract | Full text | PDF
| PubMed
|
|
|
12.
8207 Accesses
|
Use of segmented CT transmission map to avoid metal artifacts in PET images by a PET-CT device
Siroos Mirzaei, Michel Guerchaft, Christopher Bonnier, Peter Knoll, Michel Doat, Peter Braeutigam BMC Nuclear Medicine 2005, 5:3 (14 June 2005)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
Attenuation corrected PET images produced by computer tomography should be processed with segmentation of transmission data in order to avoid potential artefacts caused by the presence of metal implants.
|
|
|
13.
8011 Accesses
|
Bone turnover markers are correlated with total skeletal uptake of 99mTc-methylene diphosphonate (99mTc-MDP)
Janaka Lenora, Kristina Norrgren, Ola Thorsson, Per Wollmer, Karl J Obrant, Kaisa K Ivaska BMC Medical Physics 2009, 9:3 (30 March 2009)
Abstract | Full text | PDF
| PubMed
|
|
|
14.
7943 Accesses
|
Average arterial input function for quantitative dynamic contrast enhanced magnetic resonance imaging of neck nodal metastases
Amita Shukla-Dave, Nancy Lee, Hilda Stambuk, Ya Wang, Wei Huang, Howard T Thaler, Snehal G Patel, Jatin P Shah, Jason A Koutcher BMC Medical Physics 2009, 9:4 (7 April 2009)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
Individual arterial input function (AIF) data from a limited population may be used to generate average AIF values for application to the pharmacokinetic modeling of dynamic MRI imaging data in oncology trials.
|
|
|
15.
7797 Accesses
|
188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates
Eduardo Savio, María Ures, Patricia Zeledón, Victoria Trindade, Andrea Paolino, Virginia Mockford, Antonio Malanga, Marcelo Fernández, Javier Gaudiano BMC Nuclear Medicine 2004, 4:1 (30 January 2004)
Abstract | Full text | PDF
| PubMed
|
|
|
16.
7750 Accesses
|
Hydrophilic and lipophilic radiopharmaceuticals as tracers in pharmaceutical development: In vitro – In vivo studies
Mariella Terán, Eduardo Savio, Andrea Paolino, Malcolm Frier BMC Nuclear Medicine 2005, 5:5 (18 October 2005)
Abstract | Full text | PDF
| PubMed
|
|
|
17.
7690 Accesses
|
Evaluation of the clinical value of bone metabolic parameters for the screening of osseous metastases compared to bone scintigraphy
Johann Schoenberger, Silke Rozeboom, Eva Wirthgen-Beyer, Christoph Eilles BMC Nuclear Medicine 2004, 4:3 (4 December 2004)
Abstract | Full text | PDF
| PubMed
|
|
|
18.
7377 Accesses
|
Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy
Ma Ures, Eduardo Savio, Antonio Malanga, Marcelo Fernández, Andrea Paolino, Javier Gaudiano BMC Nuclear Medicine 2002, 2:1 (14 October 2002)
Abstract | Full text | PDF
| PubMed | Cited on BioMed Central
|
|
|
19.
7156 Accesses
|
NEOadjuvant therapy monitoring with PET and CT in Esophageal Cancer (NEOPEC-trial)
Mark van Heijl, Jikke MT Omloo, Mark I van Berge Henegouwen, Olivier RC Busch, Hugo W Tilanus, Patrick MM Bossuyt, Otto S Hoekstra, Jaap Stoker, Maarten CCM Hulshof, Ate van der Gaast BMC Medical Physics 2008, 8:3 (31 July 2008)
Abstract | Full text | PDF
| PubMed
|
|
|
20.
7084 Accesses
|
Prognostic implication of late gadolinium enhancement on cardiac MRI in light chain (AL) amyloidosis on long term follow up
Raymond Q Migrino, Richard Christenson, Aniko Szabo, Megan Bright, Seth Truran, Parameswaran Hari BMC Medical Physics 2009, 9:5 (5 May 2009)
Abstract | Full text | PDF
| PubMed | Cited on BioMed Central
|
|
|
21.
7011 Accesses
|
Relationship of 99mtechnetium labelled macroaggregated albumin (99mTc-MAA) uptake by colorectal liver metastases to response following Selective Internal Radiation Therapy (SIRT)
Atul Dhabuwala, Prue Lamerton, Richard S Stubbs BMC Nuclear Medicine 2005, 5:7 (23 December 2005)
Abstract | Full text | PDF
| PubMed | Cited on BioMed Central
|
|
|
22.
6763 Accesses
|
Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging
Karin Knešaurek, Josef Machac, Zhuangyu Zhang BMC Medical Physics 2009, 9:2 (29 January 2009)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
Software processing of Rb-82 positron emission tomography (PET) images shows high repeatability for the assessment of myocardial blood flow and coronary flow reserve, supporting the value of PET for noninvasive evaluation of coronary heart disease.
|
|
|
23.
6321 Accesses
|
Planar Tc99m – sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: Results of an international multicenter trial
Teresa Massardo, Omar Alonso, Augusto Llamas-Ollier, Levin Kabasakal, Uma Ravishankar, Rossana Morales, Lucía Delgado, Ajit K Padhy BMC Nuclear Medicine 2005, 5:4 (27 July 2005)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
The low detection rate for axillary lymph node involvement shown by planar Tc99m sestamibi scintimammography suggests that this technique should be avoided in the clinical assessment of breast cancer.
|
|
|
24.
6181 Accesses
|
Differential radio-sensitivities of human chromosomes 1 and 2 in one donor in interphase- and metaphase-spreads after 60Co γ-irradiation
Rupak Pathak, Adarsh Ramakumar, Uma Subramanian, Pataje GS Prasanna BMC Medical Physics 2009, 9:6 (16 June 2009)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
Chromosome 2 may be more sensitive to radiation-induced damage than chromosome 1 during both interphase and metaphase; use of radiosensitivity differences has implications for radiation-induced health risk assessment.
|
|
|
25.
6078 Accesses
|
A preliminary study of neuroSPECT evaluation of patients with post-traumatic smell impairment
Mohammad Eftekhari, Majid Assadi, Majid Kazemi, Mohsen Saghari, Armaghan Esfahani, Babak Sichani, Ali Gholamrezanezhad, Davood Beiki BMC Nuclear Medicine 2005, 5:6 (28 November 2005)
Abstract | Full text | PDF
| PubMed
|
Editor’s summary
Brain perfusion SPECT detects areas of brain activation after odorant stimulation and is a valuable alternative imaging technique for the assessment of post-traumatic smell impairment.
|