Table 5

Kinetic constants. Kinetic constants for AMPAR

Symbol

Original Value [37]

Temperature adjusted value (Q10= 3.0)


k+1

4.59 * 106 M-1s-1

23.85 * 106 M-1s-1

k-1

4.26 * 103 s-1

22.14 * 103 s-1

k+2

28.4 * 106 M-1s-1

147.57 * 106 M-1s-1

k-2

3.26 * 103 s-1

16.94 * 103 s-1

k+3

1.27 * 106 M-1s-1

6.6 * 106 M-1s-1

k-3

45.7 s-1

237.46 s-1

α

4.24 * 103 s-1

22.03 * 103 s-1

β

900 s-1

4676.54 s-1

α1

2.89 * 103 s-1

15.02 * 103 s-1

β1

39.2 s-1

203.69 s-1

α2

172 s-1

893.74 s-1

β2

0.727 s-1

3.78 s-1

α3

17.7 s-1

91.97 s-1

β3

4.0 s-1

20.78 s-1

α4

16.8 s-1

87.3 s-1

β4

190.4 s-1

989.35 s-1


Tolle and Le Novère BMC Systems Biology 2010 4:25   doi:10.1186/1752-0509-4-25

Open Data