Resolution: standard / high Figure 1.
Double-blind placebo and matched needle. Design of the double-blind acupuncture needles. Each needle assembly comprises an
opaque guide tube (1) and upper stuffing (2) to provide resistance to the needle body
during its passage through the guide tube. The body of the penetrating needle (3)
is longer than the guide tube by an amount equal to the insertion depth, but the body
of the non-penetrating needle (4) is only long enough to allow its blunt tip to press
against the skin when the needle body is advanced to its limit. The non-penetrating
needle contains stuffing at the bottom as well (5) to give a sensation similar to
that of skin puncture and tissue penetration. Both needles have a stopper (6) that
prevents the needle handle (7) from advancing further when the sharp tip of the penetrating
needle (8) or the blunt tip of the non-penetrating needle (9) reaches the specified
position. The pedestal (10) on each needle is adhesive, allowing it to adhere firmly
to the skin surface. The diameter of the needles used in this study was 0.16 mm.
Takakura and Yajima BMC Complementary and Alternative Medicine 2007 7:31 doi:10.1186/1472-6882-7-31 |