Email updates

Keep up to date with the latest news and content from BMC Musculoskeletal Disorders and BioMed Central.

Open Access Highly Accessed Research article

Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis

Jillian M Motyl1*, Jeffrey B Driban1, Erica McAdams1, Lori Lyn Price2 and Timothy E McAlindon1

Author Affiliations

1 Division of Rheumatology, Tufts Medical Center, 800 Washington Street, Box #406, Boston, MA 02111, USA

2 The Institute for Clinical Research and Health Policy Studies, Tufts Medical Center, and Tufts Clinical and Translational Science Institute, Tufts University, 800 Washington Street, Box #63, Boston, MA 02111, USA

For all author emails, please log on.

BMC Musculoskeletal Disorders 2013, 14:166  doi:10.1186/1471-2474-14-166

Published: 10 May 2013

Abstract

Background

The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients’ physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration.

Methods

This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test.

Results

Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was −1.59 seconds (walking slower) and 0.15 seconds (walking faster).

Conclusions

Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time between −1.59 seconds (walking slower) and 0.15 seconds (walking faster) should be considered within the range of normal variability of 20-meter walking speed. The primary limitation of our study was a small sample size, which may influence the generalizability of our findings.

Keywords:
Knee; Osteoarthritis; Functional assessment