Table 5

Multiple linear regression of compliance in patients while taking Materna®

Independent Variable

Coefficient

Standard Error

p value


Age

0.00

0.002

0.73

Education

-0.02

0.014

0.09

Province

0.03

0.031

0.37

Race

0.02

0.010

0.11

Marital Status

-0.08

0.034

0.02

Weight

0.00

0.000

0.14

NVP Severity*

-0.05

0.014

0.002

Substance**

-0.06

0.044

0.20


* More severe NVP was associated with significantly lower compliance. No such effect was found with Pregvit®, which is a substantially smaller tablet, containing much lower iron content.

** alcohol, tobacco or illicit drugs