Open Access Highly Accessed Research article

Visual inspection with acetic acid as a cervical cancer test: accuracy validated using latent class analysis

Lynne Gaffikin12*, John A McGrath13, Marc Arbyn4 and Paul D Blumenthal15

Author affiliations

1 Cervical Cancer Prevention Program, JHPIEGO, Baltimore, USA

2 Evaluation and Research Technologies for Health Incorporated, Stanford USA

3 Department of Psychiatry, Johns Hopkins Medical Institution, Baltimore, USA

4 Unit of Cancer Epidemiology, Scientific Institute of Public Health, Brussels Belgium

5 Department of Obstetrics and Gynecology, Stanford University, Stanford, USA

For all author emails, please log on.

Citation and License

BMC Medical Research Methodology 2007, 7:36  doi:10.1186/1471-2288-7-36

Published: 31 July 2007

Abstract

Background

The purpose of this study was to validate the accuracy of an alternative cervical cancer test – visual inspection with acetic acid (VIA) – by addressing possible imperfections in the gold standard through latent class analysis (LCA). The data were originally collected at peri-urban health clinics in Zimbabwe.

Methods

Conventional accuracy (sensitivity/specificity) estimates for VIA and two other screening tests using colposcopy/biopsy as the reference standard were compared to LCA estimates based on results from all four tests. For conventional analysis, negative colposcopy was accepted as a negative outcome when biopsy was not available as the reference standard. With LCA, local dependencies between tests were handled through adding direct effect parameters or additional latent classes to the model.

Results

Two models yielded good fit to the data, a 2-class model with two adjustments and a 3-class model with one adjustment. The definition of latent disease associated with the latter was more stringent, backed by three of the four tests. Under that model, sensitivity for VIA (abnormal+) was 0.74 compared to 0.78 with conventional analyses. Specificity was 0.639 versus 0.568, respectively. By contrast, the LCA-derived sensitivity for colposcopy/biopsy was 0.63.

Conclusion

VIA sensitivity and specificity with the 3-class LCA model were within the range of published data and relatively consistent with conventional analyses, thus validating the original assessment of test accuracy. LCA probably yielded more likely estimates of the true accuracy than did conventional analysis with in-country colposcopy/biopsy as the reference standard. Colpscopy with biopsy can be problematic as a study reference standard and LCA offers the possibility of obtaining estimates adjusted for referent imperfections.