Email updates

Keep up to date with the latest news and content from BMC Medical Research Methodology and BioMed Central.

Open Access Research article

Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study

Jérémy Vanhelst12*, Laurent Béghin12, Alain Duhamel3, Patrick Bergman5, Michael Sjöström4 and Frédéric Gottrand1

Author Affiliations

1 Inserm U995, IFR114, Faculty of medicine, University Lille 2, Lille, France

2 CIC-9301-CHRU-INSERM, University hospital, Lille, France

3 Department of Biostatistic, CHU Lille, Univ Lille Nord de France, F-59000 Lille, France

4 Unit for Preventive Nutrition, Department of Biosciences and Nutrition, Karolinska Institute, Huddinge, Sweden

5 School of ZEducation, psychology and sport sciences, Linneaus University, Kalmar, Sweden

For all author emails, please log on.

BMC Medical Research Methodology 2012, 12:26  doi:10.1186/1471-2288-12-26

Published: 12 March 2012

Abstract

Background

Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels and patterns. The aim of this study was to compare physical activity (PA) levels and patterns obtained simultaneously by triaxial accelerometry and uniaxial accelerometry in adolescents in free-living conditions.

Methods

Sixty-two participants, aged 13-16 years, were recruited in this ancillary study, which is a part of the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA). All participants wore a uniaxial accelerometer (ActiGraph GT1M®, Pensacola, FL) and a triaxial accelerometer (RT3®, Stayhealthy, Monrovia, CA) simultaneously for 7 days. The patterns were calculated by converting accelerometer data output as a percentage of time spent at sedentary, light, moderate, and vigorous PA per day. Analysis of output data from the two accelerometers were assessed by two different tests: Equivalence Test and Bland & Altman method.

Results

The concordance correlation coefficient between the data from the triaxial accelerometer and uniaxial accelerometer at each intensity level was superior to 0.95. The ANOVA test showed a significant difference for the first three lower intensities while no significant difference was found for vigorous intensity. The difference between data obtained with the triaxial accelerometer and the uniaxial monitor never exceeded 2.1% and decreased as PA level increased. The Bland & Altman method showed good agreement between data obtained between the both accelerometers (p < 0.05).

Conclusions

Uniaxial and triaxial accelerometers do not differ in their measurement of PA in population studies, and either could be used in such studies.

Keywords:
Accelerometers; Human locomotion; Energy expenditure; Youth