Log on / register
Feedback | Support | My details
Open AccessHighly AccessResearch article

Anion gap, anion gap corrected for albumin, base deficit and unmeasured anions in critically ill patients: implications on the assessment of metabolic acidosis and the diagnosis of hyperlactatemia

Lakhmir S Chawla1,2 email, Shirley Shih1 email, Danielle Davison1 email, Christopher Junker1 email and Michael G Seneff1 email

Department of Critical Care Medicine and Anesthesiology, George Washington University Medical Center, Washington DC, USA

Division of Renal Diseases and Hypertension, Department of Medicine, George Washington University Medical Center, Washington DC, USA

author email corresponding author email

BMC Emergency Medicine 2008, 8:18doi:10.1186/1471-227X-8-18

Published: 16 December 2008

Abstract

Background

Base deficit (BD), anion gap (AG), and albumin corrected anion gap (ACAG) are used by clinicians to assess the presence or absence of hyperlactatemia (HL). We set out to determine if these tools can diagnose the presence of HL using cotemporaneous samples.

Methods

We conducted a chart review of ICU patients who had cotemporaneous arterial blood gas, serum chemistry, serum albumin (Alb) and lactate(Lac) levels measured from the same sample. We assessed the capacity of AG, BD, and ACAG to diagnose HL and severe hyperlactatemia (SHL). HL was defined as Lac > 2.5 mmol/L. SHL was defined as a Lac of > 4.0 mmol/L.

Results

From 143 patients we identified 497 series of lab values that met our study criteria. Mean age was 62.2 ± 15.7 years. Mean Lac was 2.11 ± 2.6 mmol/L, mean AG was 9.0 ± 5.1, mean ACAG was 14.1 ± 3.8, mean BD was 1.50 ± 5.4. The area under the curve for the ROC for BD, AG, and ACAG to diagnose HL were 0.79, 0.70, and 0.72, respectively.

Conclusion

AG and BD failed to reliably detect the presence of clinically significant hyperlactatemia. Under idealized conditions, ACAG has the capacity to rule out the presence of hyperlactatemia. Lac levels should be obtained routinely in all patients admitted to the ICU in whom the possibility of shock/hypoperfusion is being considered. If an AG assessment is required in the ICU, it must be corrected for albumin for there to be sufficient diagnostic utility.