Table 1

MGMR vs. SEQEM error at 100 iterations on SEQEM-A and SEQEM-B data sets

SEQEM-A sampling

SEQEM-B sampling


SEQEM

MGMR

SEQEM

MGMR


Error

SD

Error

SD

Error

SD

Error

SD


E

1.27

1 * 10-2

1.03

0.14

1.50

0.70

0.82

6 * 10-3

χ2

0.66

2 * 10-3

0.22

4 * 10-3

0.69

0.05

0.27

1 * 10-4

KL

0.29

7 * 10-4

0.14

1 * 10-4

0.18

2 * 10-4

0.17

1 * 10-4


These data sets were derived from SEQEM and MGMR(SEQEM) estimates, respectively, on 20 YRI samples. (E: relative error rate; χ2: Chi-squared error; KL: Kullback-Liebler divergence; SD: standard deviation)

Rozov et al. BMC Bioinformatics 2012 13(Suppl 6):S2   doi:10.1186/1471-2105-13-S6-S2

Open Data