<?xml version='1.0'?>
<!DOCTYPE art SYSTEM 'http://www.biomedcentral.com/xml/article.dtd'>
<art>
   <ui>1748-7161-2-2</ui>
   <ji>1748-7161</ji>
   <fm>
      <dochead>Research</dochead>
      <bibl>
         <title>
            <p>Correction effects of the ScoliOlogiC<sup>&#174; </sup>&#8222;Ch&#234;neau light" brace in patients with scoliosis</p>
         </title>
         <aug>
            <au id="A1" ca="yes">
               <snm>Weiss</snm>
               <fnm>Hans-Rudolf</fnm>
               <insr iid="I1"/>
               <email>hr.weiss@asklepios.com</email>
            </au>
            <au id="A2">
               <snm>Werkmann</snm>
               <fnm>Mario</fnm>
               <insr iid="I2"/>
               <email>m.werkmann@online.de</email>
            </au>
            <au id="A3">
               <snm>Stephan</snm>
               <fnm>Carola</fnm>
               <insr iid="I1"/>
               <email>arztsekretariat@asklepios.com</email>
            </au>
         </aug>
         <insg>
            <ins id="I1">
               <p>Asklepios Katharina Schroth Spinal Deformities Rehabilitation Centre, Korczakstr. 2, D-55566 Bad Sobernheim, Germany</p>
            </ins>
            <ins id="I2">
               <p>Orthomed Scolicare, Orthopedic Technical Services, D-55566 Bad Sobernheim, Germany</p>
            </ins>
         </insg>
         <source>Scoliosis</source>
         <issn>1748-7161</issn>
         <pubdate>2007</pubdate>
         <volume>2</volume>
         <issue>1</issue>
         <fpage>2</fpage>
         <url>http://www.scoliosisjournal.com/content/2/1/2</url>
         <xrefbib>
            <pubidlist>
               <pubid idtype="pmpid">17257399</pubid>
               <pubid idtype="doi">10.1186/1748-7161-2-2</pubid>
            </pubidlist>
         </xrefbib>
      </bibl>
      <history>
         <rec>
            <date>
               <day>31</day>
               <month>10</month>
               <year>2006</year>
            </date>
         </rec>
         <acc>
            <date>
               <day>26</day>
               <month>1</month>
               <year>2007</year>
            </date>
         </acc>
         <pub>
            <date>
               <day>26</day>
               <month>1</month>
               <year>2007</year>
            </date>
         </pub>
      </history>
      <cpyrt>
         <year>2007</year>
         <collab>Weiss et al; licensee BioMed Central Ltd.</collab>
         <note>This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</note>
      </cpyrt>
      <abs>
         <sec>
            <st>
               <p>Abstract</p>
            </st>
            <sec>
               <st>
                  <p>Background</p>
               </st>
               <p>Different bracing concepts are used today for the treatment of scoliosis. The plaster cast method worldwide seems to be the most practiced technique at the moment. CAD (Computer Aided Design) systems are on the market which allow brace adjustments without plaster. The latest development however, is the use of the ScoliOlogiC&#8482; off the shelf system enabling the orthopaedic technician to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright. This &#8222;Ch&#234;neau light" brace, developed according to the Ch&#234;neau principle, promises a reduced impediment of quality of life in the brace. However, material reduction should not result in reduced effectiveness. Therefore the primary correction effect in the &#8222;Ch&#234;neau light" brace has been evaluated and compared with that of other braces used today.</p>
            </sec>
            <sec>
               <st>
                  <p>Methods</p>
               </st>
               <p>The correction effects of the first 81 patients (main diagnosis Adolescent Idiopathic Scoliosis (AIS) [n = 64] or Early Onset Scoliosis (EOS) [n = 15]), treated according to the principle of the &#8222;Ch&#234;neau light" brace were evaluated after an average treatment time of 6 weeks by a full-body X-ray made in the standing position whilst wearing the brace and compared with the last X-ray before bracing. The average curvature angle of the whole group was 35,6&#176;, the average age was 12,9 years (SD 1,9), average Risser sign was 1,3 (SD 1,5), average Tanner rating 2,75 (SD 0,7).</p>
            </sec>
            <sec>
               <st>
                  <p>Results</p>
               </st>
               <p>The Cobb angle in the whole group was reduced by an average of 16,4&#176;, which corresponds to a correction effect of 51%. The differences were highly significant in the T-test (T = 17,4; p &lt; 0,001). The best correction effects reported in literature so far are about 40% in two different studies. The correction effect was highest in lumbar and thoracolumbar curve pattern (62 %; n = 18). In thoracic scoliosis the correction effect was 36 % (n = 41) and in double major curve pattern 50 % (n = 22). The correction effect correlated slightly negative with age (r = -0,24; p = 0,014), negatively with the Risser stage (-0,29; p = 0,0096) and correlated negatively with the Cobb angle measured before treatment (r = -0,43; p &lt; 0,0001).</p>
            </sec>
            <sec>
               <st>
                  <p>Conclusion</p>
               </st>
               <p>The use of the &#8222;Ch&#234;neau light" brace leads to correction effects above average when compared to the correction effects of other braces described in literature. The reduction of material seems to affect the desired correction in a positive way.</p>
            </sec>
         </sec>
      </abs>
   </fm>
   <bdy>
      <sec>
         <st>
            <p>Background</p>
         </st>
         <p>The latest developments in the field of bracing, aim at improving specificity <abbrgrp><abbr bid="B1">1</abbr></abbrgrp> and at a proper sagittal realignment <abbrgrp><abbr bid="B2">2</abbr></abbrgrp>.</p>
         <p>Although the effect of brace treatment has been questioned <abbrgrp><abbr bid="B3">3</abbr></abbrgrp> there is evidence that brace treatment can stop curvature progression <abbrgrp><abbr bid="B4">4</abbr><abbr bid="B5">5</abbr><abbr bid="B6">6</abbr><abbr bid="B7">7</abbr><abbr bid="B8">8</abbr><abbr bid="B9">9</abbr></abbrgrp>, reduce the frequency of surgery <abbrgrp><abbr bid="B10">10</abbr><abbr bid="B11">11</abbr><abbr bid="B12">12</abbr></abbrgrp> and improve cosmetic appearance <abbrgrp><abbr bid="B13">13</abbr><abbr bid="B14">14</abbr><abbr bid="B15">15</abbr></abbrgrp>. Poor cosmetic appearance for the patient may be the most important problem, which can be solved or at least reduced by the use of advanced bracing techniques including the best possible correction principles available to date <abbrgrp><abbr bid="B13">13</abbr></abbrgrp>. Pattern specific bracing is desirable and it was Rigo <abbrgrp><abbr bid="B1">1</abbr></abbrgrp> who implemented a new classification with 15 different curve patterns. All those curve patterns demand individual principles of correction in 3D, however 5 key patterns have been identified which we can start working with in everyday practice. These key patterns have been included into a guideline for brace construction that can be used for the custom plaster cast technique, for CAD designed braces as well as for the braces constructed via off the shelf construction kits like the "Ch&#234;neau light"<sup>&#174; </sup>brace (Patent pending) <abbrgrp><abbr bid="B16">16</abbr></abbrgrp> developed recently.</p>
         <p>Aim of this new development was to make the brace lighter, finer, easier to wear, and by this to allow a better quality of life for the patients with scoliosis under brace treatment.</p>
         <p>This is accomplished by using less material in comparison to traditional bracing systems, which are intended for scoliosis treatment (Fig. <figr fid="F1">1</figr> and <figr fid="F2">2</figr>). However material reduction should not result in reduced effectiveness. Since scoliosis corrective bracing treatment depends on the primary correction effect achieved in the brace <abbrgrp><abbr bid="B17">17</abbr><abbr bid="B18">18</abbr><abbr bid="B19">19</abbr></abbrgrp>, the primary correction effect in the &#8222;Ch&#234;neau light"<sup>&#174; </sup>brace has been evaluated and compared with that of other braces used traditionally.</p>
         <fig id="F1">
            <title>
               <p>Figure 1</p>
            </title>
            <caption>
               <p>Comparison Ch&#234;neau/Ch&#234;neau light</p>
            </caption>
            <text>
               <p><b>Comparison Ch&#234;neau/Ch&#234;neau light</b>. Dorsal and ventral aspect of two patients with comparable curve patterns. The left patient wears a Rigo-System Ch&#234;neau (RSC) brace and the patient on the right a Ch&#234;neau light brace. The material necessary for the Ch&#234;neau light brace is clearly less.</p>
            </text>
            <graphic file="1748-7161-2-2-1"/>
         </fig>
         <fig id="F2">
            <title>
               <p>Figure 2</p>
            </title>
            <caption>
               <p>Example of a double major scoliosis treated with a Ch&#234;neau light brace</p>
            </caption>
            <text>
               <p><b>Example of a double major scoliosis treated with a Ch&#234;neau light brace</b>. Nearly 13 year old girl with a 29/29&#176; Double major AIS in the ScoliOlogiC &#8222;Ch&#234;neau light" corrected to 11/9&#176; Cobb.</p>
            </text>
            <graphic file="1748-7161-2-2-2"/>
         </fig>
      </sec>
      <sec>
         <st>
            <p>Methods</p>
         </st>
         <p>From October 2005 on all patients with a "Ch&#234;neau light" brace have been listed in a data base in order to allow prospective follow-up studies in the future. The responsibility to list every patient treated with such a brace was taken over by the third author (CS). At the time this paper was prepared there were 132 Patients with an in-brace x-ray in the "Ch&#234;neau light" data base, however only 81 fulfilled the criterion to be braced for the first time. 51 Patients had a brace other than a "Ch&#234;neau light" before the onset of the treatment with this brace. The braces these patients had prior to the last one, qualitatively showed a wide variety and many of the patients became a "Ch&#234;neau light" because they had a progression in the previous brace. This is why these patients have not been included in this study.</p>
         <p>The correction effects of the first 81 patients (main diagnosis AIS [n  = 64]or EOS [n = 15]), treated according to the principles of the "Ch&#234;neau  light" brace were evaluated after an average treatment time of 6 weeks by a  full-body X-ray taken in the standing position whilst wearing the brace and  compared with the last X-ray before bracing. The average curvature angle of  the whole group was 35,6&#176; (SD 11,5; range 20-69&#176;), the average age was 12,9  years (SD 1,9; range 8-19 years), average Risser sign was 1,3 (SD 1,5; range  0-4), average Tanner rating 2,75 (SD 0,7; range 1-4). Additionally to the  patients with Idiopathic Scoliosis two patients with neuromuscular scoliosis  have been included in this study. One had a neuromuscular impairment of  unknown origin, the other due to cerebral bleeding but both were able to  walk freely.  </p>
         <p>The ScoliOlogiC<sup>&#174; </sup>off the shelf bracing system enables the orthopaedic technician to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright. This brace is called &#8222;Ch&#234;neau light" brace. The advantage of this new bracing system is that the brace is available immediately, easy adjustable and that it can also be easily modified. This avoids construction periods of sometimes more than 6 weeks, where the curve may drastically increase during periods of fast growth. The disadvantage of this bracing system is that there is a wide variability of possibilities to arrange the different shells during adjustment. Therefore the technician has to acquire a deep understanding of basic biomechanics, functional diagnosis and curve pattern identification before being able to apply "Ch&#234;neau light " braces. Another disadvantage is that due to the mobility of the shells against each other the brace needs more service than the rigid braces used to date. The service intervals should therefore not be longer than 12 weeks.</p>
         <p>Shells are available for the treatment of right thoracic and left lumbar curves in three sizes allowing brace adjustments for most of the adolescent patients. For patients with thoracolumbar curve patterns, for left thoracic, right lumbar curve patterns and for smaller sizes a "Ch&#234;neau light" brace can be constructed using the plaster cast technique.</p>
      </sec>
      <sec>
         <st>
            <p>Results</p>
         </st>
         <p>The Cobb angle in the whole sample has been reduced by an average of  16,4&#176; (SD 8,4; range 0-45&#176;), which corresponds to a correction effect of 51%  (SD 36,4; range 0-220&#176;). The average percentage of correction was calculated  on the basis of the individual percentages and not on the basis of the  average degree values. The differences were highly significant in the T-test  (T = 17,4; p &lt; 0,001). The correction effect was highest in lumbar and  thoracolumbar curve pattern (62 %; n = 18). In thoracic scoliosis the  correction effect was 36 % (n = 41) and in double major curve pattern 50 %  (n = 22). For every patient only the biggest of the curves was evaluated  which means for double major curve pattern only one curve is included into  the database and only the correction of this curve was calculated. The major  curve usually is the curve which corrects least.  </p>
         <p>The correction effect correlated slightly negative with age (r = -0,24; p = 0,014), negatively with the Risser stage (-0,29; p = 0,0096) and correlated negatively with the Cobb angle measured before treatment (r = -0,43; p = 0,0001).</p>
         <p>The correction effects differed from 0% to 220% (from 20&#176; to minus 24&#176; in one case). The patient without any correction had a brace which showed to be maladjusted in the x-ray. The readjustment was performed, however no new x-ray was made. Another patient in this sample only had a correction of 2&#176; which surely is not satisfying. However this brace was adjusted in the right way as has been shown on the x-ray, but the curve seemed too stiff to achieve more at the moment the x-ray was taken.</p>
         <p>7 patients were overcorrected (Fig. <figr fid="F3">3</figr>), two of them with a slight phase shift of the curve which means the correction forces did not aim at the apex of the curve. In those cases the brace was also readjusted resulting consequently in a possibly smaller correction after readjustment; however this is also not registered in this data base because no new in-brace x-rays were taken after correction or readjustment of the brace.</p>
         <fig id="F3">
            <title>
               <p>Figure 3</p>
            </title>
            <caption>
               <p>Example of a patient with an overcorrection in a Ch&#234;neau light brace</p>
            </caption>
            <text>
               <p><b>Example of a patient with an overcorrection in a Ch&#234;neau light brace</b>. Overcorrection of a thoracic curve from 38&#176; to -14&#176; in a T2 &#8222;Ch&#234;neau light" model in an 11-year old premenstrual girl with Tanner II. For the measurement of the corrected curve the neutral vertebra of this X-ray was used. If we would have taken the neutral vertebrae of the previous X-ray the correction effect would have been less important.</p>
            </text>
            <graphic file="1748-7161-2-2-3"/>
         </fig>
      </sec>
      <sec>
         <st>
            <p>Discussion</p>
         </st>
         <p>Different bracing concepts are used today for the treatment of scoliosis. The plaster cast method worldwide seems to be the most practiced technique at the moment. CAD systems are on the market which allow brace adjustments without plaster. The latest development however, is the use of the ScoliOlogiC<sup>&#174; </sup>off the shelf system enabling the orthopaedic technician to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright designed for full day treatment (Fig. <figr fid="F1">1</figr>, <figr fid="F2">2</figr>, <figr fid="F3">3</figr>, <figr fid="F4">4</figr>).</p>
         <fig id="F4">
            <title>
               <p>Figure 4</p>
            </title>
            <caption>
               <p>Example of a patient with two different high correction braces</p>
            </caption>
            <text>
               <p><b>Example of a patient with two different high correction braces</b>. 13-year old girl with AIS (39&#176; thoracic). In the previous brace she had 22&#176; high thoracic, 12&#176; low thoracic and 5&#176; lumbar, while in the Ch&#234;neau light<sup>&#174; </sup>brace she has 22&#176; high thoracic, 8&#176; low thoracic and 11&#176; lumbar. The lumbar correction has not been improved after this x-ray in order to achieve a better balance of curves after treatment and a better cosmetic result. The reduction of material in the Ch&#234;neau light<sup>&#174; </sup>brace compared to the previous brace is clearly visible.</p>
            </text>
            <graphic file="1748-7161-2-2-4"/>
         </fig>
         <p>After having improved the correction of the braces also in sagittal plane, we were able to improve the correction effect in the frontal plane as well. Compared to the correction effects we achieved 2003 <abbrgrp><abbr bid="B8">8</abbr></abbrgrp>, the results now seem significantly better.</p>
         <p>In the normal range of brace indications a correction effect of at least 20% is necessary to prevent progression <abbrgrp><abbr bid="B17">17</abbr></abbrgrp>, while a correction effect of at average 30% promises some final corrections <abbrgrp><abbr bid="B18">18</abbr></abbrgrp>. A correction effect of 40% and more in a growing adolescent may lead to a final correction of at average 7&#176; Cobb <abbrgrp><abbr bid="B6">6</abbr></abbrgrp>.</p>
         <p>Wong et al. <abbrgrp><abbr bid="B19">19</abbr></abbrgrp> report correction effects of an average of 40 % in patients with an average Cobb degree of 30,6&#176; (21&#176; &#8211; 43&#176;). However in this collective no patients with double curve pattern have been included, which generally corrected worse than single curves in our preliminary study <abbrgrp><abbr bid="B20">20</abbr></abbrgrp>.</p>
         <p>Bullmann et al. <abbrgrp><abbr bid="B21">21</abbr></abbrgrp> reported average correction effects of 43% in the custom Ch&#234;neau brace constructed via plaster cast in patients with a Cobb angle of 31&#176; (25&#176; &#8211; 40&#176;). The final rate of success in this study however, was only 58%, which has to be regarded as rather disappointing, when compared to the success rate of 80% we reported on in another study <abbrgrp><abbr bid="B9">9</abbr></abbrgrp> with an average correction effect of less than 40% in custom Ch&#234;neau braces constructed via plaster cast.</p>
         <p>A modular off the shelf orthopaedic brace for recumbent treatment has been described by Trudell <abbrgrp><abbr bid="B22">22</abbr></abbrgrp>. This so called "bending brace", does not correct in 3D and the shells provided do not allow a proper adjustment for a full-day treatment. A full-day treatment, however, is necessary for a successful end result <abbrgrp><abbr bid="B23">23</abbr></abbrgrp>.</p>
         <p>Additionally, this brace needs metal connection plates to adjust the shells to the anterior and posterior upright, whilst in the "Ch&#234;neau light" brace the shells are connected directly to the uprights giving the system the flexibility needed for the treatment of different curve pattern.</p>
         <p>Therefore the "Ch&#234;neau light" brace can be regarded an effective tool (possible to be worn full time, good correction effects) for the treatment of adolescents with scoliosis in the majority of the cases. Only certain thoracolumbar curve pattern as well as left thoracic and right lumbar curves need a pattern specific CAD or plaster based construction as long as specific shells are not available to also address those curves.</p>
         <p>The data of all patients treated with the "Ch&#234;neau light" brace currently are submitted to a database allowing a prospective follow-up of the patients until the end of treatment. An evaluation on quality of life during brace treatment is underway.</p>
         <p>Unfortunately, even today, studies with insufficient bracing technologies are published with correction effects of at average less than 25% <abbrgrp><abbr bid="B24">24</abbr></abbrgrp>, while the standard in advanced centres is reported to be different for more than 20 years now. In the latter study <abbrgrp><abbr bid="B24">24</abbr></abbrgrp> less than 80% of the population had at least some correction effect in the brace. To irresponsibly apply such poor treatment nowadays can be easily avoided and it needs to be, for our patients deserve a positive effect when they sacrifice their quality of life over years to the prescribed brace in good faith.</p>
      </sec>
      <sec>
         <st>
            <p>Conclusion</p>
         </st>
         <p>The use of the "Ch&#234;neau light" brace leads to correction effects above average when compared to correction effects of other braces described in literature. The reduction of material seems to affect the desired correction in a positive way.</p>
      </sec>
      <sec>
         <st>
            <p>Competing interests</p>
         </st>
         <p>The first author is currently applying for a patent relating to the content of this paper. None of the authors has received any reimbursements, fees, funding, or salary related to the content of this paper.</p>
      </sec>
      <sec>
         <st>
            <p>Authors' contributions</p>
         </st>
         <p>HRW: Study design, data acquisition, analysis and interpretation of data, preparation of the manuscript, corresponding author</p>
         <p>MW: Data acquisition.</p>
         <p>CS: Data acquisition, data base</p>
      </sec>
   </bdy>
   <bm>
      <ack>
         <sec>
            <st>
               <p>Acknowledgements</p>
            </st>
            <p>The authors are thankful to Orthomed, Orthopedic devices, Bad Sobernheim, Germany, for their kind support.</p>
         </sec>
      </ack>
      <refgrp>
         <bibl id="B1">
            <title>
               <p>Intra-observer reliability of a new classification correlating with brace treatment</p>
            </title>
            <aug>
               <au>
                  <snm>Rigo</snm>
                  <fnm>M</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2004</pubdate>
            <volume>7</volume>
            <fpage>63</fpage>
            <xrefbib>
               <pubid idtype="doi">10.1080/13638490310001654736</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B2">
            <title>
               <p>Sagittal Counter Forces (SCF) in the Treatment of Idiopathic Scoliosis &#8211; A Preliminary Report</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
               <au>
                  <snm>Dallmayer</snm>
                  <fnm>R</fnm>
               </au>
               <au>
                  <snm>Gallo</snm>
                  <fnm>D</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2006</pubdate>
            <volume>9</volume>
            <fpage>24</fpage>
            <lpage>30</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1080/13638490500038126</pubid>
                  <pubid idtype="pmpid" link="fulltext">16352502</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B3">
            <title>
               <p>Adolescent idiopathic scoliosis: the effect of brace treatment on the incidence of surgery</p>
            </title>
            <aug>
               <au>
                  <snm>Goldberg</snm>
                  <fnm>CJ</fnm>
               </au>
               <au>
                  <snm>Moore</snm>
                  <fnm>DP</fnm>
               </au>
               <au>
                  <snm>Fogarty</snm>
                  <fnm>EE</fnm>
               </au>
               <au>
                  <snm>Dowling</snm>
                  <fnm>FE</fnm>
               </au>
            </aug>
            <source>Spine</source>
            <pubdate>2001</pubdate>
            <volume>26</volume>
            <fpage>42</fpage>
            <lpage>47</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1097/00007632-200101010-00009</pubid>
                  <pubid idtype="pmpid" link="fulltext">11148644</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B4">
            <title>
               <p>The Boston bracing system for idiopathic scoliosis: Follow-up results in 295 patients</p>
            </title>
            <aug>
               <au>
                  <snm>Emans</snm>
                  <fnm>JB</fnm>
               </au>
               <au>
                  <snm>Kaelin</snm>
                  <fnm>A</fnm>
               </au>
               <au>
                  <snm>Bancel</snm>
                  <fnm>P</fnm>
               </au>
               <au>
                  <snm>Hall</snm>
                  <fnm>JE</fnm>
               </au>
               <au>
                  <snm>Miller</snm>
                  <fnm>ME</fnm>
               </au>
            </aug>
            <source>Spine</source>
            <pubdate>1986</pubdate>
            <volume>11</volume>
            <fpage>792</fpage>
            <lpage>801</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1097/00007632-198610000-00009</pubid>
                  <pubid idtype="pmpid">3810295</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B5">
            <title>
               <p>Standard der Orthesenversorgung in der Skoliosebehandlung</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
            </aug>
            <source>Med Orth Tech</source>
            <pubdate>1995</pubdate>
            <volume>5</volume>
            <fpage>323</fpage>
            <lpage>330</lpage>
         </bibl>
         <bibl id="B6">
            <title>
               <p>Estimating the final outcome of brace treatment for idiopathic thoracic scoliosis at 6-month follow-up</p>
            </title>
            <aug>
               <au>
                  <snm>Landauer</snm>
                  <fnm>F</fnm>
               </au>
               <au>
                  <snm>Wimmer</snm>
                  <fnm>C</fnm>
               </au>
               <au>
                  <snm>Behensky</snm>
                  <fnm>H</fnm>
               </au>
            </aug>
            <source>Pediatr Rehabil</source>
            <pubdate>2003</pubdate>
            <volume>6</volume>
            <issue>3&#8211;4</issue>
            <fpage>201</fpage>
            <lpage>7</lpage>
            <xrefbib>
               <pubid idtype="pmpid" link="fulltext">14713586</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B7">
            <title>
               <p>[Long-term results of the conservative treatment of scoliosis using the Cheneau brace]</p>
            </title>
            <aug>
               <au>
                  <snm>Hopf</snm>
                  <fnm>C</fnm>
               </au>
               <au>
                  <snm>Heine</snm>
                  <fnm>J</fnm>
               </au>
            </aug>
            <source>Z Orthop Ihre Grenzgeb</source>
            <pubdate>1985</pubdate>
            <volume>123</volume>
            <issue>3</issue>
            <fpage>312</fpage>
            <lpage>22</lpage>
            <xrefbib>
               <pubid idtype="pmpid">4050044</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B8">
            <title>
               <p>Qualit&#228;tskontrolle korrigierender Rumpforthesen in der Skoliosebehandlung</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
               <au>
                  <snm>El Obeidi</snm>
                  <fnm>N</fnm>
               </au>
               <au>
                  <snm>Botens-Helmus</snm>
                  <fnm>C</fnm>
               </au>
            </aug>
            <source>Med Orth Tech</source>
            <pubdate>2003</pubdate>
            <volume>126</volume>
            <fpage>39</fpage>
            <lpage>46</lpage>
         </bibl>
         <bibl id="B9">
            <title>
               <p>Brace treatment during pubertal growth spurt in Girls with Idiopathic scoliosis (IS) &#8211; A prospective trial comparing two different concepts</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
               <au>
                  <snm>Weiss</snm>
                  <fnm>G</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2005</pubdate>
            <volume>8</volume>
            <fpage>199</fpage>
            <lpage>206</lpage>
            <xrefbib>
               <pubid idtype="pmpid" link="fulltext">16087554</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B10">
            <title>
               <p>Incidence of surgery in conservatively treated patients with scoliosis</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
               <au>
                  <snm>Weiss</snm>
                  <fnm>G</fnm>
               </au>
               <au>
                  <snm>Schaar</snm>
                  <fnm>HJ</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2003</pubdate>
            <volume>6</volume>
            <fpage>111</fpage>
            <lpage>8</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1080/13638490310001593446</pubid>
                  <pubid idtype="pmpid" link="fulltext">14534048</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B11">
            <title>
               <p>Effect of conservative management on the prevalence of surgery in patients with adolescent idiopathic scoliosis</p>
            </title>
            <aug>
               <au>
                  <snm>Rigo</snm>
                  <fnm>M</fnm>
               </au>
               <au>
                  <snm>Reiter</snm>
                  <fnm>C</fnm>
               </au>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2003</pubdate>
            <volume>6</volume>
            <fpage>209</fpage>
            <lpage>214</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1080/13638490310001642054</pubid>
                  <pubid idtype="pmpid" link="fulltext">14713587</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B12">
            <title>
               <p>Effectiveness of conservative treatment for idiopathic scoliosis &#8211; a combination of brace treatment and physical treatment</p>
            </title>
            <aug>
               <au>
                  <snm>Maruyama</snm>
                  <fnm>T</fnm>
               </au>
               <au>
                  <snm>Kitagawa</snm>
                  <fnm>T</fnm>
               </au>
               <au>
                  <snm>Takeshita</snm>
                  <fnm/>
               </au>
               <au>
                  <snm>Mochizuki</snm>
                  <fnm>K</fnm>
               </au>
               <au>
                  <snm>Nakamura</snm>
                  <fnm>K</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2004</pubdate>
            <volume>7</volume>
            <fpage>56</fpage>
         </bibl>
         <bibl id="B13">
            <title>
               <p>Korsettversorgungsstrategien in der Skoliosebehandlung</p>
            </title>
            <aug>
               <au>
                  <snm>Rigo</snm>
                  <fnm>M</fnm>
               </au>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
            </aug>
            <source>Wirbels&#228;ulendeformit&#228;ten &#8211; Konservatives Management</source>
            <publisher>Pflaum, Munich</publisher>
            <editor>Weiss HR</editor>
            <pubdate>2003</pubdate>
         </bibl>
         <bibl id="B14">
            <title>
               <p>3 D Correction of Trunk Deformity in Patients with Idiopathic Scoliosis Using Ch&#234;neau Brace</p>
            </title>
            <aug>
               <au>
                  <snm>Rigo</snm>
                  <fnm>M</fnm>
               </au>
            </aug>
            <source>Research into Spinal Deformities 2</source>
            <publisher>Amsterdam, IOS Press</publisher>
            <editor>Stokes IAF</editor>
            <pubdate>1999</pubdate>
            <fpage>362</fpage>
            <lpage>365</lpage>
         </bibl>
         <bibl id="B15">
            <title>
               <p>Radiological and cosmetic improvement 2 years after brace weaning &#8211; a case report</p>
            </title>
            <aug>
               <au>
                  <snm>Rigo</snm>
                  <fnm>M</fnm>
               </au>
            </aug>
            <source>Pediatric Rehabilitation</source>
            <pubdate>2003</pubdate>
            <volume>6</volume>
            <fpage>195</fpage>
            <lpage>199</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1080/13638490310001636826</pubid>
                  <pubid idtype="pmpid" link="fulltext">14713585</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B16">
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
            </aug>
            <source>"Best Practice" in conservative scoliosis care</source>
            <publisher>Pflaum, Munich</publisher>
            <edition>2</edition>
            <pubdate>2007</pubdate>
         </bibl>
         <bibl id="B17">
            <title>
               <p>Adolescent idiopathic scoliosis, bracing, and the Hueter-Volkmann principle</p>
            </title>
            <aug>
               <au>
                  <snm>Castro</snm>
                  <fnm>FP</fnm>
                  <suf>Jr</suf>
               </au>
            </aug>
            <source>Spine J</source>
            <pubdate>2003</pubdate>
            <volume>3</volume>
            <fpage>180</fpage>
            <lpage>5</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1016/S1529-9430(02)00557-0</pubid>
                  <pubid idtype="pmpid" link="fulltext">14589197</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B18">
            <title>
               <p>End Vertebra Angle &#8211; A Roentgenographic Method to Describe a Scoliosis. A Follow-up Study of Idiopathic Scoliosis Treated with the Boston Brace</p>
            </title>
            <aug>
               <au>
                  <snm>Appelgren</snm>
                  <fnm>G</fnm>
               </au>
               <au>
                  <snm>Willner</snm>
                  <fnm>S</fnm>
               </au>
            </aug>
            <source>Spine</source>
            <pubdate>1990</pubdate>
            <volume>15</volume>
            <fpage>71</fpage>
            <lpage>74</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1097/00007632-199002000-00004</pubid>
                  <pubid idtype="pmpid">2326714</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B19">
            <title>
               <p>A comparison of treatment effectiveness between the CAD/CAM method and the manual method for managing adolescent idiopathic scoliosis</p>
            </title>
            <aug>
               <au>
                  <snm>Wong</snm>
                  <fnm>MS</fnm>
               </au>
               <au>
                  <snm>Cheng</snm>
                  <fnm>JC</fnm>
               </au>
               <au>
                  <snm>Lo</snm>
                  <fnm>KH</fnm>
               </au>
            </aug>
            <source>Prosthet Orthot Int</source>
            <pubdate>2005</pubdate>
            <volume>29</volume>
            <fpage>105</fpage>
            <lpage>11</lpage>
            <xrefbib>
               <pubid idtype="pmpid">16180383</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B20">
            <title>
               <p>Ein neuer Ansatz zur Konstruktion korrigierender Skolioseorthesen &#8211; Das Baukastenprinzip</p>
            </title>
            <aug>
               <au>
                  <snm>Weiss</snm>
                  <fnm>HR</fnm>
               </au>
            </aug>
            <source>Med Orth Tech</source>
            <pubdate>2005</pubdate>
            <volume>128</volume>
            <fpage>71</fpage>
            <lpage>82</lpage>
         </bibl>
         <bibl id="B21">
            <title>
               <p>[Prospective evaluation of braces as treatment in idiopathic scoliosis]</p>
            </title>
            <aug>
               <au>
                  <snm>Bullmann</snm>
                  <fnm>V</fnm>
               </au>
               <au>
                  <snm>Halm</snm>
                  <fnm>HF</fnm>
               </au>
               <au>
                  <snm>Lerner</snm>
                  <fnm>T</fnm>
               </au>
               <au>
                  <snm>Lepsien</snm>
                  <fnm>U</fnm>
               </au>
               <au>
                  <snm>Hackenberg</snm>
                  <fnm>L</fnm>
               </au>
               <au>
                  <snm>Liljenqvist</snm>
                  <fnm>U</fnm>
               </au>
            </aug>
            <source>Z Orthop</source>
            <pubdate>2004</pubdate>
            <volume>142</volume>
            <fpage>403</fpage>
            <lpage>9</lpage>
            <xrefbib>
               <pubidlist>
                  <pubid idtype="doi">10.1055/s-2004-822843</pubid>
                  <pubid idtype="pmpid" link="fulltext">15346300</pubid>
               </pubidlist>
            </xrefbib>
         </bibl>
         <bibl id="B22">
            <title>
               <p>Modular Orthopedic Brace</p>
            </title>
            <aug>
               <au>
                  <snm>Trudell</snm>
                  <fnm>TG</fnm>
               </au>
            </aug>
            <source>US Patent US005449338A</source>
            <pubdate>1995</pubdate>
         </bibl>
         <bibl id="B23">
            <title>
               <p>A meta-analysis of the efficacy of non-operative treatments for idiopathic scoliosis</p>
            </title>
            <aug>
               <au>
                  <snm>Rowe</snm>
                  <fnm>DE</fnm>
               </au>
               <au>
                  <snm>Bernstein</snm>
                  <fnm>SM</fnm>
               </au>
               <au>
                  <snm>Riddick</snm>
                  <fnm>MF</fnm>
               </au>
               <au>
                  <snm>Adler</snm>
                  <fnm>F</fnm>
               </au>
               <au>
                  <snm>Emans</snm>
                  <fnm>JB</fnm>
               </au>
               <au>
                  <snm>Gardner-Bonneau</snm>
                  <fnm>F</fnm>
               </au>
            </aug>
            <source>J Bone Joint Surg Am</source>
            <pubdate>1997</pubdate>
            <volume>79</volume>
            <issue>5</issue>
            <fpage>664</fpage>
            <lpage>74</lpage>
            <xrefbib>
               <pubid idtype="pmpid" link="fulltext">9160938</pubid>
            </xrefbib>
         </bibl>
         <bibl id="B24">
            <title>
               <p>[Brace treatment of idiopathic scoliosis]</p>
            </title>
            <aug>
               <au>
                  <snm>Tonseth</snm>
                  <fnm>KA</fnm>
               </au>
               <au>
                  <snm>Wever</snm>
                  <fnm>DJ</fnm>
               </au>
            </aug>
            <source>Tidsskr Nor Laegeforen</source>
            <pubdate>2005</pubdate>
            <volume>125</volume>
            <fpage>170</fpage>
            <lpage>2</lpage>
            <xrefbib>
               <pubid idtype="pmpid" link="fulltext">15665890</pubid>
            </xrefbib>
         </bibl>
      </refgrp>
   </bm>
</art>
