Table 1

Audiometry findings, present regimen and length of aminoglycoside use in group I(n = 7) and II (n = 4) patients showing audiological evidence of hearing loss

Sr. No. (Group)
Length of treatment (Days)
Present regimen (Drugs)
PTA0
PTA2
PTA4
PTA6
PTA8
PTA10
PTAc

1 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
2 (I)
60
A, F, E, P, Py
N
HFL
HFL
HFL
FLAT
FLAT
FLAT
3 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
4 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
FLAT
FLAT
5 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
6 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
7 (I)
180
A, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
8 (II)
120
K, F, E, P, Py
N
N
N
HFL
FLAT
FLAT
FLAT
9 (II)
180
K, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL
10 (II)
180
K, F, E, P, Py
N
N
N
HFL
HFL
FLAT
FLAT
11 (II)
180
K, F, E, P, Py
N
N
N
HFL
HFL
HFL
HFL

A = amikacin, F = flouroquinolone, E = ethionamide, P = Para-amino salicylic acid, Py = Pyrazinamide, K = kanamycin, Days = days of aminoglycoside use in present regimen, PTA0 = baseline pure tone audiogram, PTA2 = pure tone audiogram after 2 months of aminoglycoside use, PTA4 = pure tone audiogram after 4 months of aminoglycoside use, PTA6 = pure tone audiogram after 6 months of aminoglycoside use, PTA8 = pure tone audiogram after 8 months of aminoglycoside use, PTA10 = pure tone audiogram after 10 months of aminoglycoside use, PTAc = pure tone audiogram after completion of therapy for MDR-TB, N = Normal, HFL = High frequency loss (hearing loss involving frequencies of 4000, 6000 and 8000 Hz), FLAT = Hearing loss involving frequencies in range of 250–3000 Hz along with involvement of 4000, 6000 and 8000 Hz (Criteria for hearing loss as defined in methods section).

Duggal and Sarkar BMC Ear, Nose and Throat Disorders 2007 7:5   doi:10.1186/1472-6815-7-5