Skip to main content

Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study

Abstract

Background

Percutaneous vertebroplasty (PVP) typically involves conventional lower-viscosity cement injection via bipedicular approach. Limited evidence is available comparing the clinical outcomes and complications in treating osteoporotic vertebral compression fractures (OVCFs) with PVP using high-viscosity cement through unipedicular or bipedicular approach.

Methods and design

Fifty patients with OVCFs were randomly allocated into two groups adopting unipedicular or bipedicular PVP. The efficacy of unipedicular and bipedicular PVP was assessed by comparing operation time, X-ray exposure time, incidence of complications, vertebral height restoration, and improvement of the visual analogue scale (VAS), Oswestry disability index (ODI) and Short Form-36 (SF-36) General Health Survey scores.

Results

The mean operative and exposure time to X-rays in the unipedicular PVP group was less than that of the bipedicular group (pā€‰<ā€‰0.05). No statistically significant differences were observed in the VAS score, ODI score, SF-36 score, cement leakage rate or vertebral height restoration between the two groups (pā€‰>ā€‰0.05).

Conclusion

Unipedicular and bipedicular PVP are safe and effective treatments for OVCF. Compared with bipedicular PVP, unipedicular PVP entails a shorter surgical time and lower X-ray irradiation.

Peer Review reports

Background

Osteoporosis is the most common systemic disorder worldwide, characterized by low bone mass, altered bone microarchitecture and increased risk of fragility fracture [1, 2]. In the European Union, an estimated 22 million women and 5.5 million men are afflicted with osteoporosis, with an annual cost of fractures related to osteoporosis pegged at euro 37.0 billion, expected to increase by 25Ā % in 2025 [3]. The most common fragility fractures associated with osteoporosis are vertebral compression fractures (OVCFs), affecting 25Ā % of postmenopausal women and more than 200 million individuals worldwide [4]. OVCFs cause substantial pain and deformity, leading to disability and poor quality of life. The usual treatment of OVCF includes analgesics, external braces and physical therapy. However, a few patients may still complain of severe pain after conservative treatments and even show progressive collapse of the vertebral body and kyphosis with or without neurological deficit [5ā€“7]. Various techniques of vertebral body augmentation have been developed in an effort to treat these refractory cases. Over the past few decades, percutaneous vertebroplasty (PVP) has gained popularity as the optimal treatment modality for OVCF. PVP provided rapid pain relief and long-lasting effects in a large case series and nonrandomized controlled trails [6, 8, 9]. Although relatively safe and effective, PVP is associated with complications including cement leakage, soft tissue damage, pedicle fracture, nerve injury and spinal epidural hematoma [10, 11].

The detection rate of cement leakage ranges from 7Ā % by x-ray to 82Ā % using computed tomography (CT) [12]. While most leakages are asymptomatic, serious complications of nerve root or spinal cord compression and pulmonary embolism cannot be ruled out [10, 11, 13]. Reducing cement leakage using vertebral venography, gel-foam embolization, and kyphoplasty resulted in inconclusive outcomes [8, 14, 15]. High-viscosity cements have been demonstrated to effectively reduce the risk of epidural and venous cement leakage, thereby improving overall clinical safety [16ā€“19]. The standard technique is typically carried out using a bipedicular approach [18, 19]. In recent years, unipedicular PVP has been advocated, reducing the operating and radiation exposure time, lowering the risk of cement leakage and complications caused by vertebral pedicle puncture. In addition, it increased the cost-effectiveness of the procedure as well as clinical efficacy. To compare the efficacy and adverse effects of unipedicular PVP with that of bipedicular PVP using high-viscosity cement, we conducted a prospective randomized and controlled study in our hospital. To the best of our knowledge, there has been no such report published until now.

Methods

Patients and controls

The Institutional Review Board of our hospital (Clinical Hospital of Yangzhou University Institutional Review Board Committee) approved this study, and patients provided informed consent prior to the study. From November 2010 to October 2012, a total of 58 patients with OVCF adopting PVP with high-viscosity bone cement were included in our study. Clinical indications for vertebral augmentation were regularly confirmed by an interdisciplinary team of oncologists, radiation oncologists, spine surgeons, and interventional radiologists prior to the intervention.

Study inclusion criteria were as follows: (1) age over 50Ā years; (2) single-level OVCF; (3) focal back pain in the midline unresponsive to at least 8Ā weeks of conservative treatments; (4) back pain related to the location of the OVCF on magnetic resonance imaging (MRI) radiographs; (5) presence of an apparent bone edema in the fractured vertebra on T2-weighted short-tau inversion recovery sequences (STIR) in MRI; (6) bilateral pedicle intact without fracture; and (7) decreased bone mineral density (T scoresā€‰<ā€‰āˆ’1). We excluded patients with (1) vertebral compression fracture due to causes other than osteoporosis; (2) spinal cord compression or stenosis of the vertebral canalā€‰>ā€‰30Ā % of the local canal diameter; (3) neurologic deficits; (4) incurable bleeding disorders; (5) systemic or local spine infections; (6) severe comorbidity of heart, liver, kidney, and lung intolerance to surgery.

All eligible patients were assigned a serial number according to the consecutive sequence of hospitalization and allocated to group U (using unipedicular approach) or group B (using bipedicular approach) randomly by computer. The study population consisted of 24 patients in group U (8 male and 16 female, mean ageā€‰=ā€‰69.2Ā years, rangeā€‰=ā€‰52ā€“81 years) and 26 patients in the group B (10 male and 16 female, mean ageā€‰=ā€‰70.5Ā years, rangeā€‰=ā€‰57ā€“83 years). All procedures were performed by the same surgeon.

Surgical technique

All surgical procedures were conducted under general anesthesia, with the patient in prone position on a carbon-fiber radiolucent, C-arm table. After localizing the fractured vertebra using fluoroscopy, the surgeon placed overlapping palm on the vertebral spinous process to push ventrally slowly and partially reduce the fractured vertebra. A small skin puncture was made approximately 2.5Ā cm off of mid-line. The introducer was directed to the junction of the middle and anterior 1/3 of the affected vertebral body under C-arm fluoroscopic guidance. Once the needle was in the optimal position, the high-viscosity polymethylmethacrylate (PMMA) bone cement was injected with a specially designed delivery system (Disc-O-Tech Medical Technologies Ltd. Herzliya, Israel) according to the manufacturerā€™s specifications. The injection procedure was carefully controlled under strict lateral fluoroscopy and stopped whenever epidural or paravertebral opacification was observed or the cement reached the dorsal quarter of the vertebral body.

Outcome measurements

We emphasized both surgical complications and clinical outcomes in both groups three days and two years after surgery. Outcome measures included: (1) surgery time (from skin incision to suturing), exposure time to the X-ray C-arm machine and cement dosage; (2) Visual Analog Scale (VAS) score for analgesic efficacy evaluation; (3) Oswestry Disability Index (ODI) for functional assessment; (4) Short Form-36 General Health Survey (SF-36) for quality of life evaluation: Physical Component Summary (PCS) and the Mental Component Summary (MCS); (5) complications including cement leakage and adjacent vertebral fractures; and (6) radiographic outcomes including anterior and middle vertebral body height variation, (calculated by fractured vertebral body height/normal vertebral body heightā€‰Ć—ā€‰100Ā %). Normal heights of the vertebrae were defined as the mean of the equivalent values for the adjacent superior and inferior non-fractured vertebrae. Anterior and middle vertebral height was defined as the distance between the upper and lower endplates at the anterior and middle vertebral body wall and in the center of the vertebral body.

Statistical analysis

Data were presented as the meanā€‰Ā±ā€‰standard deviation. The SPSS for Windows Version 13.0 (SPSS, Chicago, IL) was used for the analysis. Statistical analysis was performed by an independent statistician blinded to the surgical procedures. The statistical significance of pre- and post-surgical clinical and radiographic data within each group and between groups was evaluated using independent t-test and chi-square test. The difference of cement leakage between two groups was assessed using the Ļ‡2 test. The level of statistical significance was set at p <0.05.

Results

Surgical parameters

The mean surgery time was 41.2ā€‰Ā±ā€‰5.2Ā min in group U, which was shorter than 55.7ā€‰Ā±ā€‰7.3Ā min in group B (pā€‰<ā€‰0.001) (TableĀ 1). Patients were exposed to X-rays 33.7ā€‰Ā±ā€‰5.2Ā min in group U and 46.5ā€‰Ā±ā€‰6.6Ā min in group B, and the difference was statistically significant (pā€‰<ā€‰0.001) (TableĀ 1). The bone cement volume was 3.1ā€‰Ā±ā€‰0.4Ā mL in group U and 5.0ā€‰Ā±ā€‰0.5Ā mL in group B, and this difference was also statistically significant (pā€‰<ā€‰0.001) (TableĀ 1).

Table 1 Surgical parameters of the studied population

Clinical outcomes

There was no difference between the 2 groups in terms of the pre-operative VAS, ODI, PCS and MCS measurements (Table 2). Patients in both groups exhibited marked and sustained pain reduction, function and quality of life improvement. Significant statistical differences were found before and after operation in terms of VAS, ODI and SF-36 scores (Table 2). However, no statistical differences were found 3 days or 2 years postoperatively between the 2 groups in terms of the clinical outcomes (Table 2).

Table 2 Clinical outcomes of the two groups

Radiological outcomes

There were no surgical complications in either group. The bone cement leakage rate was 20.8Ā % (5 of 24) in the group U and 34.6Ā % (9 in 26) in group B, which was not a statistically significant difference (pā€‰=ā€‰0.28). Of the 5 bone cement leakages in group U, one occurred into the anterior vertebra, 2 were leakages into the disc and another 2 were venous leaks. Of the 9 bone cement leakages in group B, 3 occurred into the disc, one into paravertebral, 2 into epidural, and another 3 were venous leaks. However, no clinical symptoms were identified due to leakage and no special treatment was necessary.

The anterior and middle vertebral heights of the fractured vertebra before surgery showed no significant diffeence between the 2 groups (Table 3). Similarly, no statistical difference was found 3Ā days later or even after 2Ā years. However, significant statistical differences were found before and after the operation in terms of the anterior and middle vertebral heights of the fractured vertebra (Table 3).

Table 3 Radiological outcomes of the two groups

Discussion

PVP is the optimal treatment for OVCF and provides rapid pain relief and stabilization of the fractured vertebral bodies [8, 20, 21]. Although cement leakage is reported as high as 73Ā % for both PVP types, most leakages remain clinically asymptomatic, and even small quantities of leakage may have a significant clinical impact [12]. The three factors that may influence the cement flow into and out of the vertebral body include: bone and fracture-related parameters, cement properties, and injection methods. Although fracture morphology is impossible to control, the cement properties and method of injection may be manipulated to ultimately decrease the complication rate.

Viscosity of bone cement used in PVP is hypothesized to influence the outcome of the procedure in various ways. Increased viscosity leads to increased circularity of the cement cloud and decreased spreading distance [22, 23]. PVP with high-viscosity cement offers all the advantages, especially minimizing the risk of cement leakage and significantly increasing the clinical safety [22, 24]. In the PVP procedure, unipedicular approach is being increasingly used to treat OVCF, to reduce medical costs and X-ray exposure, as well as for better clinical efficacy [25, 26]. In our prospective, randomized study, both unipedicular and bipedicular PVP group achieved satisfactory results and patientsā€™clinical outcome parameters were significantly improved and consistent compared to pre-surgical levels. The improvement in the clinical outcome and recovery of vertebral heights were not significantly different between the two groups under the strict inclusion criteria.

In theory, bipedicular PVP shows increased incidence of complications such as tissue trauma, nerve injury and pedicle fractures. However, in our study, no pedicle fractures or nerve damage occurred in either group. The complications resulting largely from poor operative technique can be minimized at the operator level.

Some clinical studies have positively correlated the bone cement injection volume with the leakage of bone cement [27]. In theory, the risk of bone cement leakage is also twice that of unipedicular approach. However the difference in cement leakage rates between unipedicular and bipedicular PVP with conventional viscosity cement was not statistically significant [28ā€“31]. The cement leakages in PVP with high-viscosity cement are still unknown. A larger volume of injected cement through the bipedicular approach is also more likely to result in extravasations. The most common cement leakage was venous leakage (6.1Ā %) and intradiscal leakage (8.2Ā %) in PVP with high-viscosity Confidence bone cement reported by Anselmetti et al. [22]. However, the leakage rate was almost as high as 47Ā % reported by Georgy et al. [18]. The cement leakage rates in the above two studies were far different. By comparison, we found that the biggest difference may be the methods adopted (unipedicular approach by Anselmetti vs. bipedicular approach by Georgy) and cement leakages detected (CT by Anselmetti vs. plain film by Georgy). CT is now regarded as the gold standard to assess cement leakage [12]. Whether the lower cement leakage rate reported by Anselmetti was due to the different PVP is unclear. In this study, the cement leakage rates of both groups were lower but not statistically significant compared with PVP using standard low-viscosity cement. The results suggested that increased bone cement injection did not result in increased bone cement leakage rate, which may be attributed to the nature of high-viscosity bone cement itself.

The X-ray exposure and operation time of unipedicular approach were significantly reduced. Unipedicular PVP lessens the radiation dose, thereby reducing health risks to the medical staff performing the PVP. If 5Ā % of all vertebral compression fractures in the United States were treated by unipedicular kyphoplasty, instead of bipedicular kyphoplasty, the savings would beā€‰>ā€‰$32 million per year [32]. Thus, our results support the concept that the unipedicular technique is a faster, cost-effective alternative that still provides a comparable correction of spinal deformity to the bipedicular technique. The unipedicular technique is specifically indicated for the elderly, or patients who have more than one affected vertebra.

The limitations of our study are related to the relatively small sample size and the follow-up of only three days and two years. We also failed to perform a direct comparison of vertebroplasty with kyphoplasty using high-viscosity cement. Further study using a larger sample size and longer or more frequent follow-ups are needed to confirm our results.

Conclusion

Unipedicular and bipedicular PVP are safe and effective treatments for OVCF. Although the pain relief and improved physical ability were comparable with either technique, we encourage the use of the unipedicular approach as the preferred surgical technique for treatment of OVCFs due to less operation time, limited X-ray exposure, minimal cement introduction and extravasation.

Abbreviations

PVP:

Percutaneous vertebroplasty

OVCFs:

Osteoporotic vertebral compression fractures

VAS:

Visual analogue scale

ODI:

Oswestry disability index

SF-36:

Short Form-36

MRI:

Magnetic resonance imaging

PMMA:

polymethylmethacrylate

References

  1. Litwic A, Cooper C, Dennison E. Osteoporosis therapies in 2014. Panminerva Med. 2014;56:273ā€“83.

    CASĀ  PubMedĀ  Google ScholarĀ 

  2. Appelman-Dijkstra NM, Papapoulos SE. Novel approaches to the treatment of osteoporosis. Best Pract Res Clin Endocrinol Metab. 2014;28:843ā€“57.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  3. Hernlund E, Svedbom A, Ivergard M, Compston J, Cooper C, Stenmark J, et al. Osteoporosis in the European Union: medical management, epidemiology and economic burden. A report prepared in collaboration with the International Osteoporosis Foundation (IOF) and the European Federation of Pharmaceutical Industry Associations (EFPIA). Arch Osteoporos. 2013;8:136.

    ArticleĀ  CASĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  4. Johnell O, Kanis JA. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int. 2006;17:1726ā€“33.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  5. Chen D, An ZQ, Song S, Tang JF, Qin H. Percutaneous vertebroplasty compared with conservative treatment in patients with chronic painful osteoporotic spinal fractures. J Clin Neurosci. 2014;21:473ā€“7.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  6. Liu J, Li X, Tang D, Cui X, Yao M, Yu P, et al. Comparing pain reduction following vertebroplasty and conservative treatment for osteoporotic vertebral compression fractures: a meta-analysis of randomized controlled trials. Pain Physician. 2013;16:455ā€“64.

    PubMedĀ  Google ScholarĀ 

  7. Kim KW, Cho KJ, Kim SW, Lee SH, An MH, Im JH. A nation-wide, outpatient-based survey on the pain, disability, and satisfaction of patients with osteoporotic vertebral compression fractures. Asian Spine J. 2013;7:301ā€“7.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  8. Stevenson M, Gomersall T, Lloyd Jones M, Rawdin A, Hernandez M, Dias S, et al. Percutaneous vertebroplasty and percutaneous balloon kyphoplasty for the treatment of osteoporotic vertebral fractures: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2014;18:1ā€“290.

    ArticleĀ  Google ScholarĀ 

  9. Kim JH, Yoo SH. Long-term follow-up of percutaneous vertebroplasty in osteoporotic compression fracture: minimum of 5 years follow-up. Asian Spine J. 2012;6:6ā€“14.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  10. Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD. Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J. 2011;11:839ā€“48.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  11. Lee MJ, Dumonski M, Cahill P, Stanley T, Park D, Singh K. Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications. Spine (Phila Pa 1976). 2009;34:1228ā€“32.

    ArticleĀ  Google ScholarĀ 

  12. Martin DJ, Rad AE, Kallmes DF. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection. Acta Radiol. 2012;53:569ā€“72.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  13. Venmans A, Lohle P, Van Rooij W, Verhaar H, Mali WTM. Frequency and outcome of pulmonary polymethylmethacrylate embolism during percutaneous vertebroplasty. Am J Neuroradiol. 2008;29:1983ā€“5.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  14. He SC, Teng GJ, Fang W, Deng G, Guo JH, Zhu GY. [Value of intraosseous venography in percutaneous vertebroplasty for treatment of symptomatic vertebral hemangiomas]. Zhonghua Yi Xue Za Zhi. 2010;90:3188ā€“92.

    PubMedĀ  Google ScholarĀ 

  15. Bhatia C, Barzilay Y, Krishna M, Friesem T, Pollock R. Cement leakage in percutaneous vertebroplasty: effect of preinjection gelfoam embolization. Spine (Phila Pa 1976). 2006;31:915ā€“9.

    ArticleĀ  Google ScholarĀ 

  16. Lador R, Liberman S, Ben-Galim P, Dreiangel N, Reitman CA, Hipp JA. A cadaver study to compare vertebral augmentation with a high-viscosity cement to augmentation with conventional lower-viscosity cement. J Spinal Disord Tech. 2013;26:68ā€“73.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  17. Rapan S, Jovanovic S, Gulan G, Boschi V, Kolarevic V, Dapic T. Vertebroplasty--high viscosity cement versus low viscosity cement. Coll Antropol. 2010;34:1063ā€“7.

    CASĀ  PubMedĀ  Google ScholarĀ 

  18. Georgy BA. Clinical experience with high-viscosity cements for percutaneous vertebral body augmentation: occurrence, degree, and location of cement leakage compared with kyphoplasty. AJNR Am J Neuroradiol. 2010;31:504ā€“8.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  19. Nieuwenhuijse MJ, Muijs SP, van Erkel AR, Dijkstra SP. A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty: viscosity associated with cement leakage. Spine (Phila Pa 1976). 2010;35:E1037ā€“44.

    ArticleĀ  Google ScholarĀ 

  20. Huang H, He S, Fang W, Zhu H, Guo J, Deng G, et al. [Percutaneous vertebroplasty for treatment of painful osteoporotic vertebral compression fractures: a retrospective analysis of clinical efficacy]. Zhonghua Yi Xue Za Zhi. 2014;94:2119ā€“22.

    PubMedĀ  Google ScholarĀ 

  21. Voormolen MH, Mali WP, Lohle PN, Fransen H, Lampmann LE, van der Graaf Y, et al. Percutaneous vertebroplasty compared with optimal pain medication treatment: short-term clinical outcome of patients with subacute or chronic painful osteoporotic vertebral compression fractures. The VERTOS study. AJNR Am J Neuroradiol. 2007;28:555ā€“60.

    CASĀ  PubMedĀ  Google ScholarĀ 

  22. Anselmetti GC, Zoarski G, Manca A, Masala S, Eminefendic H, Russo F, et al. Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures. Cardiovasc Intervent Radiol. 2008;31:937ā€“47.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  23. Baroud G, Crookshank M, Bohner M. High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine. 2006;31:2562ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  24. Ruger M, Schmoelz W. Vertebroplasty with high-viscosity polymethylmethacrylate cement facilitates vertebral body restoration in vitro. Spine (Phila Pa 1976). 2009;34:2619ā€“25.

    ArticleĀ  Google ScholarĀ 

  25. Chen C, Bian J, Zhang W, Zhao C, Wei H. Unilateral Versus Bilateral Vertebroplasty for Severe Osteoporotic Vertebral Compression Fractures. J Spinal Disord Tech. 2014;27(8):E301ā€“4.

  26. Gao W, Mi S, Gao J. [Percutaneous vertebroplasty to treat osteoporotic vertebral compression fractures combined with intravertebral clefts by unilateral approach]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2012;26:1330ā€“5.

    PubMedĀ  Google ScholarĀ 

  27. Kaufmann TJ, Trout AT, Kallmes DF. The effects of cement volume on clinical outcomes of percutaneous vertebroplasty. AJNR Am J Neuroradiol. 2006;27:1933ā€“7.

    CASĀ  PubMedĀ  Google ScholarĀ 

  28. Wang Z, Wang G, Yang H. Comparison of unilateral versus bilateral balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. J Clin Neurosci. 2012;19:723ā€“6.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  29. Li LH, Sun TS, Liu Z, Zhang JZ, Zhang Y, Cai YH, et al. Comparison of unipedicular and bipedicular percutaneous kyphoplasty for treating osteoporotic vertebral compression fractures: a meta-analysis. Chin Med J (Engl). 2013;126:3956ā€“61.

    Google ScholarĀ 

  30. Rebolledo BJ, Gladnick BP, Unnanuntana A, Nguyen JT, Kepler CK, Lane JM. Comparison of unipedicular and bipedicular balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures: a prospective randomised study. Bone Joint J. 2013;95-B:401ā€“6.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  31. Chen C, Wei H, Zhang W, Gu Y, Tang G, Dong R, et al. Comparative study of kyphoplasty for chronic painful osteoporotic vertebral compression fractures via unipedicular versus bipedicular approach. J Spinal Disord Tech. 2011;24:E62ā€“5.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  32. Steinmann J, Tingey CT, Cruz G, Dai Q. Biomechanical comparison of unipedicular versus bipedicular kyphoplasty. Spine (Phila Pa 1976). 2005;30:201ā€“5.

    ArticleĀ  Google ScholarĀ 

Download references

Acknowledgements

The authors would like to thank Pro Yongxiang Wang and Dr Jun Cai for the technical support and for proof-reading the original manuscript. The authors wish to thank Jijun Huang and Zhiqiang Zhang for their assistance with translation. We also thank all study participants. Finally, we thank all those who provided medical writing services on behalf of Shanghai BIOON Info-tech Co.Ltd.

Funding

This work was funded by National Natural Science Foundation for Young Scholars of China (Grant No. 81401830) as well as Natural Science Foundation for Young Scholars of Jiangsu Province, China (Grant No. BK 20140496).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xinmin Feng.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authorsā€™ contributions

LZ participated in study design/data analysis and drafted the manuscript, and acted as first author. ZJL participated in the design of the study, analyzed the radiographic and functional measurements. XMF participated in the design of the study and carried out the operation. JCW assisted with funding, supervised the study design and data analysis, revised the manuscript and acted as the corresponding author. YPT assisted with clinical examinations and surgery. JDY participated in the design of the study and coordinated the research groups. SFZ participated in data collection and interpretation. All authors read and approved the final manuscript.

Rights and permissions

Open Access Ā This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the articleā€™s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the articleā€™s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhang, L., Liu, Z., Wang, J. et al. Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study. BMC Musculoskelet Disord 16, 145 (2015). https://doi.org/10.1186/s12891-015-0590-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-015-0590-6

Keywords