Skip to main content
  • Research article
  • Open access
  • Published:

Economic evaluation of continuous subcutaneous insulin infusion for children with diabetes - a pilot study: CSII application for children – economic evaluation

Abstract

Background

The objective of this study is to assess the cost of using continuous subcutaneous insulin infusion to treat children with type-1diabetes in Bulgaria, considering changes in body mass index (BMI) and the glycated hemoglobin. The study was performed from the perspective of the Bulgarian National Health Insurance Fund (NHIF) and patients.

Methods

A total of 34 pediatric type-1-diabetes patients were observed for 7 months, divided into 2 groups – on pumps and on insulin analogue therapy. Patient demographic data, BMI and glycated hemoglobin level were obtained and recorded. The cost of insulin, pumps, and consumables were calculated and compared with changes in glycated hemoglobin level. The incremental cost-effectiveness ratio was below the threshold value of gross domestic product per capita.

Results

The results were sensitive to changes in glycated hemoglobin level. Improvements associated with glycemic control led to a reduced glycated hemoglobin level that could ensure good diabetes management, but its influence on BMI in growing children remains unclear.

Conclusion

Continuous subcutaneous insulin infusion appears to be more cost-effective for the Bulgarian pediatric population and health care system.

Peer Review reports

Background

Type-1-diabetes (T1DM) patients treated with unmodified regular human insulin (RHI) rarely achieve their glycemic target and often suffer from postprandial hyperglycemic incidents, together with an increased risk of hypoglycemia in the post-absorptive period [1]. Recent meta-analyses in the literature have found improved glycemic control with continuous subcutaneous insulin infusion (CSII) compared with multiple daily injections (MDI) of insulin for patients with diabetes mellitus. For example, in Australia, CSII is predominantly used in type-1-diabetes mellitus patient populations [2]. Continuous subcutaneous insulin infusion (CSII) is considered an option for type-1diabetic patients unsatisfactorily controlled with multiple daily injections (MDI). Short-acting analogs are superior to regular human insulin in CSII. There is evidence supporting the advantages of short-acting analog-based CSII over MDI in type-1 diabetes. The reduction of glycated hemoglobin (HbA1c) level with CSII was evident in trials enrolling patients with mean age greater than 10 years [3].

The main goals for managing children with type-1-diabetes mellitus include achieving near-normal blood sugar levels, minimizing hypoglycemic incidents, optimizing quality of life, and preventing or delaying long-term complications. Continuous subcutaneous insulin infusion (CSII) is a treatment option that can assist in achieving all of these goals in all ages of children [4]. European Union countries reimburse insulin therapy for individuals with health insurance, but for CSII reimbursement, a variety of approaches exist [57]. The objective of this study is to assess the cost of using CSII of insulin to treat children with type-1diabetes in Bulgaria and to compare it with the changes in BMI and HbA1c. The study was performed from the perspective of the Bulgarian NHIF and patients. The main study question discussed is "will the use of CSII be cost-effective for the Bulgarian health care system?"

Methods

Literature search

PubMed was searched using keywords CSII, type-1diabetes, pediatric population and all articles analyzing the safety, efficacy, and cost-effectiveness of CSII usage in the pediatric population were selected. In total, 4 studies were selected and their objectives, methodologies, results and conclusions were compared [2, 810].

Type of the CSII usage study

A combined retrospective and prospective analysis of children patient records after the introduction of CSII was performed based on the patients’ records and observation. This study was performed at the Endocrinology Clinic of University pediatric hospital of the Medical University, Sofia. It was reviewed and approved by the Ethics committee of the Science medical council of the Medical University in Sofia.

Patient selection

A total of 34 children with type-1diabetes were observed divided into two groups: with an active group using CSII and a control group using analogue insulin therapy with a pen device. Thirty children in the country use CSII, and of these, 17 were surveyed, after their parents signed informed-consent forms. The children were consecutively recruited from the end of 2007 when the first pumps were administered. The active group included all children who began using the CSII pumps during the period 2007–2011 when the data collection began. Also since 2010, all children were transferred to real time insulin pumps; therefore at the moment of observation, they all used the same type of pump from the same manufacturer.

The control group was formed after reviewing patient records and random selection according to age, duration of diabetes, entrance BMI and HbA1c level. Their parents also signed informed-consent forms.

Data collection

The data was collected by observing the therapeutic effects on both groups from the Endocrinology pediatric clinic from 01.02.2012 to 31.08.2012 (7 months). During this period, we measured the diabetes maintenance phase after CSII introduction. Data for the selected children was collected on their demographics, age, gender, weight, duration of disease, therapeutic schema (CSII or analogue insulin treatment with a pen device) and HbA1c before the inclusion in the pump program, and at the end of the observation.

Cost – effectiveness analysis

For both groups of children, the health care resources used by them were recorded, namely insulin, pumps (1 for 4 years), consumables for pumps (6–10 sets and 6–10 reservoirs), strips (n = 1100 per patient per year), glucometers (1 for 5 years including sensor prices), GP and endocrinology visits, and hospitalization due to diabetes. Sensors were used from 7 to 10 days. Yearly costs of CSII, blood glucose monitoring systems, insulin therapy, and strips were calculated by multiplying the number of resources used by their prices. Prices of pumps and blood glucose monitoring systems were collected from the manufacturers’ websites. To calculate the yearly pump costs, the prices were divided by 4, which is recommended by the manufacturers as the period of use for initial users [11]. All other costs were taken from the Bulgarian NHIF tariff [12]. Costs are presented in Bulgarian leva (BGN). At the time, the exchange rate was 1 Euro: 1.95 BGN.

The primary outcome observed was the change in HbA(1c) before the pump introduction and at the end of the study. The secondary outcome observed was the BMI change during the same period. In this pilot study we did not include the hypoglycemia episodes due to lack of data for all children. Children were introduced to pumps in different time periods, and in order to calculate the corresponding decrease in the HbA1c level, the total decrease during the period was divided into the duration of the period when the particular child was using the pump. Finally the average decrease for both groups was calculated.

Cost effectiveness ratio (CER) was calculated by dividing the yearly cost of the health care resources and the changes in the HbA1c level. Incremental cost-effectiveness ratio (ICER) was also calculated by dividing the differences in costs between the active and control group with the differences in the HbA1c level.

Sensitivity analysis

To test the robustness of the results, a one-way sensitivity analysis was performed by consecutively varying the changes in the HbA1c within the standard deviation interval for both groups of patients with 0.05.

Statistical analysis

Descriptive statistics were applied to the patient’s characteristic and outcomes. A T-test analysis was also performed to test the statistical significance in the outcome changes.

Results

Analysis of published studies

There are 4 studies in the literature that discuss the efficacy, safety and/or cost-effectiveness of CSII usage in the pediatric population – Table 1. The number of observed patients varied from 19 to 95. All of these studies measured the decrease in HbA1C, and some, in addition, focused on patients’ demographic characteristics, glucose level, hypoglycemia, and quality of life. All of the studies conclude that CSII is safe and effective, leading to greater decreases in HbA1c levels, allowing for improved quality of life, decreased hypoglycemic events and improved child and parent adherence as shown in Table 1.

Table 1 Summary of the main findings from the published studies

The published studies define the HbA1c level as the widely accepted measure of diabetes control in pediatric practice. Positive therapeutic results after CSII introduction that might lead to better long-term outcomes are observed.

Results of the national study

The University pediatric clinic has been introducing CSII on the request of the parents, with only 30 children having applied so far. From 1999 to 2011, 17 children with diabetes type-1 were observed mean age 113,82 months in the active group and 112.,41 in the control group. The duration of diabetes was a little lower in the control group – Table 2.

Table 2 Patient demographic

In both groups, BMI increased and the change was higher in the active group with lower standard deviation (SD), meaning that these children maintained stable growth. A stable and significant decrease in the HbA1c level is observed in the group of patients using CSII (1.25 ± 0.99). It is also evident that the CSII groups maintained close to target levels of HbA1c (6,5%) at the end of the study, while in the control group, the target control was not observed – Table 3.

Table 3 Changes in the study outcomes

The CSII price of the blood glucose monitoring system was 7850 BGN (4025,64 Euro) thus reaching 1962,50 BGN (1006,41 Euro) per patient per year – Table 4. The transmitter cost was 425 BGN (217,95 Euro). The test strips cost 1039,35 BGN (533 Euro) year (1100 strips per year) and their average cost according to the duration of the disease was 7369,93 BGN (3779.45 Euro) from onset and diagnosis. This cost was equal in both groups per protocol and was not included in the cost analysis. Insulin usage due to the strict control was lower in the group of children with CSII and therefore their yearly cost of insulin therapy was lower (Table 3). The total cost of therapy in the group of CSII users was higher mainly due to the CSII pumps and related consumables.

Table 4 Cost of the therapy (BGN)

The cost per unit of decrease in HbA1c in the control group was 1780,91 BGN (913.13 Euro) and almost 3.5 times higher in the group using CSII – Table 5. But the ICER showing the additional cost per unit of decrease in HbA1c was lower than the recommended threshold of yearly gross domestic product (GDP) per capita. This means that CSII usage is cost-effective for the Bulgarian health care system.

Table 5 Cost –effectiveness analysis (BGN)

The results were sensitive to changes in the HbA1c level in both groups. The ICER ratio for CSII pumps remained below the threshold value when the difference in HbA1c level was below 0,42% in the control group and 1,30% in the active group. When the differences in the HbA1c level in the control group increased, the ICER also increased, while in the active group, the opposite occurred. This means that the therapy with the pumps is an efficient alternative for the health care system in Bulgaria when children manage to decrease their HbA1c level by more than 1.30% (Figure 1).

Figure 1
figure 1

ICER change in active and control group when differences in HbA1c change.

Discussion

Continuous subcutaneous insulin infusion (CSII) systems are of a limited usage because they are not reimbursed by the Health Insurance Fund in Bulgaria. No official criteria for CSII usage in child populations have been established and only parents with sufficiently high income are able to afford such a therapeutic approach. In this sense, evaluation of the cost-effectiveness of CSII usage is influenced by a number of factors, such as health insurance policy, parents’ preferences, and therapeutic standards. Our study shows that the usage of CSII with child populations is an efficient therapy and confirms similar findings reported in the literature on improvements in terms of better metabolic control, reduced rates of complications and better quality of life [2, 13].

The study also shows that the children using CSII manage to maintain stable and target HbA1c levels, which are preconditions for better diabetes management (UKPDS, DCCT). The studies of the CSII usage in child populations are very limited for comparing long-term results in detail, but bearing in mind the evidence for the adult population, it can be predicted that strict and reliable disease control for children will support their long-term survival.

One limitation of this study is the small patient sample due to the limited number of children on CSII in Bulgaria, but it includes more than 57% of all the CSII users in the country, which ensures reliable results for the whole group. The number of the patients is twice as high as Wilsons’ study [8]. Some of the costs are not included in the analysis (strips, physicians visits, hospitalizations) because they were equal for the both groups and would not change the ICER. We did not calculate the cost-effectiveness of CSII pumps related to the second observed outcome – BMI, because an increase in children’s weight as a result of their normal developmental growth was observed in the both groups.

Our study aimed to provide evidence for the Bulgarian NHIF to include CSII within the reimbursement system. Strict criteria for appropriate selection of children must be developed, as well as cost controls in order to make the final decision. The reimbursement practice in some countries provides such evidence, as in Serbia, where insurance authorities are paying for consumables and patients’ families are paying for pumps. In countries with high GDP, CSII is included within the scope of the reimbursement system [7].

Conclusion

Improvements in glycemic control associated with CSII led to reduced HbA(1c), which can ensure good diabetes management, but its control over BMI in growing children remains unclear. CSII pumps appear to be cost-effective for the Bulgarian pediatric population and health care system.

References

  1. Mosca A, Lapolla A, Gillery P: Glycemic control in the clinical management of diabetic patients. Clin Chem Lab Med. 2013, 51 (4): 753-66. doi:10.1515/cclm-2012-0594

    Article  CAS  PubMed  Google Scholar 

  2. Cohen N, Minshall ME, Sharon-Nash L, Zakrzewska K, Valentine WJ, Palmer AJ: Continuous subcutaneous insulin infusion versus multiple daily injections of insulin: economic comparison in adult and adolescent type 1 diabetes mellitus in Australia. Pharmacoeconomics. 2007, 25 (10): 881-97. 10.2165/00019053-200725100-00006.

    Article  PubMed  Google Scholar 

  3. Monami M, Lamanna C, Marchionni N, Mannucci E: Continuous subcutaneous insulin infusion versus multiple daily insulin injections in type 1 diabetes: a meta-analysis. Acta Diabetol. 2010, 47: 77-81. 10.1007/s00592-009-0132-5.

    Article  CAS  PubMed  Google Scholar 

  4. Tamborlane W, Swan K, Sikes K, Steffen A, Weinzimer S: The renaissance of insulin pump treatment in childhood type 1 diabetes. Rev Endocr Metab Disord. 2006, 7 (3): 205-213. doi:10.1007/s11154-006-9018-9

    Article  CAS  PubMed  Google Scholar 

  5. Soltesz G, Patterson CC, Dalquist G: EURODIAB Study Group Worldwide childhood type 1 diabetes incidence – what can we learn from epidemiology?. Pediatr Diabetes. 2007, 8 (Suppl 6): 6-14. doi:10.1111/j.1399-5448.2007.00280.x

    Article  PubMed  Google Scholar 

  6. Carle F, Gesuita R, Bruno G, Coppa GV, Falorni A, Lorini R, et al: Diabetes incidence in 0- to 14-year age-group in Italy. Diabetes Care. 2004, 27: 2790-6. 10.2337/diacare.27.12.2790. doi:10.2337/diacare.27.12.2790

    Article  PubMed  Google Scholar 

  7. Stipancic G, La Grasta SL, Sepec M, Radica A, Skrabic V, Severinski S, Tiljak M: Regional differences in incidence and clinical presentation of type 1 diabetes in children aged under 15 years in Croatia. Croat Med J. 2012, 53 (2): 141-148. 10.3325/cmj.2012.53.141. doi:10.3325/cmj.2012.53.141

    Article  PubMed  PubMed Central  Google Scholar 

  8. Plotnik L, et al: Safety and Effectiveness of Insulin Pump Therapy in Children and Adolescents With Type 1 Diabetes. Diabetes care. 2003, 26 (4): 1142-1146. 10.2337/diacare.26.4.1142.

    Article  Google Scholar 

  9. Bode BW, Sabbah HT, Gross TM, Fredrickson LP, Davidson PC: Diabetes management in the new millennium using insulin pump therapy. Diabetes Metab Res Rev. 2002, 18: S14-S20.

    Article  CAS  PubMed  Google Scholar 

  10. Wilson D, et al: A two-center randomized controlled feasibility trial of insulin pump therapy in young children with diabetes. Diabetes care. 2005, 28: 15-19. 10.2337/diacare.28.1.15.

    Article  PubMed  Google Scholar 

  11. Medtronic MiniMed, Inc. http://www.medtronic-diabetes.bg/,

  12. National Health Insurance Fund-Bulgaria. http://www.nhif.bg,

  13. Cohen O, Korner A, Chlup R, Zoupas CS, Ragozin AK, Wudi K, et al: Improved glycemic control through continuous glucose sensor-augmented insulin pump therapy: prospective results from a community and academic practice patient registry. J Diabetes Sci Technol. 2009, 3: 804-811.

    Article  PubMed  PubMed Central  Google Scholar 

Pre-publication history

Download references

Acknowledgements

We wish to thank to the staff of University pediatric clinic for their contribution to this project; and for their valuable technical support and for their help in collecting the data.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Valentina Petkova.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

EP carried out the data collection of the data. VP participated in the design of the study and performed the document and statistical analysis and helped to draft the manuscript. MK participated in the design and coordination. GP participated in the design of the study and in the statistical analysis and helped to draft the manuscript. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Petkova, E., Petkova, V., Konstantinova, M. et al. Economic evaluation of continuous subcutaneous insulin infusion for children with diabetes - a pilot study: CSII application for children – economic evaluation. BMC Pediatr 13, 155 (2013). https://doi.org/10.1186/1471-2431-13-155

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2431-13-155

Keywords