Table 1

Demographics data for OH patients and controls
Controls Ocular Hypertension p < 0.05
Male: Female 27:25 24:28 0.765*
Age (years) 54.8 ± 10.4 56 ± 9.6 0.431
IOP (mmHg) 16.7 ± 1.5 23.96 ± 1.3 0.001
Refractive errors (diopters) - 0.2 ± 1.5 - 0.4 ± 1.6 0.320
Visual acuity (LogMAR) 0.0 ± 0.1 0.0 ± 0.1 1.00
Corneal radius (mm) 7.76 ± 0.14 7.83 ± 0.14 0.210
Corneal thickness (μm) 552.3 ± 3.08 558.4 ± 4.15 0.274
C/D area ratio 0.33 ± 0.11 0.37 ± 0.12 0.068
Visual field MD (dB) 0.28 ± 1.1 0.31 ± 1.2 0.670
Visual field CPSD (dB) 0.65 ± 0.4 0.90 ± 0.5 0.542

Demographics data of intraocular pressure (IOP), cup/disc area ratio (C/D), visual field mean defect (MD), visual field corrected pattern standard deviation (CPSD), “*” Chi-square test for ocular hypertensive (OH) patients and controls.

Cellini et al.

Cellini et al. BMC Ophthalmology 2012 12:33   doi:10.1186/1471-2415-12-33

Open Data