Background

Screening and monitoring in pregnancy are strategies used by healthcare providers to identify high-risk pregnancies so that they can provide more targeted and appropriate treatment and follow-up care, and to monitor fetal well-being in both low- and high-risk pregnancies. The use of many of these techniques is controversial and their ability to detect fetal compromise often unknown. Theoretically, appropriate management of maternal and fetal risk factors and complications that are detected in pregnancy and labour could prevent a large proportion of the world's 3.2 million estimated annual stillbirths, as well as minimise maternal and neonatal morbidity and mortality.

Methods

The fourth in a series of papers assessing the evidence base for prevention of stillbirths, this paper reviews available published evidence for the impact of 14 screening and monitoring interventions in pregnancy on stillbirth, including identification and management of high-risk pregnancies, advanced monitoring techniques, and monitoring of labour. Using broad and specific strategies to search PubMed and the Cochrane Library, we identified 221 relevant reviews and studies testing screening and monitoring interventions during the antenatal and intrapartum periods and reporting stillbirth or perinatal mortality as an outcome.

Results

We found a dearth of rigorous evidence of direct impact of any of these screening procedures and interventions on stillbirth incidence. Observational studies testing some interventions, including fetal movement monitoring and Doppler monitoring, showed some evidence of impact on stillbirths in selected high-risk populations, but require larger rigourous trials to confirm impact. Other interventions, such as amniotic fluid assessment for oligohydramnios, appear predictive of stillbirth risk, but studies are lacking which assess the impact on perinatal mortality of subsequent intervention based on test findings. Few rigorous studies of cardiotocography have reported stillbirth outcomes, but steep declines in stillbirth rates have been observed in high-income settings such as the U.S., where cardiotocography is used in conjunction with Caesarean section for fetal distress.

Conclusion

There are numerous research gaps and large, adequately controlled trials are still needed for most of the interventions we considered. The impact of monitoring interventions on stillbirth relies on use of effective and timely intervention should problems be detected. Numerous studies indicated that positive tests were associated with increased perinatal mortality, but while some tests had good sensitivity in detecting distress, false-positive rates were high for most tests, and questions remain about optimal timing, frequency, and implications of testing. Few studies included assessments of impact of subsequent intervention needed before recommending particular monitoring strategies as a means to decrease stillbirth incidence. In high-income countries such as the US, observational evidence suggests that widespread use of cardiotocography with Caesarean section for fetal distress has led to significant declines in stillbirth rates. Efforts to increase availability of Caesarean section in low-/middle-income countries should be coupled with intrapartum monitoring technologies where resources and provider skills permit.

Introduction

Although most pregnancies progress normally, some are more complex because of antenatal or intrapartum conditions that place the mother, the developing fetus, or both at a higher risk for complications than pregnancies without these conditions. Pre-existing chronic conditions, as well as conditions that arise during pregnancy, can threaten the life and health of the fetus or the mother. Maternal hypertension, diabetes mellitus, renal disease, and autoimmune disorders, as well as placentation abnormalities and congenital anomalies, are examples of conditions that can place the pregnancy at high risk of fetal compromise. Fetal growth restriction arising from placental insufficiency is a significant cause of perinatal mortality (stillbirth or neonatal death) and morbidity (complications of prematurity) internationally [1]. Additionally, if not detected and addressed promptly, fetal hypoxia resulting from placental dysfunction or poor fetal tolerance of labour can cause stillbirth, neonatal death, or physical and developmental disabilities in the child [2].

Relatively non-invasive techniques exist to screen for a number of these conditions during the antenatal and intrapartum periods. These screening tools can also be used to monitor fetal well-being via assessment of fetal movement, heart rate, and/or growth; and feto-placental and/or uteroplacental circulatory dynamics, whether routinely at antenatal care (ANC) visits or via more complex screening tests in high-risk and post-term pregnancies [3]. Despite widespread clinical use of many of these techniques, the sensitivity and predictive value of these tests and methods are often too poor to reliably detect problems. Prompt detection of risk factors and complications is also critical, as measures of fetal distress or compromise associated with certain high-risk conditions may rapidly lead to fetal demise. Certain maternal or fetal problems may prompt the need for pharmacological intervention, early delivery, or surgical delivery (Caesarean section) rather than vaginal delivery. Optimising gestational age at delivery and judicious timing of corticosteroid administration are key challenges in responding to fetal compromise arising pre-term. The appropriate use of accurate screening and monitoring technologies can facilitate timely referral to facilities capable of providing operative delivery or other interventions for complications prior to or during labour. On the other hand, screening and monitoring techniques during pregnancy and the intrapartum period could inadvertently result in avoidable perinatal deaths, either because the technique itself is harmful or because it increases the risk of inappropriate or unnecessary use of drugs, induction of labour, early delivery, or Caesarean section.

Most studies of fetal screening and monitoring to date have been conducted in high-resource settings. Theoretically, evidence-based screening and monitoring techniques that are already in widespread use in high-income countries could be promoted to prevent stillbirth and other adverse pregnancy outcomes in low-/middle-income countries. We focus here on monitoring methods during pregnancy and the intrapartum periods, including identification and care of high-risk pregnancies and advanced monitoring techniques, with attention given where relevant to the feasibility and potential impact of implementing these techniques in low-resource settings where most stillbirths occur.

Methods

This is the fourth in a series of papers on the evidence for interventions that impact stillbirths. Details of the search strategy and review procedures for this paper are described in detail in Paper 1 of this series [4]. Each study was assigned a level of evidence (LOE) based on its design strength, size, and findings. The cumulative strength of the body of evidence for each intervention was then graded as A, B, C, or D using the SIGN grading system; impact estimates for each intervention were further cumulatively assessed as having no/negative, uncertain, some or clear evidence of benefit.

We reviewed 14 screening and monitoring interventions for evidence of impact which are included in this paper (Table 1). For most of these interventions, we first reviewed studies reporting how effectively a given screening or monitoring test detected potential risk to the fetus (primarily observational studies), followed by studies that assessed the utility and/or impact of screening or monitoring interventions in preventing adverse outcomes, for which randomised controlled trials (RCTs) were most informative.

Table 1 Screening and monitoring interventions reviewed in this paper

Results

Identification and care of high-risk pregnancies

Pregnancy risk screening

Background

Early identification of high-risk pregnancies can theoretically facilitate monitoring, referral and prompt initiation of therapy. Multiple screening and scoring systems have been developed to assess obstetric risk generally [5, 6], as well as the risk of preterm labour, Caesarean delivery, and other maternal and fetal outcomes. Risk scores using these systems can range from simple additive scores to the products of more complex multivariable models that quantify risk factors according to their association with adverse outcomes [7]. An effective risk screening system, particularly if convenient to implement and relatively non-dependent on diagnostic technologies, would be particularly useful in low-resource settings to help providers identify high-risk pregnancies and refer them for appropriate facility-based care, and to help facilities allocate scarce resources.

Literature-based evidence

Ten observational studies met our inclusion criteria; none tested interventions for pregnancies scored as high-risk (Table 2). Most risk scoring systems were originally developed and tested in high-resource settings. At a national hospital in New Zealand, Pattison et al. [8] developed and tested an antepartum risk scoring system (N = 29,101 consecutive pregnancies) using prior obstetric history and current pregnancy risk factors, where a fetal risk score ≥ 3 denoted high risk. One-third of the total population (N = 10,859) was scored as high-risk, and 90% of those who had a perinatal death were identified using the scoring system. Women with an antepartum risk score of 7 or more (very high risk) had a perinatal mortality rate of 200/1000, whereas the low risk group of 18,242 (63%) had a perinatal mortality rate of 4.1/1000. The system clearly identified the population at risk of fetal or early neonatal loss, but could not effectively predict the need for intervention, as 60% of the low-risk group had a complicated pregnancy requiring intervention [LOE: 2-]. The same research group later used this dataset to develop a statistically derived antenatal risk scoring system using data on 27 antenatal variables from 20,985 pregnancies [9]. Tested on 3120 subsequent pregnancies, the scoring system had a positive predictive value of 0.73 in early pregnancy and 0.91 at onset of labour. Although only 16% of pregnancies were classified as high-risk at onset of labour, 87% of adverse outcomes occurred within this group. The positive predictive value of this system was higher than any previously reported statistically derived score, but requires that clinicians be able to sum logistic coefficients (basic statistical analysis), which requires more training than some other systems [LOE: 2-].

Table 2 Impact of pregnancy risk screening on stillbirth and perinatal mortality

In the UK, an effort by Chard et al. [10] to calculate obstetric risk scores from individual risk factors (N = 2029 pregnant women) found that risk scores were useful only for identifying the small group of women at particularly high risk of adverse fetal outcomes. For most women, risk scores were uninformative [LOE: 2-].

In the USA, Morrison et al. [11] found that perinatal mortality was significantly higher in the high- versus the low-risk groups identified with the application of a simplified risk scoring system, where high risk was a score of 3 or greater (69/1000 versus 7/1000, respectively, P < 0.0001). Seventy percent of perinatal deaths occurred in the high-risk group, which was 19% of the total group screened [LOE: 2-].

Other studies implemented risk scoring systems in more remote or low-resource settings in low-/middle-income countries. Attempting to predict intrapartum complications in rural Zimbabwe where most women receive care from nurse-midwives, Majoko et al. [12] employed antenatal risk assessment at the first antenatal visit based on medical and demographic measures and obstetric history (N = 5223 women at 12 health centres). All high-risk women (N = 2890) were encouraged to seek hospital delivery. Of the 924 (17.7%) women who experienced complications, 577 (62.4%) had had risk markers identified at booking; however, only 20% (577/2890) classified as high risk developed intrapartum complications. This risk screening system had a likelihood ratio of 1.16, indicating it was ineffective in identifying women at risk of pregnancy complications and generated too large a risk group for referral [LOE: 2-].

In India, Talsania et al. [13, 14] reported on the application of an antenatal risk scoring system (N = 687 women), and observed that no stillbirths occurred among women with no identified risk factors, whereas among women in the highest risk group, 20% had stillbirths. Perinatal mortality was 84.77/1000 births, and 7.94 among the no risk group. The perinatal mortality rate rose with level of risk, with a rate of 92.20/1000 births for the women with mild risks to a rate of 200/1000 for those with severe risks, which was statistically significant. Sensitivity, specificity, and positive predictive values for perinatal mortality were 98.3%, 19.9%, and 10.3%, respectively [LOE: 1+].

In a rural primary care setting in the USA, Lefevre et al. [15] found a clear relationship between risk score and probability of adverse outcome, but cautioned that good sensitivity could be achieved only with a very high false-positive rate, as the majority of adverse outcomes occurred in women identified as low-risk [LOE: 2-]

In a remote area of Australia, Humphrey et al. [16] employed pregnancy risk scoring (N = 2875 women with singleton births), and found that during the study period, hospital and regional perinatal mortality rates fell by more than half. Women with low-risk scores had a statistically significantly lower incidence of preterm birth, leading the authors to conclude that risk scoring can be of benefit in allocating scarce resources [LOE: 2-].

Several other retrospective analyses attempted to associate perinatal mortality with the presence of specific risk factors. In Guadeloupe, West Indies, using data from the 1984–85 Guadeloupean Perinatal Audit, de Caunes et al. [17] observed that perinatal mortality was associated with a specific combination of risk factors representing maternal demographic, socioeconomic, obstetric history and risk characteristics measurable at the first antenatal visit, leading the authors to advocate for risk assessments specific to pregnancy outcomes within specific populations [LOE: 3].

Using risk screening as a strategy to facilitate monitoring and referral, Abraham et al. [18] adapted the Home Based Mothers Card recommended by the World Health Organisation (WHO) for a rural Indian setting. Perinatal mortality was directly associated with number of risk factors: perinatal mortality rates (PMRs) were higher among women with 3 or 4 risk factors than those with 1 or 2 risk factors [LOE: 2-].

Conclusion

A number of studies reviewed were able to successfully identify women at high risk of obstetric complications. However, despite good sensitivity, risk scoring systems [7] have poor positive predictive value in anticipating adverse birth outcomes, particularly when used well before term or in populations significantly different from the population in which the system was developed [19]. This limitation of risk scoring systems limits the impact of their use. No studies were found that effectively incorporated risk screening with appropriate interventions to demonstrate a possible impact on stillbirth or perinatal mortality rates compared to a control group. The evidence for risk screening at the community level yielded a Grade C assessment.

Fetal movement counting

Background

Monitoring fetal movements using counting strategies is an indirect measure of central nervous system integrity and fetal responsiveness. Commonly employed in clinical practice, fetal movement counting is a simple and inexpensive means of monitoring fetal well-being [20]. The rationale for fetal movement counting is that decreased fetal movements signal decreased oxygenation, which often precedes fetal demise [1]. Kick charts or other recording strategies involve a pregnant woman in the second half of pregnancy monitoring fetal movements, documenting the frequency of movements she feels, and reporting these counts to her physician. Changes in these counts, particularly decreases, indicate possible fetal compromise, and thus alert care providers to the need for further diagnostic tests such as non-stress testing or the biophysical profile. Cessation of movement can indicate impending fetal death, while gradual diminishment of activity can indicate chronic fetal compromise [21]. Fetal movement monitoring may be used routinely, or only in high-risk pregnancies. There are many different counting methods, and fetal movement monitoring has a wide following among clinicians, who perceive the practice to serve as an early warning system for fetal compromise. A criticism of the practice is that it may cause undue worry for the pregnant woman [22].

Literature-based evidence

The literature search identified one Cochrane review comprised of three RCTs; and seven observational and intervention studies (Table 3).

Table 3 Impact of fetal movement counting on stillbirth and perinatal mortality

Several trials in high-risk pregnancies documented an association between poor fetal movements and stillbirth/perinatal mortality rates. A trial among high-risk women (N = 110) by Lema et al. [23] found that fetal movement was a predictor of stillbirth rate, documenting differential rates [12/1000 (1/83) versus 185/1000 (5/27) in the groups with good versus poor fetal movements, respectively] [LOE: 2-]. De Muylder [24] evaluated the use of a kick chart to monitor the fetus in high-risk pregnancies, finding that both stillbirth rates (SBR) and PMR increased significantly if a previously normal chart kick chart became abnormal (antepartum SBR = 194/1000 versus 7/1000; and PMR = 222/1000 vs. 27/1000 in charts that became abnormal versus normal, respectively, P < 0.001) [LOE: 2-]. Two other observational studies found no difference in perinatal mortality between groups with good versus poor fetal movements measured using kick charts [25, 26].

Other observational studies, RCTs, and reviews assessed impact on perinatal mortality of interventions using kick charts. A before-after study by Moore et al [27] introduced formal fetal movement monitoring into clinical practice, and stillbirth rates declined from 8.7 to 2.1/1000 over the course of the study (χ2 = 6.8; P < 0.01). A Cochrane review by Mangesi and Hofmeyr [22] included 3 trials that tested strategies of routine kick counting, but varied study designs precluded outcome pooling (Additional file 1). Unfortunately, no included trials compared fetal movement counting with no fetal movement counting, and all studies showed nonsignificant impact on perinatal outcomes, including stillbirth incidence. [LOE: 1++].

The largest RCT testing kick charts [28] assessed the impact of the use of kick charts on unexplained stillbirth in normally-formed singleton pregnancies (N = 68654), and found no difference in rates of fetal death between intervention and control groups (59/31993 [2.9/1000] versus 58/36661 [2.7/1000], respectively [NS]). These findings alone largely shaped the UK National Institute for Health and Clinical Excellence (NICE) evidence-based routine antenatal care guidelines, which do not recommend the use of kick charts in uncomplicated pregnancy [29][LOE: 1+]. However, of the 17 women in the study randomised to kick charts who alerted their provider about decreased fetal movement and subsequently delivered a stillborn baby, none had an emergency delivery, as follow-up testing using cardiotocography resulted in false negatives for all 17 women[30].

Conclusion

The existence of a Cochrane review of multiple RCTs [22] yields a Grade B evidence rating. In keeping with the NICE guidelines based largely on 1 study [28], evidence from these studies indicates a lack of impact of fetal movement monitoring on stillbirth or perinatal mortality. Despite indirect evidence that formal movement monitoring using a counting method is more effective than mothers' subjective assessments of fetal movement in identifying babies at risk of intrauterine death, false negatives on subsequent fetal assessment tests and clinical error may be responsible for the lack of impact on perinatal mortality, as suggested by Del Mar et al [30]. Monitoring does appear to be of some value in high-risk pregnancies [23, 24], particularly those in which there is suspicion of placental insufficiency. Routine fetal movement monitoring is currently recommended only for high-risk pregnancies, particularly those in which there is clinical suspicion of restricted fetal growth or placental dysfunction revealed through ultrasonographic or Doppler studies. Further studies are warranted to determine which methods of fetal movement counting prove most effective in identifying complications (sensitivity and specificity) early enough for interventions to prevent stillbirth, as well as acceptability to and feasibility for women. Universal fetal movement monitoring for all pregnancies is unsupported by scientific evidence.

Routine use of ultrasound scanning

Background

Ultrasound scans during pregnancy are widely used, even in many resource-poor settings, but availability and quality of ultrasound machines vary, and ultrasound operators in some settings may lack the ability to accurately interpret imaging. Diagnostic ultrasound examination may be employed to date pregnancies, identify multiple pregnancies, document placental location, identify fetal anomalies (particularly when the fetus is suspected to be at high risk of malformation), identify fetal growth restriction or abnormal amniotic fluid volume, or to investigate clinical complications (e.g., bleeding). Some clinicians have postulated that routine use of ultrasound in all pregnancies could identify problems in asymptomatic pregnancies, whether early or late in gestation [31].

Literature-based evidence

We identified two Cochrane reviews and five other intervention/observational studies; we also conducted an independent meta-analysis incorporating 9 RCTs (Table 4).

Table 4 Impact of use of routine ultrasound scanning on stillbirth and perinatal mortality

One observational study of routine ultrasound use suggested that ultrasound may help to identify some high-risk pregnancies. In Egypt, Mahran et al [32] reported that routine ultrasound was superior to fundal palpation in identifying fetal growth restriction (89.7% versus 34.7% of growth-restricted infants identified accurately with each method, respectively). No observational studies reported any statistically significant impact of routine ultrasound scanning on subsequent stillbirth rates. A Cochrane review on the impact of ultrasound during pregnancy is in progress [33].

Another Cochrane review by Neilson [31] reviewed adequately controlled trials of routine ultrasound imaging in early pregnancy (N = 9) (Additional file 2). The study found that routine ultrasound examination was associated with earlier detection of multiple pregnancies and reduced rates of induction of labour for post-term pregnancy, but ultrasound had no impact on PMR [Odds ratio (OR) = 0.86, 95% confidence interval (CI): 0.67–1.12], even in twin pregnancies, despite generally earlier diagnosis in the ultrasound-screened pregnancies. Where detection of fetal abnormality was a specific aim of the examination, ultrasound was associated with increased terminations of pregnancy [LOE: 1+]

A second Cochrane review by Bricker et al. [34] assessed the impact of ultrasound in late pregnancy (8 RCTs, N = 27,024 women) and found no difference in antenatal, intrapartum and neonatal intervention or morbidity in those undergoing ultrasound screening versus those not screened (Additional file 3). The Caesarean section rate was slightly higher among the screened group, but this difference did not reach statistical significance. Routine late pregnancy ultrasound was not associated with improvements in overall perinatal mortality.

An additional RCT (N = 1528 women) from New Zealand by Duff et al. [35] documented a statistically non-significant increase in SBR among women scanned twice during pregnancy, at 16–24 weeks and again at 32–36 weeks gestation [LOE: 2+]. In another RCT by Proud et al [36] where placental grading information from ultrasound screening was either given to a clinician (intervention) or withheld (controls), the antepartum SBR (excluding lethal malformations) was 0/1014 versus 9/1011 among intervention versus controls, respectively (P < 0.05) [LOE: 2+].

New meta-analysis

We also conducted an independent, new meta-analysis for the purposes of this review, as we identified 9 RCTs (N = 35,049 women) reporting an impact on perinatal mortality rate of ultrasound in early pregnancy versus no or selective use of ultrasound in early pregnancy (before 24 weeks) (Figure 1). We found no significant difference between the 2 groups when the results were pooled (OR = 0.89, 95% CI: 0.70–1.14).

Figure 1
figure 1

Forest plot of results of meta-analysis of perinatal mortality rates in women examined by routine vs. selective ultrasound in early pregnancy.

Conclusion

There is no clear evidence that ultrasound examination during pregnancy is harmful [31], and its assumed benefits include (1) better gestational age assessment; (2) earlier detection of multiple pregnancies; (3) determination of placental location to rule out placenta praevia; (4) detection of clinically unsuspected fetal malformation when termination of pregnancy is more feasible, and (5) monitoring of fetal growth for pregnancies at increased risk of fetal growth restriction or macrosomia. The reduced incidence of induction of labour for apparent post-term pregnancy in the routinely scanned groups presumably results from better gestational age dating, and twin pregnancies being detected earlier. Neither of these effects has been shown to improve fetal outcome, but much larger numbers of participants would be required to accurately measure this outcome.

Based on the results of 2 Cochrane reviews, our meta-analysis, and other RCTs (overall Grade B evidence), there is no evidence that routine ultrasonography has any impact on perinatal mortality compared to the selective use of ultrasonography based on clinician judgement. It may be that routine ultrasound cannot reliably detect complications, or that high rates of false positives expose higher numbers of babies to iatrogenic intervention (particularly the risk of iatrogenic preterm birth in the event of inaccurate gestational age dating). The routine use of early ultrasonography in pregnancy cannot be recommended to prevent stillbirth, as there is no evidence of its benefit in preventing stillbirth or perinatal mortality. There is a need for decision analysis studies subsequent to diagnostic ultrasound, like the study of indicated Caesarean section for fetal macrosomia diagnosed by ultrasound by Rouse et al [37], but which report perinatal mortality outcomes. Clinics and hospitals, particularly those in resource-constrained settings, must assess whether the potential benefits are worth the cost of routine ultrasound screening for all pregnant women.

Doppler velocimetry

Background

In many high-income countries, Doppler ultrasound studies are used as a non-invasive means to assess the sufficiency of uterine and umbilical cord blood flow. These velocimetry studies can improve management of pregnancies by aiding identification of fetuses at highest risk of adverse outcomes associated with pre-eclampsia, fetal growth restriction, and congenital malformations. Management of pre-term pregnancies with signs of fetal growth restriction and pre-eclampsia is complex, especially before 32 weeks gestation. The risk of prolonged hypoxia and acidaemia leading to stillbirth or neonatal death if the pregnancy is allowed to progress must be balanced against the risks of neonatal morbidity and mortality associated with prematurity if early delivery is chosen. Doppler ultrasonographic evaluation may aid determinations of the degree to which the fetus may be or become compromised.

Early in normal pregnancy, trophoblasts invade the maternal uterine spiral arteries and reduce resistance to uterine blood flow. Impeded flow measured by uterine artery Doppler suggests a failure of this trophoblastic invasion, which is associated with subsequent pre-eclampsia, fetal growth restriction, and stillbirth [38]. Uterine artery Doppler studies could therefore be helpful in identifying women likely to develop pre-eclampsia or to have a growth-restricted fetus [39].

Observational Doppler studies of the umbilical artery, first conducted in the 1970s, consistently showed a correlation between extremely abnormal waveforms and adverse outcomes, including fetal growth restriction and stillbirth [40–42]. In growth-restricted fetuses, results of umbilical and fetal Doppler waveform analyses suggest progressive severity of fetal compromise [38, 43]. Initially, umbilical artery velocity waveforms show increased resistance; subsequent deterioration is indicated by absent or even reversed end diastolic flow in the umbilical artery. Later, fetal middle cerebral artery flow shows decreased resistance, indicating brain sparing, and eventually, abnormal venous Doppler results (ductus venosus waveforms and umbilical vein pulsatility) suggest fetal cardiac dysfunction. Consequent central nervous system damage then manifests as non-reactive results to fetal tests of well-being, but there is wide variability in the timeline of fetal progression to severe compromise [38, 43].

Despite these well-established markers of fetal compromise in Doppler testing, it is not clear whether abnormal results of different modalities of Doppler ultrasound lead to improved perinatal outcomes and prevention of stillbirths, nor are the most appropriate indications and timing of testing known. Additionally, if a fetus is not seriously compromised, Doppler ultrasound may potentially cause iatrogenic harm in suggesting the need for inappropriate early delivery.

Literature-based evidence

The literature search identified three systematic reviews, one Cochrane protocol, and 10 other intervention/observational studies (Table 5 and Table 6).

Table 5 Impact of uterine artery Doppler velocimetry on stillbirth and perinatal mortality
Table 6 Impact of umbilical artery and ductus venosus Doppler velocimetry on stillbirth and perinatal mortality

Uterine artery Doppler waveform analysis

Several studies assessed whether uterine artery Doppler velocimetry in unselected populations could identify high-risk pregnancies, particularly those at risk of stillbirth. In a systematic review, Papageorghiou et al [44] reviewed 15 studies of routine Doppler assessments in pregnancy in unselected populations, and found that increased impedance to uterine artery flow was associated with increased risk of pre-eclampsia, fetal growth restriction and perinatal death, and that Doppler diagnosis of impeded artery flow appropriately identified ~40% of women who subsequently developed pre-eclampsia (6-fold increased risk with positive Doppler) and ~20% of fetal growth restriction cases (3.5-fold increased risk) [LOE: 1+](Additional file 4).

Smith et al [45] reported a statistically significantly increased risk of antepartum stillbirth among women whose uterine artery Doppler flow velocimetry at 22–24 weeks had a pulsatility index in the top decile [adjusted Hazard Ratio (HR) = 5.5, 95% CI: 2.8–10.6] and among those with a bilateral notch (adjusted HR = 3.9, 95% CI: 2.0–7.8), compared with controls with normal Doppler flow [LOE: 2-].

An intervention RCT attempting to use Doppler in interventions to reduce rates of pre-eclampsia in France and Belgium by the Essai Régional Aspirine Mère-Enfant (ERASME) Collaborative Group [46] randomised women to either uterine Doppler (N = 1253) or placebo (N = 617). Women with abnormal waveforms in the intervention group were given low-dose aspirin to prevent pre-eclampsia; but despite the aspirin prescription, rates of pre-eclampsia were similar in the Doppler and placebo groups (28/1237 [2.3%] versus 9/616 [1.5%], respectively; RR = 1.55, 95% CI: 0.7–3.3 [NS]). The study found a non-significant elevated impact on perinatal mortality among Doppler-assessed fetuses compared to those whose mothers were given placebo (RR = 4.02; 95% CI: 0.5–32.0 [NS]).

Umbilical artery and venous Doppler waveform analysis

Baschat et al [47] performed umbilical artery and venous Doppler velocimetry in preterm growth-retarded fetuses (N = 224) to evaluate whether absent or reversed umbilical end-diastolic velocity, absence or reversed atrial systolic blood flow velocity in the ductus venosus, or pulsatile flow in the umbilical vein could predict stillbirth or perinatal death before 37 weeks' gestational age. Logistic regression analysis showed that umbilical artery waveform analysis was the Doppler application most predictive of perinatal mortality (R2 = 0.49, P < 0.001) and stillbirth (R2 = 0.48, P < 0.001). In fetuses with absent or reversed umbilical end flow, prediction of asphyxia and stillbirth was significantly enhanced by venous Doppler. Umbilical artery waveform analysis offered the highest sensitivity and negative predictive value, whereas ductus venosus and umbilical vein flow studies had the best specificity and positive predictive values for perinatal death [LOE: 1+].

Using personal computer-based, continuous-wave Doppler machines to assess umbilical artery flow velocity waveforms in women referred for suspected fetal growth restriction, Hugo et al. [48] found a direct association between resistance indices (RIs) and perinatal mortality rate (PMR) (PMRs of 13.2, 39.1 and 41.7 for women with RIs < P75, P75-95 and > P95, respectively) [LOE: 3].

Baschat et al. [49] conducted a review of studies (N = 8) where umbilical artery and ductus venosus Doppler studies were used to make decisions regarding delivery timing in pre-term growth-restricted fetuses (Additional file 5). One analysis in the review compared outcomes among fetuses with normal ductus venosus indices (N = 302) with fetuses with elevated ductus venosus index (N = 202), of whom N = 101 had absent or reversed umbilical end-diastolic flow and N = 34 had absence or reversal of atrial velocity in the ductus venosus. Perinatal mortality was 5.6% (16/282) among fetuses with normal Doppler, versus 11.9% (12/101) with absent or reversed umbilical end-diastolic flow, 38.8% (64/165) with abnormal ductus venosus index and 41.2% (7/17) with reversed atrial velocity in the ductus venosus. Abnormal ductus venosus results (N = 3 studies) effectively identified fetuses at risk of stillbirth at least 1 week prior to delivery, independent of umbilical artery waveform results, though questions remain about optimal delivery timing in growth-restricted pre-term fetuses [LOE: 1+].

Recently, researchers have focused on downstream impact on perinatal mortality of the use of umbilical artery Doppler ultrasound followed by appropriate interventions for the identified conditions. A Cochrane review by Neilson and Alfirevic [50] reviewed 11 RCTs (~7000 women) of Doppler ultrasound investigating umbilical artery waveforms in high-risk pregnancies. Compared to no Doppler ultrasound, evaluation with umbilical artery Doppler ultrasound in complicated pregnancies (especially with hypertension or presumed growth restriction) was associated with a non-significant trend toward lower perinatal mortality (OR = 0.71, 95% CI: 0.50–1.01) and stillbirth risk (OR = 0.79, 95% CI: 0.46–1.34), as well as significantly fewer inductions of labour (OR = 0.83, 95% CI: 0.74–0.93) and hospital admissions (OR = 0.56, 95% CI: 0.43–0.72) (Additional file 6). Whether a woman had received Doppler ultrasound was unassociated with fetal distress in labour or Caesarean section rates [LOE: 1+]. A Cochrane protocol by Alfirevic et al indicates that a review is in progress to assess whether the use of umbilical artery, middle cerebral artery, and ductus venosus Doppler velocimetry improves subsequent obstetric care and fetal outcome [51].

Umbilical artery Doppler alone may not be any more effective than routine ultrasonography in some diagnostic assessments of fetal growth. An RCT of Doppler in twin pregnancies in New Zealand, Australia and Southeast Asia where all pregnancies were studied ultrasonographically to monitor fetal growth showed no statistically significant difference in perinatal mortality between groups on which umbilical artery Doppler was performed versus those with no Doppler [52].

Conclusion

Doppler ultrasound is a relatively new technique that has been applied to the study of fetal, placental and uterine circulatory dynamics. Despite its novelty, it has been evaluated by more RCTs than has any other biophysical test of fetal growth or well-being. In low-risk or unselected populations, there is little evidence that any form of routine Doppler velocimetry contributes to reductions in stillbirth rates (overall Grade C evidence). This lack of impact may be complex: Doppler ultrasound may not identify a sufficient proportion of flow abnormalities to measurably impact stillbirth incidence; Doppler-detected abnormalities may not be subsequently monitored appropriately with other tests of fetal well-being and serial Doppler testing; intervention based on abnormal Doppler may not work; or high rates of false-positives may unnecessarily expose the fetus to the risk of preterm birth, particularly if gestational age dating is inaccurate. Additionally, most existing studies are underpowered to detect small impacts on perinatal or maternal outcomes.

Uterine artery Doppler waveform analysis accurately identifies compromised fetuses at risk of stillbirth, especially in cases of placental underperfusion associated with pre-eclampsia and/or growth restriction, but no studies have shown any ability of subsequent intervention to prevent stillbirth. More studies are needed into the optimal timing of monitoring and intervention in cases of abnormal uterine artery waveforms.

Of all Doppler diagnostic studies of the fetus, umbilical artery and ductus venosus Doppler velocimetry are most predictive of fetal compromise associated with fetal growth restriction, and there is some evidence that timely and appropriate intervention for abnormal umbilical artery or ductus venosus waveforms can prevent stillbirths [53]. More evidence should soon be available: in addition to the Cochrane review of umbilical and fetal Doppler velocimetry, results are forthcoming of the multi-centre Trial of Umbilical and Fetal Flow in Europe (TRUFFLE) group, an RCT of timing of delivery in early pre-term fetal growth restriction based on early and late fetal Doppler venous changes versus cardiotocography. Such studies may shed light on the most appropriate and effective methods of fetal surveillance and optimal uses of Doppler velocimetry, including multi-vessel analysis [54].

Further studies are needed to assess whether such decision analytical models based on Doppler and other fetal surveillance findings for fetal growth restriction, pre-eclampsia, or congenital abnormalities could have any impact on stillbirths. Further research might also investigate other applications of Doppler velocimetry, including identifying women who should be given other screening tests, the comparative efficacy of Doppler versus other fetal surveillance methods, and contributing to the study of the pathophysiology of impaired placentation, uteroplacental and fetoplacental haemodynamics, and pre-eclampsia.

Pelvimetry

Background

Pelvimetry, or pelvic measurement in pregnant women with the intention of predicting likely cephalopelvic disproproportion of cephalic presentations (and thus their subsequent need for Caesarean section), can be performed by clinical manual examination, or with imaging techniques including conventional x-ray, computerised tomography scanning, or magnetic resonance imaging. Successful detection and management of cephalopelvic disproportion is thought to reduce the risk of obstructed labour and intrapartum stillbirth.

Literature-based evidence

We identified 1 Cochrane review and 1 other observational study of pelvimetry reporting perinatal outcomes (Table 7). The observational study by Fine et al [55] retrospectively analysed studies of x-ray pelvimetry (N = 100 trials) in cephalic presentations, comparing 3 prognostic indicators for vaginal delivery: the Thoms method, the modified Ball technique, and manual assessment. Neither pelvimetric method was significantly more accurate than manual assessment of the pelvis in predicting obstetric outcome, nor was any one method superior to the other.

Table 7 Impact of pelvimetry on stillbirth and perinatal outcomes

When implemented as part of a strategy of pregnancy management, pelvimetry appears to have no impact on stillbirth. A Cochrane review by Pattinson and Farrell [56] assessed RCTs implementing x-ray pelvimetry in cephalic presentations (N = 4 trials, N>1000 women). Pelvimetry was associated with increased rates of Caesarean section (OR = 2.17; 95% CI = 1.63–2.88) but had no impact on PMR (4 RCTs; OR = 0.51, 95% CI = 0.18–1.42 [NS]) [LOE: 1+](Additional file 7).

Conclusion

There is little support for the use of pelvimetry to predict the need for Caesarean section in women with fetuses with cephalic presentations, as the dynamic and individual nature of maternal tissue changes during labour and fetal head moulding in the birth canal make antenatal pelvimetry a poor predictor of cephalopelvic disproportion. The practice may result in inadvertent harm to the mother by significantly increasing her risk of having a Caesarean section, without increasing the benefit to fetus or neonate, as pelvimetry shows no impact on stillbirth incidence. However, deficiencies in the existing studies included in Pattinson's meta-analysis should be noted: Parsons [57] attributed the increased perinatal mortality and birth asphyxia reported by Crichton [58] to lack of availability of electronic fetal monitoring, not to cephalopelvic disproportion. Even more problematic, the 2 deaths documented by Richards [59] occurred in utero prior to labour, which imply that cephalopelvic disproportion was not implicated. Treatment allocation strategies in all trials were of poor quality.

Given the deficiencies in existing studies, it remains plausible that other forms of imaging could effectively diagnose true cephalopelvic disproportion and avert stillbirth via Caesarean section in these cases. We classified the overall evidence as Grade C and found no evidence in support of using pelvimetry for preventing stillbirths.

Detection and management of maternal diabetes mellitus

Background

In pregnant women, pre-existing diabetes mellitus can cause severe complications for both mother and child during pregnancy and delivery, including congenital malformations, hypertension, pre-eclampsia, macrosomia and intrauterine fetal death [60–63]. Macrosomia (large size for gestational age) increases the risk to the fetus of birth trauma, including shoulder dystocia, bone fractures and brachial plexus injury, in addition to obstructed labour. Good metabolic control in the mother from prior to conception through the postpartum period reduces the risk of these complications [64–66]. Because pre-gestational diabetes is a known risk factor for stillbirth, women with this condition are usually offered intensive surveillance and management during pregnancy, which may include glycaemic control efforts through diet, exercise, and/or insulin therapy with glucose monitoring, frequent fetal surveillance using tests of fetal well-being, and/or induction at or before term. Despite widespread practice of this protocol, a recent UK study demonstrated a 4-fold higher rate of stillbirth among women with pre-gestational diabetes compared to non-diabetic women, with 83% of stillbirths unrelated to congenital malformations [60].

There is also substantial confusion surrounding optimal screening for and management of glucose intolerance and gestational diabetes. Gestational diabetes and impaired glucose tolerance are relatively common and, like pre-gestational diabetes, have been linked with adverse perinatal outcomes including stillbirth and shoulder dystocia as a consequence of fetal macrosomia [67, 63, 68]. However, how to best screen for gestational diabetes is controversial. The American Diabetes Association, the American College of Obstetricians and Gynecologists, and the World Health Organization recommend universal screening for gestational diabetes based on the conclusion that selective screening is inadequate [69–72], while the US Preventive Services Task Force concluded that there is insufficient evidence of benefit to justify universal screening for gestational diabetes. As with management of pre-gestational diabetes, intensive management of gestational diabetes includes glucose monitoring, dietary regulation, and tests of fetal well-being. The need for insulin therapy is usually less for gestational diabetes than with pre-gestational diabetes.

Literature-based evidence

Our literature search identified 4 reviews and 12 other intervention and observational studies reporting perinatal outcomes after management of women with any form of diabetes mellitus (Table 8).

Table 8 Impact of detection and management of maternal diabetes mellitus on stillbirth and perinatal mortality

Intensive management

Tuffnell et al. [73] undertook a systematic review of RCTs (N = 3) of strategies for intensive management of women with gestational diabetes and/or impaired glucose tolerance in pregnancy (N = 223), including obstetric monitoring, dietary regulation, and insulin therapy in some cases. No trials of treatments for gestational diabetes were included, however, and of the trials of treatments for impaired glucose tolerance that reported perinatal outcomes, only 1 trial (N = 68) of mostly Hispanic patients reported birth trauma incidence. This study found no significant difference between the group receiving intensive management versus any minimal treatment (RR = 0.37, 95% CI: 0.02–8.86 [NS]). Caesarean section rates were not significantly different [LOE: 1+].

A number of studies compared different strategies of management of diabetic pregnant women, including glycaemic monitoring and control, diet and exercise regimens, and insulin treatments. In a prospective population-based study of intensive management of women with diabetes mellitus (N = 1145), Langer et al [74] observed that an intensively managed group of women with diabetes had rates of stillbirth and neonatal complications similar to non-diabetic controls (N = 4922), while diabetic women given conventional management (N = 1316) had higher rates of these adverse outcomes [LOE: 2+]. Crowther et al. [75] randomly assigned women with gestational diabetes to receive either dietary advice, blood glucose monitoring, and insulin therapy as needed, or routine care, and reported decreased perinatal mortality associated with the intervention compared to the routine care group (0 versus 5 perinatal deaths in intervention versus routine care groups, respectively, P = 0.07) [LOE: 1-](Additional file 8).

In the US, Gonzalez-Quintero et al. [76] conducted an observational study to assess the impact on perinatal outcomes of glycaemic control among women with gestational diabetes attending an outpatient gestational diabetes management programme. Over one-third of the participants in the group with poor glycaemic control had at least one of the factors in the composite study outcome variable (macrosomia, large-for-gestational-age, hypoglycaemia, jaundice, or stillbirth) compared with only 24% in the well-controlled group (P < 0.001) [LOE: 2-]. A somewhat less rigorous intervention study in India (N = 240 mothers) by Banerjee et al. [77] sought to assess the incidence of fetal complications in both gestational and pre-gestational diabetic pregnant women with tight versus acceptable or uncontrolled glycaemic control. In women with pre-gestational diabetes, the tight glycaemic control group had the lowest perinatal mortality (4.16% versus 18.8% versus 22.2% in tight, acceptable, and uncontrolled glycaemic control groups, respectively). In women with gestational diabetes, the same trend was noted with even greater impact of tight glycaemic control (0% versus 20% versus 40% in tight, acceptable, and uncontrolled glycaemic control groups, respectively). No statistical significance measures were provided [LOE: 1-].

In the US, McElvy et al. [78] conducted an evaluation of a programme that worked to achieve strict glycaemic control before and during early pregnancy in women with pre-gestational diabetes (N = 306), with intensive antepartum surveillance from 32 weeks gestation until delivery. Perinatal mortality declined steadily from 3% before the programme to a rate comparable to general population levels after completion of the programme [LOE: 1-]. In Soweto, South Africa, Huddle et al [79] reported that a programme involving gestational diabetic women given special services during pregnancy observed lower rates of perinatal mortality among women participating in the service compared to non-users of the service (3.7% versus 15.6%, respectively), but no statistical data was furnished [LOE: 3].

A descriptive study by Landon et al. [80] of non-stress testing (with delivery for non-reactive tests) in women with pre-gestational diabetes found no differences in glycaemic parameters in women delivered for suspected fetal compromise compared to a non- intervention group, suggesting the possibility that glycaemic control was unrelated to fetal compromise [LOE: 3].

Several studies assessed the impact on perinatal outcomes of mode of insulin treatment. Mukhopadhyay et al. [81] conducted a meta-analysis of RCTs (6 trials) comparing the impact of continuous subcutaneous insulin infusion versus multiple-dose insulin on glyacemic control and pregnancy outcome in diabetic women. Neither glycaemic control nor pregnancy outcomes were different between treatment groups [LOE: 1++](Additional file 9). In Israel, Hod et al. [82] conducted a small RCT (N = 322 women) comparing the impact on fetal and perinatal outcomes of insulin aspart, a fast-acting insulin analogue, versus human insulin therapy in women with pre-gestational diabetes. A slight trend toward lower perinatal mortality was observed in the insulin aspart group compared to the human insulin group (14/1000 versus 22/1000, respectively), but no statistical significance data was reported [LOE: 1-]. A study of insulin therapy using either pump infusion or split-dose therapy found no difference in rates of perinatal mortality in the treated groups compared to non-diabetic controls [83].

Elective delivery

A Cochrane review by Boulvain et al. [84] assessed trials of expectant management versus elective delivery in term women with pre-existing diabetes mellitus; only 1 trial was included (N = 200), which documented no perinatal mortality in either group [LOE: 1+](Additional file 10).

Conclusion

While data from RCTs is scarce, the limited evidence, largely from clinical management of diabetic patients (Grade C evidence), suggests that pregnant women who do not have vascular complications and with good glycaemic control do not as a group have an increased risk of stillbirth above the general population [85]. In settings with poor access to care and high prevalence of gestational diabetes, perinatal mortality has been shown to be reduced with diabetes screening and treatment [79]. Although retrospective studies reveal declines in the incidence of stillbirth among diabetic women in low-prevalence populations where diabetes care is available [86], few prospective trials have been able to show any impact on stillbirths or perinatal mortality, largely owing to the high sample sizes required for such studies [63]. Adequate glycaemic control and monitoring during pregnancy are a reasonable means for reducing stillbirths that has been shown to reduce many complications that may be related to stillbirth, including congenital anomalies and macrosomia. Where feasible, particularly in high-prevalence settings, large studies with rigorous designs may help confirm this recommendation.

Advanced monitoring in pregnancy

Antenatal fetal heart rate monitoring using cardiotocography

Background

Antenatal fetal surveillance studies are widely used to assess fetal well-being and to identify the compromised fetus. Fetal heart rate patterns are a principal component of the majority of tests of fetal well-being, and cardiotocography, where it is available, is the method frequently used to electronically record the fetal heart rate. In high-income countries, beginning in the third trimester, cardiotocographic monitoring (electronic fetal monitoring) has largely replaced intermittent auscultation (periodic listening to the fetal heart rate using a stethoscope or handheld Doppler device) for monitoring fetal heart rate. During the antenatal period, external cardiotocography is used, which employs a Doppler ultrasound transducer; the mother's uterine contractions are also monitored using a pressure transducer, with both transducers strapped to the mother's abdomen while recording is in process.

Antenatal fetal heart monitoring includes both non-stress tests (NST) and contraction stress tests (CST). Fetal heart rate patterns are classified as either reassuring (reactive), non-reassuring (non-reactive) or abnormal, considering heart rate baseline, variability, and decelerations. In high-income countries, particularly the US, the NST is widely accepted as a primary fetal surveillance tool in high-risk pregnancies. It may be used in combination with ultrasound testing to observe fetal movement and amniotic fluid indices. When an NST is non-reactive, its poor predictive value (< 50%) warrants confirmatory testing with CST or a complete BPP [87]. During a CST, uterine contractions are induced (usually with intravenous oxytocin, but contractions can be generated using nipple stimulation) and subsequent fetal heart accelerations and decelerations are monitored to detect possible cases of uteroplacental insufficiency. It is important to note that antenatal fetal heart monitoring is gestational-age dependent; at 28 weeks' gestation, only about 60% of normally formed fetuses will have reactive non-stress testing due to immaturity of the fetal autonomic nervous system rather than placental insufficiency.

Variation between practitioners in interpretation of cardiotocographic tracings can potentially lead to inappropriate intervention, or false reassurance without appropriate intervention. Tracings are notoriously difficult to interpret, as fetal sleep patterns, labour progress, external stimuli, and opiate administration to the mother can alter fetal heart rate changes in the absence of fetal hypoxia or distress [2]. Additionally, as indications of fetal distress often indicate early delivery, the gestational age threshold at which antepartum testing is initiated will depend on an institution's ability to care for very preterm neonates, which, in general, is earlier in high-income settings than in lower-resource settings [21].

Literature-based evidence

We identified 1 Cochrane review and 4 observational studies testing the impact of antepartum cardiotocography (including both NST and CST) on perinatal outcomes (Table 9).

Table 9 Impact of antepartum cardiotocography on stillbirth and perinatal outcomes

Several studies described how well NST and CST results correlated with subsequent perinatal outcome. An RCT by Flynn et al [88] identified a significant association of NST tracings (N = 569 tracings, N = 300 patients) with stillbirths, neonatal deaths, fetal growth restriction, complications of intrauterine hypoxia, and low Apgar scores [LOE: 1+]. An observational study of high-risk pregnant women (N = 561) by Rayburn et al [89] assessed NST tracings within 1 week of delivery along with subsequent perinatal outcome. Perinatal mortality in patients with reactive NSTs was comparable to that of patients with no apparent antepartum complications (1/509 versus 6/1408, respectively), and significantly lower than among untested patients or patients with nonreactive NSTs (20/1000 and 2/22, respectively, P < 0.05) [LOE: 2-]. Evertson et al [90] assessed the rates of fetal death within 1 week of negative CST results in a cohort of patients (N = 680), identifying only 7 deaths, of which most were due to factors other than placental insufficiency, suggesting that the test had low rates of false negatives.

A review by Pattison and McCowan [91] included 4 studies (N = 1,588 pregnancies) of the impact of cardiotocography use on perinatal mortality in high or intermediate risk pregnancies (Additional file 11). The trial reported a trend toward increased perinatal mortality in the cardiotocography group versus controls receiving no monitoring or whose cardiotocography results were concealed from the clinician; (3 trials, N = 1279 pregnancies, OR = 2.85, 95% CI: 0.99–7.12). Four of the 7 deaths in the largest trial reporting perinatal deaths were associated with fetal infection and prematurity, suggesting these deaths were not associated with the intervention. There was no increase in the incidence of elective Caesarean section or induction of labour [LOE: 1++].

Freeman et al [92] compared results from the NST (N = 1542 women) to the CST (N = 4626) for primary fetal surveillance and found a nearly 8-fold higher risk of antepartum fetal death in the NST group (7.8/1000 versus 1.1/1000, respectively, P < 0.05). Corrected for congenital anomalies and unrelated causes, the differential in antepartum fetal death remained 8-fold higher in the NST group (3.2/1000 versus 0.4/1000, respectively, P < 0.05) [LOE: 2+].

Conclusion

There are relatively few RCTs of antepartum fetal heart rate surveillance (Grade C evidence), though observational studies clearly indicate a correlation between non-reassuring cardiotocographic traces and adverse perinatal outcomes, including stillbirth. Although there is a Cochrane review on antepartum cardiotocography [91] showing a trend toward increased risk of perinatal mortality, the study was underpowered to detect such an impact, and the causes of the deaths observed appeared unlikely to have been preventable. While RCTs are lacking to evaluate an impact of NSTs in reducing stillbirth, apparent reductions in stillbirth rates have followed the incorporation of the NST into protocols for management of high-risk pregnancy in the United States [21]. As with fetal movement monitoring and umbilical Doppler velocimetry, the rate of false-positives with a non-reactive NST is high enough that additional testing, whether CST or BPP, is advised to guard against unnecessary intervention.

When used experimentally as a primary fetal surveillance tool, CST use was associated with lower rates of antepartum stillbirth [92], suggesting that it could be useful for primary fetal surveillance testing in pregnancies at highest risk of stillbirth, including those of women with hypertension, diabetes, and intrauterine growth restriction. As it typically uses intravenous oxytocin to stimulate uterine contractions, the CST is more technologically intensive than the NST and can induce labour; thus, it is contraindicated for patients with placenta previa, placental abruption, previous classical Caesarean section, and premature rupture of membranes [87]. The CST should be conducted cautiously in cases of multiple pregnancy, incompetent cervix, and polyhydramnios.

Fetal biophysical profile (BPP) test scoring for assessing high-risk pregnancy

Background

The BPP was conceptually derived from the Apgar score that is used to rate the condition of the newborn [93]. Using NST monitoring with cardiotocography and fetal ultrasound, the BPP collects 5 indicators of fetal well-being: fetal heart rate reactivity, breathing movements, gross body movements, muscular tone and qualitative amniotic fluid volume. Indications of fetal compromise often suggest the need for early delivery by induction of labour or Caesarean section.

Literature-based evidence

We identified one Cochrane review and four other observational studies of BPP reporting perinatal mortality outcomes (Table 10). A multi-institutional study in the US by Freeman et al [94] compared antepartum BPP versus NST, and reported that the fetal death rate among false negatives was several times lower among fetuses tested with BPP compared to the NST, though rates of false positive results with BPP were higher than with NST. Several other observational clinical studies were identified but had insufficient rigor or size to contribute meaningfully to the evidence base associating BPP results with stillbirth incidence [95–97].

Table 10 Impact of fetal BPP scoring on stillbirth and perinatal outcomes

Lalor et al. [1] undertook a Cochrane review of RCTs of variable quality (5 trials, N = 2839 women) comparing BPP with other forms of fetal assessment in women with high risk pregnancies (Additional file 12). There were no significant differences among pregnancies evaluated by the various methods of fetal assessment in perinatal mortality (RR = 1.33, 95% CI: 0.60–2.98) or Apgar score <7 at 5 minutes (RR = 1.27, 95% CI: 0.85–1.92) [LOE: 1+].

Conclusion

Compared with conventional fetal monitoring, which is based primarily on cardiotocography/NST, BPP appears to offer no improvement in pregnancy outcomes (Grade C evidence). Although rates of false negative test results of the BPP are low, rates of false positives are high. The total number of subjects included in the meta-analysis remains small (N = 2974), and some of the studies carry a high risk of allocation bias. Although there is no consensus on optimal protocol for fetal monitoring, studies demonstrate that it is reasonable to implement the modified BPP (which consists of an NST and amniotic fluid volume measurement only), with full BPP or other tests such as the CST reserved for abnormal test results [98]. This passive and rapid approach to monitoring has been shown to be more cost-effective without diminishing its predictive value [99]. For reasons of cost and simplicity, the modified BPP may also prove to be more implementable than the full BPP in low-/middle-income country contexts with ultrasound and cardiotocographic capacity [100, 101].

Vibroacoustic stimulation

Background

Adjunctive vibroacoustic stimulation with the NST is used less often than CST or BPP after non-reassuring NST results. Vibroacoustic stimulation provokes fetal response using a sound-emitting device placed on the maternal abdomen near the fetal head, along with simultaneous cardiotocography to document fetal movements and heart traces. Theoretically, the resultant startle reflex in the fetus and subsequent fetal heart rate acceleration or transient tachycardia following vibroacoustic stimulation provide reassurance of fetal well-being and minimise unnecessary intervention for nonreactive tests [102].

Literature-based evidence

Our literature search identified one Cochrane review on vibroacoustic stimulation and four other observational/interventional studies (Table 11). In a Cochrane review of vibroacoustic stimulation in conjunction with tests of fetal well-being (9 RCTs, N = 4838 women), Tan and Smyth [102] found that fetal vibroacoustic stimulation reduced the incidence of non-reactive antenatal cardiotocography tests (7 trials; RR = 0.62, 95% CI: 0.52–0.74) but the study was underpowered to detect impact on perinatal mortality of vibroacoustic stimulation compared to no or mock stimulation (RR = 0.32, 95% CI: 0.01–7.78 [NS]) [LOE: 1+](Additional file 13).

Table 11 Impact of vibroacoustic stimulation on stillbirth and perinatal outcomes

In Greece, Papadopoulos et al. [103] found no difference in fetal deaths in a group of women (N = 2833) randomised to vibroacoustic stimulation or no stimulation (10 [0.74%] versus 9 [0.6%], respectively [NS]). In India, Sood [104] conducted an RCT comparing vibroacoustic to mock stimulation and found no statistically significant difference in PMR (1.8% versus 2.9%, respectively; OR = 0.62, 95% CI: 0.05–5.57, P = 0.67).

New meta-analysis

We conducted a meta-analysis using available RCTs comparing outcomes (intrauterine or perinatal deaths) of pregnancies monitored by vibroacoustic stimulation compared to mock or no stimulation (4 trials, N = 1935 women in the vibroacoustic group, N = 2052 women in the mock or no stimulation group) (Figures 2 and 3). Three trials reported perinatal deaths and 1 reported intrauterine deaths, so the outcome of the meta-analysis was expanded and renamed as 'intrauterine or perinatal deaths' to include all 4 of the studies. We found no impact of vibroacoustic stimulation on intrauterine or perinatal deaths (RR [Fixed] = 0.98, 95% CI: 0.46–2.10 [NS]; RR [Random] = 0.99, 95% CI: 0.46–2.16 [NS]).

Figure 2
figure 2

Meta-analysis (Forest plot, Fixed effects model) of impact of vibroacoustic stimulation versus mock or no stimulation on intrauterine or perinatal deaths.

Figure 3
figure 3

Meta-analysis (Forest plot, Random effects model) of impact of vibroacoustic stimulation versus mock or no stimulation on intrauterine or perinatal deaths.

Conclusion

The benefits of using fetal vibroacoustic stimulation adjunctively with NSTs must be weighed with respect to the effect on the predictive reliability of the tests and the safety of the procedure. Vibroacoustic stimulation appears to offer maternal, fetal, and clinical benefits by decreasing the incidence of non-reactive cardiotocography and reducing the testing time. Although there are several RCTs and a Cochrane review evaluating vibroacoustic stimulation during pregnancy (Grade B evidence), the non-significant impact on perinatal mortality does not support including this intervention presently. Further RCTs are needed to determine optimal intensity, frequency, duration and position of vibroacoustic stimulation, as well as efficacy, predictive reliability, safety (in terms of fetal hearing impairment and neurological development) and perinatal outcome.

Amniotic fluid volume assessment

Background

Amniotic fluid protects and supports the fetus during pregnancy. Both low amniotic fluid (oligohydramnios) and high amniotic fluid (polyhydramnios) are abnormal and potentially place the fetus at risk of adverse outcomes. Oligohydramnios can be associated with maternal conditions including pre-eclampsia, or with placental membrane rupture, fetal growth restriction, post-term pregnancy, fetal kidney problems, or fetal or placental abnormalities [105, 106]. Polyhydramnios is frequently associated with maternal diabetes mellitus, maternal cardiac problems, twin-twin transfusion syndrome, or fetal or placental malformations, but in 50–60% of cases, it is idiopathic [107–110]. Until ultrasound became available, the invasive nature of amniotic fluid testing limited its clinical usefulness [111]. Using ultrasound, multiple methods for measuring amniotic fluid have been developed and are used to identify at-risk pregnancies. The amniotic fluid index (AFI) is a measure of the amount of amniotic fluid which is calculated by summing centimeters of depth of 4 different pockets of fluid; alternatively, the single deepest vertical pocket or maximum pool depth may be used. At term, many clinicians will induce labour or perform Caesarean section after diagnosis of decreased amniotic fluid volume to prevent an adverse pregnancy outcome. However, using assessments of amniotic fluid volume to predict fetal complications is controversial, and the utility of amniotic fluid assessment is different when used prior to versus after the onset of labour. Here, we examine the potential for assessment of amniotic fluid volume, or interventions to achieve normal amniotic fluid volume, to effectively detect high-risk pregnancy or fetal distress and subsequent adverse perinatal outcomes. We also examined the impact of interventions to achieve normal amniotic fluid volume on perinatal outcomes

Literature-based evidence

Our literature search identified two Cochrane reviews, one other review, and 15 other interventional or observational trials of amniotic fluid assessment to identify polyhydramnios or oligohydramnios that reported perinatal outcomes (Table 12 and Table 13).

Table 12 Impact of amniotic fluid assessment for polyhydramnios on stillbirth and perinatal mortality
Table 13 Impact of amniotic fluid volume assessment for oligohydramnios and associated interventions on stillbirth and perinatal outcomes

Polyhydramnios

Several observational studies explored the association of polyhydramnios with perinatal mortality, with inconsistent findings. Several observational studies [112] observed that polyhydroamnios was an independent risk factor for both perinatal mortality and intrapartum morbidity [LOE: 2-]. A retrospective cohort study by Dashe et al. [113] documented a fetal death rate of 4% in pregnancies with polyhydramnios diagnosed by AFI, of which 40% were unrelated to fetal malformations [LOE: 2-]. Magann et al. conducted a review of idiopathic polyhydramnios [107] including 4 studies that evaluated perinatal mortality with polyhydramnios after correcting for congenital anomalies. In the larger studies, idiopathic polyhyramnios was associated with macrosomia and a statistically significant 2- to 5-fold increase in the risk of perinatal mortality [LOE: 2+](Additional file 14). A retrospective logistic regression analysis of SGA and appropriate-weight fetuses with and without polyhydramnios determined that the combination of SGA and polyhydramnios was an independent risk factor for perinatal mortality compared to normal weight-for-age infants with normal AFI values (OR = 20.55; CI: 12.6–33.4) [114]. The association may not apply to certain subsets of high-risk pregnancies, as a similar study among women with gestational diabetes who had AFI performed antenatally found no elevated risk of perinatal morbidity or mortality among pregnancies complicated by polyhydramnios compared to gestational diabetics without polyhydramnios [LOE: 2-]. No intervention studies subsequent to diagnosis of polyhydramnios were identified.

Oligohydramnios

Observational studies of oligohydramnios cases demonstrated a consistent elevated risk of poor perinatal outcomes. Anandakumar et al. [115] studied how AFI used with non-stress cardiotocography and fetal acoustic stimulation for non-reactive NSTs might predict adverse pregnancy outcome in high-risk pregnancies (N = 565 women). Of the 4 perinatal deaths in the group with low AFI, 3 had had a reactive NST within 7 days of fetal death [LOE: 2-]. In Italy, Locatelli et al. [116] reported rates of oligohydramnios twice as high in pregnancies with poor perinatal outcome than pregnancies with no adverse outcome [LOE: 2-]. However, oligohydramnios identified during the intrapartum period did not appear associated with adverse perinatal outcome in high-risk pregnancies: Baron et al [117] observed that women with low AFI were more likely to have Caesarean section for fetal distress than women with normal AFI, but the rates of neonatal complications were similar [LOE: 2+].

One study found that in addition to the absolute volume of AFI, the distribution of amniotic fluid by intrauterine quadrants is predictive of fetal outcome. Myles et al. [118] observed higher rates of meconium staining, poor 1-minute Apgar scores, fetal heart decelerations, and fetal acidaemia in pregnancies where fluid volume was higher in the upper quadrants than in pregnancies where fluid volume was higher in lower quadrants [LOE: 2+].

A number of observational studies, RCTs and a systematic review compared AFI measurement to other methods of measuring amniotic fluid in ability to predict poor perinatal outcome. In an observational study in Egypt, Youssef et al. [119] (N = 174 women) found that the AFI was more sensitive than the single largest vertical pocket measurement in predicting perinatal mortality and multiple measures of perinatal morbidity. Morris et al. [120] documented similar findings, but the sensitivity of AFI < 5 cm for major adverse fetal outcome was only 28 percent. A Cochrane review [121] compared the evidence for the predictive value of 2 methods of amniotic fluid assessment (AFI versus single deepest vertical pocket) on adverse pregnancy outcomes (Additional file 15). Compiling the evidence from available RCTs (4 trials, N = 3125 women), the authors found that AFI versus single deepest vertical pocket led to significantly more cases of oligohydramnios being diagnosed (RR [Random] = 2.33, 95% CI: 1.67–3.24), more frequent labour induction (RR [Fixed] = 2.10, 95% CI: 1.60–2.76) and higher rates of Caesarean delivery for fetal distress (RR [Fixed] = 1.45, 95% CI: 1.07–1.97). They recommended that the single deepest vertical pocket measurement be used because AFI resulted in increased diagnoses of oligohydramnios and rates of labour induction with no improvement in perinatal outcomes compared to single deepest vertical pocket, suggesting better predictive value of single deepest vertical pocket. However, others have expressed concern that inter-observer reliability is lower with single deepest vertical pocket measurement (kappa = 0.33) compared to AFI (kappa = 0.72) [122]. An RCT by Alfirevic et al [123] randomised women to fetal monitoring by either AFI with computerised cardiotocography, or maximum pool depth determined by computerised cardiotocography, but found no statistically significant difference in perinatal outcome in the 2 groups. Another RCT by Oral et al [124] (N = 101 pregnancies) compared fetal monitoring (with cardiotocography) by either AFI or maximal vertical pocket. Measurement of maximal amniotic fluid vertical pocket proved slightly better than AFI in identifying post-term pregnancies with abnormal perinatal outcomes.

Only one intervention RCT compared AFI to no amniotic fluid assessment. Comparing AFI on admission (intervention) to no AFI (controls), Chauhan et al [125] found that women in the intervention group with a diagnosis of low AFI (measured as ≤ 5 cm or ≤ 5th percentile) were no more likely to have Caesarean section for fetal distress, neonatal acidosis, or Apgar score < 7 at 5 minutes than untested controls or women with normal AFI results; no perinatal mortality statistics were reported [LOE: 1+].

One intervention strategy to improve perinatal outcomes is to augment amniotic fluid volume in cases of oligohydroamnios. Hofmeyr and Gülmezoglu [126] undertook a systematic review of RCTs (2 trials, N = 78 women) assessing the impact of maternal hydration status (requesting that women drink 2 litres of water prior to a repeat ultrasound) on AFI (Additional file 16). In women with and without oligohydramnios, drinking water was associated with an increase in amniotic volume (WMD for women with oligohydramnios = 2.01, 95% CI: 1.43–2.60; WMD for women with normal AFI = 4.5, 95% CI: 2.92–6.08). Intravenous hypotonic hydration in women with oligohydramnios was associated with an increase in amniotic fluid volume (WMD = 2.3, 95% CI: 1.36–3.24), but isotonic intravenous hydration had no measurable effect.

Conclusion

Polyhydramnios is a clear risk factor for perinatal mortality, whether associated with congenital malformations, placental insufficiency, or of idiopathic origin. However, no studies reported the impact of interventions subsequent to a diagnosis of polyhydramnios after amniotic fluid assessment, so the impact on stillbirth of amniotic fluid screening for polyhydramnios remains unclear. Although robust RCTs are limited, very low AFI values (oligohydramnios) are frequently associated with poor pregnancy outcomes, and in these cases a reactive NST loses its usual reassuring value (Grade C evidence). Where feasible, amniotic fluid volume estimation may be helpful for identifying severe oligohydramnios, but further research is needed to document subsequent intervention and perinatal mortality outcomes to determine the cost-benefit ratio of utilizing amniotic fluid assessment procedures. Amniotic fluid assessment is complicated by high variability of sequential measurements and use of different measurement methods, which can compromise the accuracy of the test. No particular method of amniotic fluid volume assessment appears superior to another [123, 124], though using maximum vertical pool depth rather than AFI appears to limit unnecessary inductions of labour and Caesarean section by reducing diagnoses of oligohydramnios. There is a need for further research to test the impact of interventions to prevent or treat oligohydroamnios, particularly in the antepartum period with intact membranes, on perinatal outcomes.

Home versus hospital bed rest and monitoring for high-risk pregnancies

Background

Women with high-risk pregnancies, especially multiple pregnancies and pregnancies complicated by hypertensive disorders, are frequently admitted to hospital for bed rest and monitoring. However, in some instances, more limited monitoring in facilities and home-based bed rest or reduced physical activity may be as effective as hospital-based monitoring. Home-based activity modification, accompanied by outpatient surveillance and hospital admissions only for complications, would offer cost savings over hospital admission, reduced burden on hospital resources and personnel, and reduced disruption to the life of the mother posed by lengthy hospital stays.

Literature-based evidence

The literature search identified two Cochrane reviews and two other interventional studies comparing home-based versus hospital-based methods of care for high-risk pregnancies (Table 14). The first Cochrane review [127] assessed the effectiveness, in management of multiple gestations, of hospital-based bed rest versus home bed rest (reduced physical activity) with admission only for complications (6 RCTs, N>600 women, N>1400 infants) (Additional file 17). Hospital bed rest had no advantage compared to domiciliary bed rest in reducing perinatal mortality (OR = 0.89, 95% CI: 0.43–1.85), but birth weights were slightly higher in the hospitalised group. In the subset of trials of uncomplicated twin [128] and triplet [129] pregnancies, there was no advantage of hospital-based bed rest compared to non-hospitalised patients in preventing stillbirths (OR = 0.82, 95% CI: 0.38–1.77; and OR = 6.69, 95% CI: 0.13–338.79; for twin and triplet pregnancies, respectively) [LOE: 1++].

Table 14 Impact of home versus hospital-based bed rest and monitoring in high-risk pregnancy on stillbirth and perinatal mortality

Another Cochrane review [130] evaluated the impact of different degrees of bed rest compared with routine activity, as well as the effects of hospital-based versus home-based bed rest, in hypertensive pregnant women both with and without proteinuria (4 RCTs, N = 449 women) (Additional file 18). Three studies were of good quality, but only 1 reported stillbirth as outcome, reporting no impact of hospital-based bed rest versus routine activity at home on stillbirth (RR = 4.91, 95% CI: 0.24–101.10). Only 1 RCT (N = 218 women) of the 2 studies comparing hospital-based bed rest with routine activity at home in cases of non-proteinuric hypertension reported stillbirth and neonatal death as a combined measure. There was no evidence of impact of hospital-based bed rest on this composite measure (RR = 1.96, 95% CI: 0.18–21.34), though they did report a reduced risk of severe hypertension (RR = 0.58, 95% CI: 0.38–0.89) and a borderline reduction in risk of pre-term birth (RR = 0.53, 95% CI: 0.29–0.99) compared to normal domiciliary activity [LOE: 1++]

In The Netherlands, an RCT [131] compared domiciliary care to hospital-based care in high-risk pregnant women (N = 150). There was 1 perinatal death in each group (1/77 versus 1/74 in home- versus hospital-based groups, respectively), and the only stillbirth occurred in the domicilary care group (1/77 versus 0/74 in home- versus hospital-based groups, respectively); the sample was too small to assess statistical significance [LOE: 1-]. A large RCT from China [132] (N = 13,006 women) compared a protocol of self-monitoring at home to a control group managed at hospitals. Both perinatal mortality and fetal deaths were lower among the self-monitoring group (perinatal mortality: 6.30% versus 10.92% in self-monitoring versus control groups, respectively, P < 0.05; fetal deaths: 3.23% versus 6.34%, respectively, P < 0.05).

Conclusion

The limited evidence available (Grade D evidence) suggests that home-based care for certain subsets of women with uncomplicated high-risk pregnancy has no apparent disadvantage compared with hospital-based bed rest and monitoring in terms of impact on stillbirths and perinatal mortality. The number of studies on this subject is small, however, and limited to the conditions of multiple gestation and hypertensive disorders of pregnancy, exclusively in high-resource settings. As one RCT above indicated, bed rest in hospital for non-proteinuric hypertension may be superior to home-based care [133], but insufficient evidence exists to recommend hospitalization in this case, as the study was underpowered. The Cochrane review found that in multiple pregnancy, bed rest (in hospital) appears to confer little advantage over no modification of physical activity; bed rest had no impact on rates of perinatal mortality, stillbirth, or pre-term birth, but may improve fetal growth [127]. The potential cost savings and increased convenience to women of home-based bed rest and monitoring indicates that further large studies of the efficacy of bed rest as an intervention as well as monitoring at home versus in hospital are needed, particularly studies that include economic analyses of costs to mothers and hospitals.

In-hospital fetal surveillance units

Background

A fetal surveillance unit provides a wide range of maternal and fetal diagnostic tests, often on an outpatient basis, of particular benefit in identifying and monitoring high-risk pregnancies. Antenatal fetal surveillance protocols, which may include multiple surveillance methods at a specified frequency, have the potential to impact perinatal mortality, neonatal morbidity, birth weight in cases of fetal growth problems, rates of prematurity, and length of hospital admission. Assessment of fetal condition can usually be performed on an outpatient basis, with admission reserved for delivery, which is usually less disruptive to the pregnant woman's family [134]. Specially designated antenatal surveillance units that offer predominantly outpatient services also offer operating cost savings compared with standard hospital admission.

Literature-based evidence

Our literature search identified 1 Cochrane review, 1 Cochrane protocol and 2 other intervention studies (Table 15). A Cochrane review [135] evaluated the use of antenatal outpatient day care units as an alternative to inpatient care for women with complicated pregnancy (1 RCT, N = 54 women) [136] (Additional file 19). Day care unit assessment for non-proteinuric hypertension reduced subsequent inpatient stay (difference in mean stay: 4.0 days; 95% CI: 2.1–5.9 days). The rate of induction of labour was much higher in the hospital-based inpatient care group compared to the day care unit group (OR = 4.9, 95% CI: 1.6–13.8). There were no perinatal deaths in either group [LOE: 1+]. The Cochrane protocol, for a review currently in progress, proposes to assess the impact of different specified regimens of fetal surveillance for impaired fetal growth on maternal and perinatal outcomes and length of hospital admission [137]. The 2 intervention studies adopted different approaches. Soothill et al [134] conducted a before-after intervention study comparing the number and length of antenatal admissions in the 5 months after the opening of a perinatal care unit providing largely outpatient-based services to records from the 6 months prior to the opening. They found no significant change in stillbirth rate (6/1294 versus 8/1372 after versus before, respectively; rate difference (RD) = 0.0012, 95% CI: -0.0043–0.0067) [LOE: 2+], suggesting that fetal surveillance on an outpatient basis was equally effective as hospital admission in managing high-risk pregnancy. Menzies et al. [138] performed a similar study of all women admitted with pre-eclampsia to a tertiary-level perinatal unit before and after introducing standardised assessment and surveillance, and reported that perinatal outcomes did not change [LOE: 2-].

Table 15 Impact of a fetal surveillance unit on stillbirth and perinatal outcomes
Conclusion

If patients could be consistently monitored on an outpatient basis, obstetricians would be more willing to admit patients only for delivery, and to perform more fetal assessments and maternal tests as outpatient services. Outpatient fetal surveillance offers benefits in terms of cost and convenience, and could improve health facility organisation, and improved record-keeping would streamline obstetric and perinatal audit, data quality for research, and teaching opportunities [135]. However, the evidence base for the benefits of outpatient surveillance of high-risk pregnancies is relatively limited, as the single Cochrane review on the subject included 1 small RCT that reported no perinatal deaths (Grade C evidence). The reduced rates of induction of labour are of interest and require further trials reporting labour induction rates with sufficient power to detect differences in subsequent perinatal outcomes. At this time, even in high-resource settings, in-hospital fetal surveillance units cannot be recommended as an intervention to prevent stillbirths.

Monitoring in labour

Use of the partograph

Background

A partograph, alternatively called a partogram, is a simple pre-printed paper form on which midwives and obstetricians record labour observations. The tool provides a continuous pictorial overview of the progress of labour, while monitoring maternal and fetal well-being. The partograph distinguishes between the latent and active phases of labour. The active labour section has 2 straight lines called the alert and action lines. The alert line reflects a modification of the mean rate of cervical dilatation of the slowest 10% of primigravid women in the active phase of labour (1 cm per hour). Slower progress than this crosses the alert line on the partograph, which may prompt initiation of the process of transfer to a facility with emergency obstetric capacity in preparation for intervention for prolonged labour. Depending on the partograph version, the 'action line' is 2 to 4 hours to the right of the alert line. Labour crossing this line suggests primary inefficient uterine activity and prompts immediate appropriate management of slow progress of labour, usually via amniotomy, oxytocin infusion, or both.

Some evidence suggests that midwives and physicians find the partograph practical in terms of ease of use, time resourcefulness, continuity of care and educational assistance [139], which may contribute to positive maternal and fetal outcomes. Partographs are also inexpensive and relatively simple to use, making their use attractive in low-resource settings where other intrapartum monitoring technologies are unavailable or prohibitively expensive. In higher-resource settings, the partograph can be implemented alongside other fetal surveillance tests such as cardiotocography to provide more information for decision-making. However, some practitioners view the partograph as inappropriately restrictive and formulaic, prompting intervention prematurely [139], factors which could impact both clinical and maternal psychological outcomes. Various versions of the partograph are marked by different slope and position of the action line, which is likely to impact labour augmentation interventions, Caesarean section rates, and maternal satisfaction.

Literature-based evidence

We identified 1 Cochrane review including 5 RCTs and quasi-RCTs (N = 6963 women), and 3 intervention/observational studies (Table 16). The Cochrane review [140] compared the impact of use of the partograph in comparison with no partograph, as well as different versions of the partograph, for monitoring the progress of spontaneous labour at term (Additional file 20). None of the included studies reported intrapartum stillbirth rates, though several reported neonatal outcomes. The randomised controlled trials (RCTs) in the review that compared partograph use to no partograph use (2 trials; N = 1590 women)[141, 142] showed no impact of partograph use on Caesarean section rate (risk ratio (RR) = 0.64, 95% confidence interval (CI): 0.24–1.70), instrumental vaginal delivery (RR = 1.00, 95% CI: 0.85–1.17) or Apgar score < 7 at 5 minutes (RR = 0.77, 95% CI: 0.29–2.06).

Table 16 Impact of use of the partograph in stillbirth and perinatal outcomes

The Cochrane review [140] also compared the impact of different versions of the partograph with different action line placement on labour outcomes. Two RCTs, both conducted in high-resource settings, compared different partograph versions with the action line either 2 hours or 4 hours after the alert line (N = 3601 women) [143, 144], and found no difference in Caesarean section rates between labours monitored with the 2 different partographs (RR = 1.06, 95% CI: 0.85–1.32 [NS]). Women in the 2-hour action line group were significantly more likely to receive oxytocin augmentation (RR = 1.14, 95% CI: 1.05–1.22). One RCT, also in a high-resource setting, compared a 2-hour versus a 3-hour action line (N = 617 women)[143]. There was no difference in Caesarean section (RR = 0.78, 95% CI: 0.51–1.18). Maternal satisfaction with care was higher in the 2-hour action line group than the 3-hour action line group (RR = 0.49, 95% CI: 0.27–0.90). There was no difference in neonatal outcomes. One RCT in a high-resource setting compared the impact of partographs with a 3-hour versus a 4-hour action line (N = 613) [143]. The Caesarean section rate was significantly lower in the 4-hour action line group (RR = 1.70, 95% CI: 1.07–2.70) but there was no difference in neonatal outcomes. One RCT in a low-resource setting compared a partograph with no action line (alert line only) to a partograph with an action line (N = 694 women) [145]. The Caesarean section rate was lower in the group with no action line (RR = 0.68, 95% CI: 0.50–0.93), but there was no difference in neonatal outcomes.

The review also pooled the results from 3 RCTs to compare shorter (2-hour action line or alert line only) versus longer time-to-intervention (4-hour action line or alert plus action lines) and found no differences between the groups for Caesarean section rate, Apgar score or instrumental delivery, but early intervention in the low-resource setting reduced the Caesarean section rate.

A large multicentre study [146] compared the impact of partograph use in multiple hospitals in Southeast Asia (N = 35,484 women). The reported stillbirth rate was 0.3% in the group for which the partograph was used, versus 0.5% in the control group; this small difference was not assessed for statistical significance because partograph use was introduced in stages. A sub-study using the same WHO dataset of breech birth management using the partograph [147] found a non-significant decrease in intrapartum stillbirth after the introduction of the partograph compared with before (1.1% versus 1.9% after versus before, respectively).

In Indonesia, Fahdhy et al [148] compared the use of midwives trained to employ the partograph versus standard midwifery care without the partograph. Seventy-one of 304 labours plotted on the partograph progressed beyond the alert line; the study reported significant decreases in obstructed labour, oxytocin use, and Apgar score less than 7 at 1 minute, but there were only non-significant reductions in fetal death and early neonatal death [adjusted OR for fetal death = 0.62, 95% CI: 0.17–2.19 (NS); adjusted OR for neonatal death = 0.70, 95% CI: 0.16–3.11(NS)].

Conclusion

Overall, there were no significant differences in maternal or perinatal outcomes with the use of partograph versus no partograph, and no evidence that any particular version of the partograph is better than another in preventing perinatal mortality. Partographs may be comparatively more effective in low-resource settings, as the studies from Africa and Mexico in the Lavender review [140], as well as data from Southeast Asia [146] that showed reduced Caesarean section rates with use of the partograph and early intervention for slow progress of labour. The data from Southeast Asia and Indonesia also showed trends toward improved birth outcomes [146]. Overall, the evidence for partograph use is Grade C. Given the limitations of the studies included and the potential impact of organisational issues, e.g. guidelines on partograph use, a large cluster-RCT in low-resource settings is recommended to compare partograph versus no partograph use, specifically including stillbirths as a reported outcome.

Intrapartum cardiotocography with and without pulse oximetry

Background

Methods to assess fetal heart rate and levels of oxygenation of fetal blood are monitoring strategies intended to identify early signs of fetal compromise as a result of oxygen shortage, or fetal hypoxia [2]. Severe and prolonged hypoxia is associated with stillbirth, early neonatal death, and long-term physical or mental disability, including cerebral palsy, if the baby survives. Fetal heart rate patterns are classified as either reassuring, nonreassuring or abnormal, considering heart rate baseline, variability, and decelerations. While nonreassuring tests may become reassuring with simple change in maternal position, abnormal fetal heart rate alterations or low blood oxygen levels are a frequent indication for Caesarean or instrumental delivery [149].

In many hospitals in high-income countries including the US and Canada, cardiotocography is widely used to monitor fetal heart rate in labour, though intermittent auscultation (periodic listening to the fetal heart rate using a stethoscope or handheld Doppler device) is occasionally performed. In addition to external cardiotocography, which can be employed continuously or intermittently during labour, internal cardiotocography can be performed by attaching a sensor to the fetal presenting part, usually its head. This can be done only if the membranes are ruptured, as an electrode must be embedded in the baby's scalp. Intermittent auscultation via stethoscope or handheld Doppler is more common than electronic fetal monitoring methods in low-resource settings where fetal heart rate monitoring is available.

Currently, cardiotocography is recommended in high-risk pregnancy and labours induced or augmented with oxytocin [150]. Because of the poor ability of cardiotocography alone to detect true fetal distress, the practice of pulse oximetry is thought to provide additional helpful information to corroborate cardiotocographic traces. Pulse oximetry is intended as a follow-up procedure in the presence of a nonassuring cardiotocographic test, and is intended to improve the accuracy of the assessment of fetal well-being in the intrapartum period [151]. In this procedure, a sensor is attached via a clip to the fetus, generally on the scalp, cheek, temple, or back; oxygenation values exceeding 30% are considered reassuring even when a cardiographic trace is nonreassuring [152]. While non-reassuring tests may become reassuring with simple change in maternal position, abnormal fetal heart rate alterations are a frequent indication for Caesarean or instrumental delivery [149].

There is some danger that improper interpretation of cardiotocographic tracings can lead to inappropriate intervention, or false reassurance that delays necessary intervention. There is a need for sensitive and specific methods of using cardiotocography, potentially in conjunction with pulse oximetry, to improve detection of fetal compromise due to hypoxia. Improved detection of hypoxia, primarily by expediting delivery, could improve outcomes and prevent stillbirth in these instances.

Literature-based evidence

The literature review identified two Cochrane reviews on intrapartum cardiotocography, one Cochrane review examining pulse oximetry in conjunction with cardiotocography, and two other observational/interventional studies (Table 17). In a large Cochrane review (12 trials, N>37,000 women), Alfirevic and Devane [2] evaluated RCTs and quasi-RCTs comparing continuous cardiotocography in labour (with and without fetal blood sampling) with no fetal monitoring, intermittent auscultation, or intermittent cardiotocography (Additional file 21). Compared to intermittent auscultation, continuous cardiotocography showed no significant difference in overall PMR (11 trials, N = 33,513 women, RR = 0.85, 95% CI: 0.59–1.23), but did significantly reduce the risk of neonatal seizures (RR = 0.50, 95% CI: 0.31–0.80, 9 trials, N = 32,386) although no significant difference was detected in cerebral palsy (RR = 1.74, 95% CI: 0.97–3.11, 2 trials, N = 13,252). Continuous cardiotocography was associated with an increased risk of Caesarean delivery (RR = 1.66, 95% CI: 1.30–2.13, 10 trials, N = 18,761 women) and instrumental vaginal birth (RR = 1.16, 95% CI: 1.01–1.32, 9 trials, N = 18,151 women). Results of subgroup analysis were consistent with overall results presented above, and the addition of fetal blood sampling appeared to have no effect on outcomes [LOE: 1+]. A new Cochrane review assessing cardiotocography versus intermittent auscultation of fetal heart for assessment of fetal well-being is in progress [153].

Table 17 Impact of intrapartum cardiotocography with or without pulse oximetry on stillbirth and perinatal outcomes

Another Cochrane review [154] (4 RCTs, N = 9829 women) compared fetal electrocardiogram ST waveform analysis with alternative methods of fetal monitoring during labour, including continuous cardiotocography (Additional file 22). In comparison to continuous cardiotocography alone, the use of adjunctive electrocardiogram analysis reduced the risk of neonatal acidosis at birth (3 trials, N = 8872 women; RR = 0.64, 95% CI: 0.41–1.00, N = 8108 babies) and neonatal encephalopathy (3 RCTs, RR = 0.33, 95% CI: 0.11–0.95). Procedurally, adjunctive electrocardiogram evaluating the ST segment was associated with fewer fetal scalp samples during labour (3 RCTs, RR = 0.76, 95% CI: 0.67–0.86) and fewer instrumental vaginal deliveries (3 RCTs, RR = 0.87, 95% CI: 0.78–0.96), but had no impact on Caesarean section rates or Apgar score < 7 at 5 minutes. Use of another electrocardiogram method, time-interval analysis, showed no benefit other than a trend towards fewer operative deliveries (1 RCT, RR = 0.87, 95% CI: 0.76–1.01); there was no significant increased risk of perinatal death in the electrocardiogram plus cardiotocography group versus the group with cardiotocography alone (RR = 2.29, 95% CI: 0.59–8.83) [LOE: 1++].

A third Cochrane review [149] assessed RCTs that comparied maternal and fetal outcomes after fetal pulse oximetry was used in labour (with or without concurrent use of cardiotocography or auscultation), compared with cardiotocography alone (Additional file 23). Adjunctive fetal pulse oximetry with cardiotocography was associated with significantly decreased rates of Caesarean section for nonreassuring fetal status compared to cardiotocography alone in groups without fetal blood sampling prior to study entry (RR = 0.68, 95% CI: 0.47–0.99), and in groups with fetal blood sampling prior to study entry (RR = 0.03, 95% CI: 0.00–0.44). Based on 2 trials reporting outcomes, there was no impact of adding fetal pulse oximetry to cardiotocography on fetal/neonatal death (RR = 0.93, 95% CI: 0.20–4.44) [LOE: 1++].

Conclusion

Although there are several studies of fetal pulse oximetry and intrapartum cardiotocography, few reported stillbirth or perinatal mortality as outcomes. The available results show no statistically significant impact on stillbirths or perinatal mortality, whether cardiotocography is used alone or in conjunction with fetal pulse oximetry in labour. Continuous cardiotocography appears associated with increased rates of operative delivery and lower rates of neonatal seizures compared to no or intermittent cardiotocography, but has no demonstrated impact on rates of perinatal mortality, acidosis, dystocia, or long-term physical or developmental outcomes. There is currently no evidence of benefit from randomised or quasi-randomised studies for intrapartum cardiotocography alone or in conjunction with electrocardiogram or fetal pulse oximetry in preventing stillbirth.

One drawback of intrapartum cardiotocography is that its poor predictive value of true fetal distress and hypoxia is not sufficiently enhanced by any adjunctive technologies at this time. Pulse oximetry appears safe, though long-term developmental studies have not been performed, but it does not have any clear impact on stillbirths or perinatal mortality [149]. Adjunctive electrocardiogram possibly reduces neonatal encephalopathy, academia, and instrumental delivery, but these findings need additional research to verify. Minimally invasive technologies and tests are needed in addition to intrapartum cardiotocography to more accurately identify intrapartum hypoxia and dystocia.

There are robust studies and Cochrane reviews on fetal pulse oximetry and intrapartum cardiotocography (Grade B evidence). The non-significant impact of cardiotocography with or without fetal pulse oximetry on stillbirth/perinatal mortality in these studies suggests no evidence of benefit. In high-income countries, documented stillbirth rates, particularly stillbirths associated with intrauterine asphyxia, have declined following increasing prevalence of cardiotocographic fetal monitoring with Caesarean section for fetal distress [155–157], though this association may be confounded. Electronic fetal monitoring (with access to operative delivery) may be an important tool in the arsenal of strategies to prevent stillbirth, though this is unproven. More precise tests for fetal distress and indications for Caesarean section are needed.

Summary

Although a reasonable number of Cochrane reviews and RCTs were available which assessed the impact of one or more implementation strategies for many screening and monitoring interventions, none of the interventions we reviewed demonstrated convincing evidence of impact on stillbirths or perinatal mortality. A number of studies that did report statistically significant impact on stillbirth or perinatal mortality, or which suggested large magnitude differences between intervention and control/comparison groups, lacked sufficient rigor to justify recommending the routine use of the interventions evaluated.

The evidence for all interventions reviewed in this paper is summarised in Table 18. Of the range of monitoring interventions evaluated, fetal movement counting and Doppler monitoring were promising for further evaluation in high-risk pregnancies in low-resource settings. Low amniotic fluid measurements were strongly predictive of stillbirth, but interventions to restore adequate amniotic fluid volume or to deliver the baby based on identification of oligohydramnios have not been systematically tested to conclude whether amniotic fluid assessment is a useful diagnostic tool that leads to actions which prevent stillbirth.

Table 18 Collective grading of evidence for impact of monitoring interventions in pregnancy on stillbirth and related perinatal outcomes

Research gaps

Despite the existence of many tools, devices, and techniques for monitoring pregnancy for complications, there is a dearth of rigorous evidence that any screening and monitoring intervention has a direct impact on stillbirth rates in unselected and low-risk populations. This stems from several common shortcomings in the design and interpretation of studies investigating the use of screening and monitoring techniques. First, the small size and insufficient rigor of many screening and monitoring studies to date renders them underpowered to detect significant differences in perinatal mortality subsequent to their implementation. Many studies assessing the impact of the interventions covered in this review did not report stillbirths or perinatal mortality at all. For virtually all the interventions included in this review (with the exception of x-ray pelvimetry), there is a need for RCTs sufficiently powered to detect statistically significant impact on stillbirth or perinatal mortality, if such differences exist. Second, for screening and monitoring interventions to reduce stillbirth incidence, they must effectively identify women at higher risk of stillbirth in time for an appropriate and effective intervention to be provided. Most studies we reviewed limited their analysis to the first step of successful screening or monitoring: detection of women at increased risk of stillbirth or perinatal death. A number of studies showed that positive test results corresponded fairly well with increased risk of adverse pregnancy outcome. However, a trial of an otherwise effective screening method will show no impact on stillbirths if the subsequent intervention fails to prevent stillbirth, either because intervention is ineffective or provided too late. In most of the studies we reviewed, few women who screened positive were treated according to an established protocol. This flaw precludes assessment of whether the lack of impact of any given screening technique is attributable to a failed screening method or a failed intervention. This fact highlights the need for time-to-decision and time-to-intervention studies, as well as analyses that consider which interventions are employed, and protocols for employing them, subsequent to adverse findings of screening and monitoring studies. The quality, appropriateness, and timeliness of the intervention care provided must also be considered along with the effectiveness of screening or monitoring in detecting true complications.

In addition to these tests of diagnostic accuracy and intervention effectiveness, other types of studies are also needed, including innovative pilot studies, safety studies, and effectiveness trials, to bolster the weak evidence base for screening and monitoring interventions during labour (Table 19). In high-income countries, there is a particular need for better understanding of placental pathophysiology, as up to half of unexplained stillbirths show signs of growth restriction, much of which is attributed to placental insufficiency [158]. Placental dysfunction is often observed in other major known causes of stillbirth including pre-eclampsia and abruption, suggesting the need for accurate placental function or placental biomarker screening tests, especially those appropriate for use in unselected populations. One such test in early pregnancy which measures pregnancy associated plasma protein-A has been associated with a 40–50-fold increase in risk of stillbirth due to placental dysfunction in a selected population, but it is unclear what interventions could prevent stillbirth among women with such positive test results [159]. Appropriate management of pregnancies complicated by placental dysfunction and/or fetal growth restriction requires further research, particularly when detected too early in pregnancy to consider early delivery.

Table 19 Research gaps

Additional questions surround which screening and monitoring interventions could be most effective in low-/middle-income country settings where 98% or more of the global burden of stillbirths occurs [160]. Screening and monitoring are often technology-dependent, as illustrated by the cardiotocographic machine required for the BPP, CST, and NST; and the use of video ultrasound machines for amniotic fluid assessment. This makes some of these interventions impractical or unaffordable in low-resource or remote settings at the present time. However, certain technologies, such as handheld Doppler ultrasound and video ultrasound scanning machines, are increasingly available in low-resource settings; there is a need for studies to define the most cost-effective ways of using these and other available technologies to identify high-risk pregnancies. Additionally, other techniques, such as fetal movement monitoring and the partograph, require little investment other than training of midwives or mothers, and may be appropriate for use in high-risk pregnancies, if these pregnancies can be identified and if the use of these techniques result in improved outcomes, which has not yet been conclusively demonstrated. Additionally, there is some potentially promising evidence that fetal surveillance typically provided on an inpatient basis, often with bed rest, for high-risk pregnancies can be offered on an outpatient basis with bed rest or reduced activity at home without deleterious impact on pregnancy outcomes; this evidence requires confirmatory effectiveness trials in low-resource settings before programmatic adoption of this approach could be recommended.

Practicality, logistical feasibility, and cost-effectiveness are chief concerns in many low-resource areas. Where ANC services are available and widely utilised, the prospects for identifying and monitoring high-risk pregnancy improve. Along with interventions that improve detection of risk factors and complications, improved management and referral of women with complications are critical to manage obstetric risk in low-/middle-income countries. Unfortunately, in areas where ANC attendance is poor, few of these screening and monitoring techniques are likely to be implementable.

Implications for programmes and clinical practice

A few monitoring approaches showed promise for use in high-risk pregnancies, including fetal movement monitoring and umbilical Doppler velocimetry. Before recommending these interventions for widespread use, further large RCTs of sufficient rigour to detect differences in stillbirth and perinatal outcomes are needed to determine the utility and effectiveness of these monitoring approaches and interventions used after positive tests.

This review identified several interventions – for example, amniotic fluid measurement for signs of oligohydramnios, especially as pregnancy approaches or exceeds term; routine ultrasound scanning, and intrapartum cardiotocography – that are in widespread use in high-resource settings, but for which rigorous evidence is lacking. For these interventions, their continued use is reasonable even though the evidence base for impact on stillbirths is lacking. Intrapartum cardiotocography in particular has been shown in RCTs to elevate the risk of operative delivery. Prevailing wisdom credits cardiotocography and available Caesarean section with the diminution of stillbirth rates in high-income countries in recent decades; however, the role of cardiotocography in reducing stillbirth should be confirmed with more rigorous evidence. Efforts to achieve glycaemic control in cases of maternal diabetes mellitus are also encouraged, despite the lack of strong evidence showing an impact of such interventions on stillbirth, on the grounds that women with good glycaemic control experience fewer complications and negative outcomes of pregnancy.

Particularly in pregnancies deemed high-risk based on screening test results, clinical progression of pregnancy, or reproductive history, multiple antepartum testing modalities can minimise deficiencies in sensitivity and predictive value when used in combination to assess fetal well-being and abnormalities. The BPP reflects one standardised strategy by which tests of fetal well-being have been packaged to permit a more comprehensive assessment of fetal well-being. In cases where one test raises the possibility that a pregnancy is high-risk, multiple tests of fetal well-being should be considered if time allows, along with the patient's overall clinical history, to determine the appropriateness of intervention. Multiple tests are recommended in many protocols for identifying and making clinical decisions about management of pregnancies with suspected fetal growth restriction [161]. In these cases the collective results of a battery of tests including all the components of the BPP and Doppler velocimetry, as well as ultrasound biometry, can be informative in decision-making to maximise gestational age and inform the strategic timing of corticosteroid administration and early delivery via induction or Caesarean section. However, conflicting test results – a recent study showed only 44.5% concordance between BPP and Doppler assessments of compromise in growth-restricted fetuses – can complicate interpretation [162].

Recommendations for clinical decision-making protocols and introduction of interventions in low-/middle-income countries are more difficult. Resource constraints preclude the implementation of many of the interventions reviewed in this paper. The interventions requiring the lowest investment in resources and training – fetal movement monitoring and the partograph – show some evidence of benefit in high-risk pregnancies, but more studies are needed. Where safe Caesarean section is available, ensuring that intermittent or continuous intrapartum fetal heart rate monitoring is performed may improve targeting of Caesarean section while improving birth outcomes.

Screening and monitoring interventions cannot be effective without responsive, quality care and careful clinical management, particularly for high-risk pregnancies. Health systems quality improvement activities, including boosting provider skill in interpreting test results and determining appropriate intervention, timely response including swift referral, and evaluative strategies to document outcomes after intervention are essential complementary activities to ensure that an effective screening or monitoring technique translates to measurable improvements in perinatal mortality outcomes.

Conclusion

Screening pregnancies to identify risk factors, complications, or indications of fetal distress and providing appropriate surveillance for identified risk factors theoretically encourages appropriate use of interventions, including induction of labour, Caesarean section, and pharmacological treatment, to prevent fetal loss and adverse maternal or neonatal outcomes. Screening and monitoring are futile, however, in the absence of effective interventions to act promptly and appropriately to manage identified risk factors and complications. The weak evidence in this review for impact of screening and monitoring interventions on stillbirth incidence is due at least in part to limitations in study designs that result in uninterpretable data. Screening tests may be ineffective, inappropriate, or occur too late to prevent adverse outcomes, but more problematically, most studies did not report the impact of intervention (particularly standardised intervention) following positive screening test results. Effective interventions exist to prevent stillbirth associated with many maternal infections or conditions (e.g., syphilis, malaria, pre-eclampsia) and placental dysfunction (e.g., oligohydramnios, placental insufficiency, abruption). Because screening and monitoring techniques during pregnancy also pose the risk of inappropriate or unnecessary use of drugs, induction of labour, iatrogenic preterm birth, or Caesarean section, it is practically, ethically, and economically important to validate the sensitivity, specificity, and positive predictive value of available screening and monitoring techniques to protect women and their babies from iatrogenic harm; and to ensure the wise use of scarce medical resources in low- and middle-income settings.

Abbreviations

AFI:

amniotic fluid index

ANC:

antenatal care

BPP:

biophysical profile

CI:

confidence interval

CST:

contraction stress test

CTG:

cardiotocography

ECG:

electrocardiogram

FHR:

fetal heart rate

HR:

hazard ratio

IU:

international units

LOE:

level of evidence

NS:

non-significant

NST:

non-stress test

OR:

odds ratio

PMR:

perinatal mortality rate

PPV:

positive predictive value

PROM:

premature rupture of membranes

PPROM:

pre-term premature rupture of membranes

RCT:

randomised clinical/controlled trial

RD:

risk difference

RI:

resistance index

RR:

relative risk/risk ratio

SB:

stillbirth

SBR:

stillbirth rate

SD:

standard deviation

SGA:

small for gestational age

TBA:

traditional birth attendant

UK:

United Kingdom

USA:

United States of America

WHO:

World Health Organisation

WMD:

weighted mean difference.

References

  1. Lalor JG, Fawole B, Alfirevic Z, Devane D: Biophysical profile for fetal assessment in high risk pregnancies. Cochrane Database Syst Rev. 2008, CD000038-1

  2. Alfirevic Z, Devane D, Gyte GM: Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev. 2006, 3: CD006066-

    PubMed  Google Scholar 

  3. Katz M, Meizner I, Insler V: Fetal Well-being: Physiological Basis and Methods of Clinical Assessment. 1990, CRC Press

    Google Scholar 

  4. Lawn JE, Yakoob MY, Haws RA, Soomro T, Darmstadt GL, Bhutta ZA: 3.2 million stillbirths: epidemiology and overview of the evidence review. BMC Pregnancy and Childbirth. 2009, 9 (Suppl 1): S2-10.1186/1471-2393-9-S1-S2.

    PubMed Central  PubMed  Google Scholar 

  5. Coopland AT, Peddle LJ, Baskett TF, Rollwagen R, Simpson A, Parker E: A simplified antepartum high-risk pregnancy scoring form: statistical analysis of 5459 cases. Can Med Assoc J. 1977, 116 (9): 999-1001.

    PubMed Central  CAS  PubMed  Google Scholar 

  6. Hobel CJ, Hyvarinen MA, Okada DM, Oh W: Prenatal and intrapartum high-risk screening. I. Prediction of the high-risk neonate. Am J Obstet Gynecol. 1973, 117 (1): 1-9.

    CAS  PubMed  Google Scholar 

  7. Lilford RJ, Chard T: Problems and pitfalls of risk assessment in antenatal care. Br J Obstet Gynaecol. 1983, 90 (6): 507-510.

    CAS  PubMed  Google Scholar 

  8. Pattison NS, Sadler L, Mullins P: Obstetric risk factors: can they predict fetal mortality and morbidity?. N Z Med J. 1990, 103 (891): 257-259.

    CAS  PubMed  Google Scholar 

  9. Knox AJ, Sadler L, Pattison NS, Mantell CD, Mullins P: An obstetric scoring system: its development and application in obstetric management. Obstet Gynecol. 1993, 81 (2): 195-199.

    CAS  PubMed  Google Scholar 

  10. Chard T, Learmont J, Carroll S, Hudson C, Lloyd DS, Sloan D: Evaluation of a fetal risk-scoring system. Am J Perinatol. 1992, 9 (5–6): 388-393. 10.1055/s-2007-999272.

    CAS  PubMed  Google Scholar 

  11. Morrison I, Olsen J: Perinatal mortality and antepartum risk scoring. Obstet Gynecol. 1979, 53 (3): 362-366.

    CAS  PubMed  Google Scholar 

  12. Majoko F, Nystrom L, Munjanja S, Lindmark G: Usefulness of risk scoring at booking for antenatal care in predicting adverse pregnancy outcome in a rural African setting. J Obstet Gynaecol. 2002, 22 (6): 604-609. 10.1080/0144361021000020358.

    CAS  PubMed  Google Scholar 

  13. Talsania NJ, Lala MK: Scoring of high risk pregnant women and related outcome. Indian J Matern Child Health. 1991, 2 (3): 92-94.

    CAS  PubMed  Google Scholar 

  14. Talsania NJ, Lala MK: Evaluation of antenatal risk scoring in a preterm birth prevention and perinatal loss. Indian J Matern Child Health. 1994, 5 (1): 5-9.

    CAS  PubMed  Google Scholar 

  15. LeFevre M, Williamson HA, Hector M: Obstetric risk assessment in rural practice. J Fam Pract. 1989, 28 (6): 691-695. discussion 695–696

    CAS  PubMed  Google Scholar 

  16. Humphrey MD: The beneficial use of risk scoring in a remote and high-risk pregnant population. J Perinat Med. 1990, 18 (1): 23-29.

    Google Scholar 

  17. de Caunes F, Alexander GR, Berchel C, Guengant JP, Papiernik E: Anamnestic pregnancy risk assessment. Int J Gynaecol Obstet. 1990, 33 (3): 221-227. 10.1016/0020-7292(90)90005-6.

    CAS  PubMed  Google Scholar 

  18. Abraham S, Joshi S, Kumar V, Patwary A, Pratinidhi A, Saxena VB, Maitra K, Singh KK, Saxena NC, Saxena BN: Indian experience of home based mothers' card: ICMR task force study. Indian J Pediatr. 1991, 58: 795-804. 10.1007/BF02825437.

    CAS  PubMed  Google Scholar 

  19. Wall EM: Assessing obstetric risk. A review of obstetric risk-scoring systems. J Fam Pract. 1988, 27 (2): 153-163.

    CAS  PubMed  Google Scholar 

  20. Velazquez MD, Rayburn WF: Antenatal evaluation of the fetus using fetal movement monitoring. Clin Obstet Gynecol. 2002, 45 (4): 993-1004. 10.1097/00003081-200212000-00006.

    PubMed  Google Scholar 

  21. Boehm FH, Gabbe SG: Putting it all together. Clin Obstet Gynecol. 2002, 45 (4): 1063-1068. 10.1097/00003081-200212000-00012.

    PubMed  Google Scholar 

  22. Mangesi L, Hofmeyr GJ: Fetal movement counting for assessment of fetal wellbeing. Cochrane Database of Systematic Reviews. 2007, 1: CD004909-

    PubMed  Google Scholar 

  23. Lema VM, Rogo KO, Mwalali PN: Fetal movements: value in monitoring high-risk pregnancies. East Afr Med J. 1988, 65: 785-792.

    CAS  PubMed  Google Scholar 

  24. De Muylder X: The kick chart in high-risk pregnancies: a two-year experience in Zimbabwe. Int J Gynaecol Obstet. 1988, 27 (3): 353-357. 10.1016/0020-7292(88)90112-9.

    CAS  PubMed  Google Scholar 

  25. Sinha D, Sharma A, Nallaswamy V, Jayagopal N, Bhatti N: Obstetric outcome in women complaining of reduced fetal movements. J Obstet Gynaecol. 2007, 27 (1): 41-43. 10.1080/01443610601016909.

    CAS  PubMed  Google Scholar 

  26. Romero Gutierrez G, Sanchez Cortes R, Soto Pompa V, Rodriguez Flores P: [Perinatal morbidity and mortality associated with fetal hypomotility]. Ginecol Obstet Mex. 1994, 62: 222-225.

    CAS  PubMed  Google Scholar 

  27. Moore TR, Piacquadio K: A prospective evaluation of fetal movement screening to reduce the incidence of antepartum fetal death. Am J Obstet Gynecol. 1989, 160 (5 Pt 1): 1075-1080.

    CAS  PubMed  Google Scholar 

  28. Grant A, Elbourne D, Valentin L, Alexander S: Routine formal fetal movement counting and risks of antepartum late deaths in nomally formed singletons. Lancet. 1989, 2: 345-347. 10.1016/S0140-6736(89)90535-7.

    CAS  PubMed  Google Scholar 

  29. National Institute for Health and Clinical Excellence: CG62: Antenatal care – Routine care for the healthy pregnant woman, full guideline. 2008, (accessed 31 Jan 2009), [http://www.nice.org.uk/Guidance/CG62/NiceGuidance/pdf/English]

    Google Scholar 

  30. Del Mar C, O'Connor V: Should we stop telling well pregnant women to monitor fetal movements? How to use and interpret guidelines. Br J Gen Pract. 2004, 54 (508): 810-

    PubMed Central  PubMed  Google Scholar 

  31. Neilson J: Ultrasound for fetal assessment in early pregnancy. Cochrane Database of Systematic Reviews. 1998, CD000182-4

  32. Mahran M, Omran M: The impact of diagnostic ultrasound on the prediction of intrauterine growth retardation in developing countries. Int J Gynaecol Obstet. 1988, 26 (3): 375-378. 10.1016/0020-7292(88)90332-3.

    CAS  PubMed  Google Scholar 

  33. Whitworth M, Bricker L, Neilson JP: Ultrasound for fetalassessment in early pregnancy (Protocol). Cochrane Database of Systematic Reviews. 2008, 1 (2): CD007058-

    Google Scholar 

  34. Bricker L, Neilson JP, Dowswell T: Routine ultrasound in late pregnancy (after 24 weeks' gestation). Cochrane Database Syst Rev. 2008, CD001451-4

  35. Duff GB: A randomized controlled trial in a hospital population of ultrasound measurement screening for the small for dates baby. Aust N Z J Obstet Gynaecol. 1993, 33 (4): 374-378. 10.1111/j.1479-828X.1993.tb02113.x.

    CAS  PubMed  Google Scholar 

  36. Proud J, Grant AM: Third trimester placental grading by ultrasonography as a test of fetal wellbeing. Br Med J (Clin Res Ed). 1987, 294 (6588): 1641-1644. 10.1136/bmj.294.6588.1641.

    CAS  Google Scholar 

  37. Rouse DJ, Owen J, Goldenberg RL, Cliver SP: The effectiveness and costs of elective cesarean delivery for fetal macrosomia diagnosed by ultrasound. JAMA. 1996, 276 (18): 1480-1486. 10.1001/jama.276.18.1480.

    CAS  PubMed  Google Scholar 

  38. Reddy UM, Filly RA, Copel JA: Prenatal imaging: ultrasonography and magnetic resonance imaging. Obstet Gynecol. 2008, 112 (1): 145-157.

    PubMed Central  PubMed  Google Scholar 

  39. Papageorghiou AT, Leslie K: Uterine artery Doppler in the prediction of adverse pregnancy outcome. Curr Opin Obstet Gynecol. 2007, 19 (2): 103-109.

    PubMed  Google Scholar 

  40. FitzGerald DE, Drumm JE: Non-invasive measurement of human fetal circulation using ultrasound: a new method. Br Med J. 1977, 2 (6100): 1450-1451. 10.1136/bmj.2.6100.1450.

    PubMed Central  CAS  PubMed  Google Scholar 

  41. Theron GB, Pattinson RC: Management of patients with poor symphysis pubis-fundus growth by Doppler flow velocimetry of the umbilical artery – an effective method to detect the fetus at risk. Int J Gynaecol Obstet. 1992, 39 (2): 93-98. 10.1016/0020-7292(92)90903-V.

    CAS  PubMed  Google Scholar 

  42. Torres PJ, Gratacos E, Alonso PL: Umbilical artery Doppler ultrasound predicts low birth weight and fetal death in hypertensive pregnancies. Acta Obstet Gynecol Scand. 1995, 74 (5): 352-355. 10.3109/00016349509024427.

    CAS  PubMed  Google Scholar 

  43. Turan OM, Turan S, Gungor S, Berg C, Moyano D, Gembruch U, Nicolaides KH, Harman CR, Baschat AA: Progression of Doppler abnormalities in intrauterine growth restriction. Ultrasound Obstet Gynecol. 2008, 32 (2): 160-167. 10.1002/uog.5386.

    CAS  PubMed  Google Scholar 

  44. Papageorghiou AT, Yu CK, Cicero S, Bower S, Nicolaides KH: Second-trimester uterine artery Doppler screening in unselected populations: a review. J Matern Fetal Neonatal Med. 2002, 12 (2): 78-88. 10.1080/713605620.

    CAS  PubMed  Google Scholar 

  45. Smith GC, Yu CK, Papageorghiou AT, Cacho AM, Nicolaides KH: Maternal uterine artery Doppler flow velocimetry and the risk of stillbirth. Obstet Gynecol. 2007, 109 (1): 144-151.

    PubMed  Google Scholar 

  46. Subtil D, Goeusse P, Houfflin-Debarge V, Puech F, Lequien P, Breart G, Uzan S, Quandalle F, Delcourt YM, Malek YM: Randomised comparison of uterine artery Doppler and aspirin (100 mg) with placebo in nulliparous women: the Essai Regional Aspirine Mere-Enfant study (Part 2). BJOG. 2003, 110 (5): 485-491.

    CAS  PubMed  Google Scholar 

  47. Baschat AA, Gembruch U, Weiner CP, Harman CR: Qualitative venous Doppler waveform analysis improves prediction of critical perinatal outcomes in premature growth-restricted fetuses. Ultrasound Obstet Gynecol. 2003, 22 (3): 240-245. 10.1002/uog.149.

    CAS  PubMed  Google Scholar 

  48. Hugo EJ, Odendaal HJ, Grove D: Evaluation of the use of umbilical artery Doppler flow studies and outcome of pregnancies at a secondary hospital. J Matern Fetal Neonatal Med. 2007, 20 (3): 233-239. 10.1080/14767050601134926.

    PubMed  Google Scholar 

  49. Baschat AA: Doppler application in the delivery timing of the preterm growth-restricted fetus: another step in the right direction. Ultrasound Obstet Gynecol. 2004, 23 (2): 111-118. 10.1002/uog.989.

    CAS  PubMed  Google Scholar 

  50. Neilson JP, Alfirevic Z: Doppler ultrasound for fetal assessment in high risk pregnancies. Cochrane Database of Systematic Reviews. 1996, CD000073-4

  51. Alfirevic Z, Stampalija T, Gyte GML, Neilson JP: Fetal and umbilical Doppler ultrasound in high-risk pregnancies (Protocol). Cochrane Database of Systematic Reviews. 2009, CD007529-1

  52. Giles W, Bisits A, O'Callaghan S, Gill A: The Doppler assessment in multiple pregnancy randomised controlled trial of ultrasound biometry versus umbilical artery Doppler ultrasound and biometry in twin pregnancy. BJOG. 2003, 110 (6): 593-597. 10.1046/j.1471-0528.2003.02066.x.

    PubMed  Google Scholar 

  53. Divon MY, Ferber A: Doppler evaluation of the fetus. Clin Obstet Gynecol. 2002, 45 (4): 1015-1025. 10.1097/00003081-200212000-00008.

    PubMed  Google Scholar 

  54. Lees C, Baumgartner H: The TRUFFLE study – a collaborative publicly funded project from concept to reality: how to negotiate an ethical, administrative and funding obstacle course in the European Union. Ultrasound Obstet Gynecol. 2005, 25 (2): 105-107. 10.1002/uog.1836.

    CAS  PubMed  Google Scholar 

  55. Fine EA, Bracken M, Berkowitz RL: An evaluation of the usefulness of x-ray pelvimetry: comparison of the Thoms and modified Ball methods with manual pelvimetry. Am J Obstet Gynecol. 1980, 137 (1): 15-20.

    CAS  PubMed  Google Scholar 

  56. Pattinson RC, Farrell E: Pelvimetry for fetal cephalic presentations at or near term. Cochrane Database of Systematic Reviews. 1997, CD000161-2

  57. Parsons MT, Spellacy WN: Prospective randomized study of x-ray pelvimetry in the primigravida. Obstet Gynecol. 1985, 66 (1): 76-79.

    CAS  PubMed  Google Scholar 

  58. Crichton D: The accuracy and value of cephalopelvimetry. Journal of Obstetrics and Gynaecology of the British Commonwealth. 1962, 69: 366-378.

    Google Scholar 

  59. Richards A, Strang A, Moodley J, Philpott H: Vaginal delivery following caesarean section – is X-ray pelvimetry a reliable predictor?. Proceedings of 4th Conference on Priorities in Perinatal Care in South Africa: 1985.; Natal, South Africa. 1985, 62-65.

    Google Scholar 

  60. Macintosh MC, Fleming KM, Bailey JA, Doyle P, Modder J, Acolet D, Golightly S, Miller A: Perinatal mortality and congenital anomalies in babies of women with type 1 or type 2 diabetes in England, Wales, and Northern Ireland: population based study. BMJ. 2006, 333 (7560): 177-10.1136/bmj.38856.692986.AE.

    PubMed Central  PubMed  Google Scholar 

  61. Enkin M, Keirse MJNC, Neilson J, Crowther C, Duley L, Hodnett E, Hofmeyr GJ, editors: A guide to effective care in pregnancy and childbirth. 2000, Oxford: Oxford University Press, 3

  62. Casson IF, Clarke CA, Howard CV, McKendrick O, Pennycook S, Pharoah PO, Platt MJ, Stanisstreet M, van Velszen D, Walkinshaw S: Outcomes of pregnancy in insulin dependent diabetic women: results of a five year population cohort study. BMJ. 1997, 315 (7103): 275-278.

    PubMed Central  CAS  PubMed  Google Scholar 

  63. Jarrett RJ, Castro-Soares J, Dornhorst A, Beard RW: Should we screen for gestational diabetes?. BMJ. 1997, 315 (7110): 736-739.

    PubMed Central  CAS  PubMed  Google Scholar 

  64. Kinsley B: Achieving better outcomes in pregnancies complicated by type 1 and type 2 diabetes mellitus. Clin Ther. 2007, 29 (Suppl D): S153-160. 10.1016/j.clinthera.2007.12.015.

    CAS  PubMed  Google Scholar 

  65. Delgado Del Rey M, Herranz L, Martin Vaquero P, Janez M, Juan Lozano Garcia J, Darias R, Felipe Pallardo L: [Effect of preconceptional metabolic control in the course of pregnancy in diabetic patients]. Med Clin (Barc). 2001, 117 (2): 45-48.

    CAS  Google Scholar 

  66. Darias R, Herranz L, Garcia-Ingelmo MT, Pallardo LF: Pregnancy in a patient with type 1 diabetes mellitus and prior ischaemic heart disease. Eur J Endocrinol. 2001, 144 (3): 309-310. 10.1530/eje.0.1440309.

    CAS  PubMed  Google Scholar 

  67. Russell MA, Carpenter MW, Coustan DR: Screening and diagnosis of gestational diabetes mellitus. Clin Obstet Gynecol. 2007, 50 (4): 949-958. 10.1097/GRF.0b013e31815a5510.

    PubMed  Google Scholar 

  68. Broughton Pipkin F: Risk factors for preeclampsia. N Engl J Med. 2001, 344 (12): 925-926. 10.1056/NEJM200103223441209.

    CAS  PubMed  Google Scholar 

  69. Alberti KG, Zimmet PZ: Definition, diagnosis and classification of diabetes mellitus and its complications. Part 1: diagnosis and classification of diabetes mellitus provisional report of a WHO consultation. Diabet Med. 1998, 15 (7): 539-553. 10.1002/(SICI)1096-9136(199807)15:7<539::AID-DIA668>3.0.CO;2-S.

    CAS  PubMed  Google Scholar 

  70. Metzger BE, Buchanan TA, Coustan DR, de Leiva A, Dunger DB, Hadden DR, Hod M, Kitzmiller JL, Kjos SL, Oats JN, et al: Summary and recommendations of the Fifth International Workshop-Conference on Gestational Diabetes Mellitus. Diabetes Care. 2007, 30 (Suppl 2): S251-260. 10.2337/dc07-s225.

    CAS  PubMed  Google Scholar 

  71. American Diabetes Association.: Diagnosis and classification of diabetes mellitus. Diabetes Care. 2007, 29 (Suppl 1): S43-48.

    Google Scholar 

  72. ACOG Practice Bulletin. Clinical management guidelines for obstetrician-gynecologists. Number 30, September 2001 (replaces Technical Bulletin Number 200, December 1994). Gestational diabetes. Obstet Gynecol. 2001, 98 (3): 525-538.

  73. Tuffnell DJ, West J, Walkinshaw SA: Treatments for gestational diabetes and impaired glucose tolerance in pregnancy. Cochrane Database Syst Rev. 2003, CD003395-3

  74. Langer O, Rodriguez DA, Xenakis EM, McFarland MB, Berkus MD, Arrendondo F: Intensified versus conventional management of gestational diabetes. Am J Obstet Gynecol. 1994, 170 (4): 1036-1046. discussion 1046-1037

    CAS  PubMed  Google Scholar 

  75. Crowther CA, Hiller JE, Moss JR, McPhee AJ, Jeffries WS, Robinson JS: Effect of treatment of gestational diabetes mellitus on pregnancy outcomes. N Engl J Med. 2005, 352 (24): 2477-2486. 10.1056/NEJMoa042973.

    CAS  PubMed  Google Scholar 

  76. Gonzalez-Quintero VH, Istwan NB, Rhea DJ, Rodriguez LI, Cotter A, Carter J, Mueller A, Stanziano GJ: The impact of glycemic control on neonatal outcome in singleton pregnancies complicated by gestational diabetes. Diabetes Care. 2007, 30 (3): 467-470. 10.2337/dc06-1875.

    CAS  PubMed  Google Scholar 

  77. Banerjee S, Ghosh US, Banerjee D: Effect of tight glycaemic control on fetal complications in diabetic pregnancies. J Assoc Physicians India. 2004, 52: 109-113.

    CAS  PubMed  Google Scholar 

  78. McElvy SS, Miodovnik M, Rosenn B, Khoury JC, Siddiqi T, Dignan PS, Tsang RC: A focused preconceptional and early pregnancy program in women with type 1 diabetes reduces perinatal mortality and malformation rates to general population levels. J Matern Fetal Med. 2000, 9 (1): 14-20. 10.1002/(SICI)1520-6661(200001/02)9:1<14::AID-MFM5>3.0.CO;2-K.

    CAS  PubMed  Google Scholar 

  79. Huddle KR: Audit of the outcome of pregnancy in diabetic women in Soweto, South Africa, 1992 – 2002. S Afr Med J. 2005, 95 (10): 789-794.

    CAS  PubMed  Google Scholar 

  80. Landon MB, Langer O, Gabbe SG, Schick C, Brustman L: Fetal surveillance in pregnancies complicated by insulin-dependent diabetes mellitus. Am J Obstet Gynecol. 1992, 167 (3): 617-621.

    CAS  PubMed  Google Scholar 

  81. Mukhopadhyay A, Farrell T, Fraser RB, Ola B: Continuous subcutaneous insulin infusion vs intensive conventional insulin therapy in pregnant diabetic women: a systematic review and metaanalysis of randomized, controlled trials. Am J Obstet Gynecol. 2007, 197 (5): 447-456. 10.1016/j.ajog.2007.03.062.

    CAS  PubMed  Google Scholar 

  82. Hod M, Damm P, Kaaja R, Visser GH, Dunne F, Demidova I, Hansen AS, Mersebach H: Fetal and perinatal outcomes in type 1 diabetes pregnancy: a randomized study comparing insulin aspart with human insulin in 322 subjects. Am J Obstet Gynecol. 2008, 198 (2): 186-10.1016/j.ajog.2007.08.005. e181-187

    PubMed  Google Scholar 

  83. Aucott SW, Williams TG, Hertz RH, Kalhan SC: Rigorous management of insulin-dependent diabetes mellitus during pregnancy. Acta Diabetol. 1994, 31 (3): 126-129. 10.1007/BF00570364.

    CAS  PubMed  Google Scholar 

  84. Boulvain M, Stan C, Irion O: Elective delivery in diabetic pregnant women. Cochrane Database Syst Rev. 2001, CD001997-2

  85. Dudley DJ: Diabetic-associated stillbirth: incidence, pathophysiology, and prevention. Clin Perinatol. 2007, 34 (4): 611-626. 10.1016/j.clp.2007.09.003.

    PubMed  Google Scholar 

  86. O'Sullivan JB, Charles D, Mahan CM, Dandrow RV: Gestational diabetes and perinatal mortality rate. Am J Obstet Gynecol. 1973, 116 (7): 901-904.

    PubMed  Google Scholar 

  87. Solt I, Divon MY: Fetal surveillance tests. The Embryo: Scientific Discovery and Medical Ethics. Edited by: Blazer S, Zimmer EZ. 2005, Basel: Karger, 291-308.

    Google Scholar 

  88. Flynn AM, Kelly J, Mansfield H, Needham P, O'Conor M, Viegas O: A randomized controlled trial of non-stress antepartum cardiotocography. Br J Obstet Gynaecol. 1982, 89 (6): 427-433.

    CAS  PubMed  Google Scholar 

  89. Rayburn W, Greene J, Donaldson M: Nonstress testing and perinatal outcome. J Reprod Med. 1980, 24 (5): 191-196.

    CAS  PubMed  Google Scholar 

  90. Evertson LR, Gauthier RJ, Collea JV: Fetal demise following negative contraction stress tests. Obstet Gynecol. 1978, 51 (6): 671-673.

    CAS  PubMed  Google Scholar 

  91. Pattison N, McCowan L: Cardiotocography for antepartum fetal assessment. Cochrane Database of Systematic Reviews. 1999, CD001068-1

  92. Freeman RK, Anderson G, Dorchester W: A prospective multi-institutional study of antepartum fetal heart rate monitoring. II. Contraction stress test versus nonstress test for primary surveillance. Am J Obstet Gynecol. 1982, 143 (7): 778-781.

    CAS  PubMed  Google Scholar 

  93. Manning FA, Lange IR, Morrison I, Harman CR: Fetal biophysical profile score and the nonstress test: a comparative trial. Obstet Gynecol. 1984, 64 (3): 326-331.

    CAS  PubMed  Google Scholar 

  94. Freeman RK, Anderson G, Dorchester W: A prospective multi-institutional study of antepartum fetal heart rate monitoring. I. Risk of perinatal mortality and morbidity according to antepartum fetal heart rate test results. Am J Obstet Gynecol. 1982, 143 (7): 771-777.

    CAS  PubMed  Google Scholar 

  95. de la Vega A, Verdiales M: Failure of intensive fetal monitoring and ultrasound in reducing the stillbirth rate. P R Health Sci J. 2002, 21 (2): 123-125.

    PubMed  Google Scholar 

  96. Kennelly MM, Sturgiss SN: Management of small-for-gestational-age twins with absent/reversed end diastolic flow in the umbilical artery: outcome of a policy of daily biophysical profile (BPP). Prenat Diagn. 2007, 27 (1): 77-80. 10.1002/pd.1630.

    PubMed  Google Scholar 

  97. Golde SH, Montoro M, Good-Anderson B, Broussard P, Jacobs N, Loesser C, Trujillo M, Walla C, Phelan J, Platt LD: The role of nonstress tests, fetal biophysical profile, and contraction stress tests in the outpatient management of insulin-requiring diabetic pregnancies. Am J Obstet Gynecol. 1984, 148 (3): 269-273.

    CAS  PubMed  Google Scholar 

  98. Nageotte MP, Towers CV, Asrat T, Freeman RK: Perinatal outcome with the modified biophysical profile. Am J Obstet Gynecol. 1994, 170 (6): 1672-1676.

    CAS  PubMed  Google Scholar 

  99. Manning FA: Fetal biophysical profile. Obstet Gynecol Clin North Am. 1999, 26 (4): 557-577. 10.1016/S0889-8545(05)70099-1.

    CAS  PubMed  Google Scholar 

  100. Tongprasert F, Jinpala S, Srisupandit K, Tongsong T: The rapid biophysical profile for early intrapartum fetal well-being assessment. Int J Gynaecol Obstet. 2006, 95 (1): 14-17. 10.1016/j.ijgo.2006.05.015.

    CAS  PubMed  Google Scholar 

  101. Awad MM: The fetal biophysical profile score: a routine screening technique for pregnant women. J Egypt Soc Obstet Gynecol. 1991, 17 (1): 27-32.

    CAS  PubMed  Google Scholar 

  102. Tan KH, Smyth R: Fetal vibroacoustic stimulation for facilitation of tests of fetal wellbeing. Cochrane Database Syst Rev. 2001, CD002963-1

  103. Papadopoulos VG, Decavalas GO, Kondakis XG, Beratis NG: Vibroacoustic stimulation in abnormal biophysical profile: verification of facilitation of fetal well-being. Early Hum Dev. 2007, 83 (3): 191-197. 10.1016/j.earlhumdev.2006.05.014.

    PubMed  Google Scholar 

  104. Sood A: Vibroacoustic stimulation and modified fetal biophysical profile in high risk pregnancy. Journal of Obstetrics and Gynaecology of India. 2007, 57 (1): 27-36.

    Google Scholar 

  105. Harman CR: Amniotic fluid abnormalities. Semin Perinatol. 2008, 32 (4): 288-294. 10.1053/j.semperi.2008.04.012.

    PubMed  Google Scholar 

  106. Flack NJ, Fisk NM: Oligohydramnios and associated fetal complications. Fetal and Maternal Medicine Review. 1993, Cambridge University Press, 5:

    Google Scholar 

  107. Magann EF, Chauhan SP, Doherty DA, Lutgendorf MA, Magann MI, Morrison JC: A review of idiopathic hydramnios and pregnancy outcomes. Obstet Gynecol Surv. 2007, 62 (12): 795-802. 10.1097/01.ogx.0000290349.58707.e0.

    PubMed  Google Scholar 

  108. Ventolini G, Neiger R: Placental dysfunction: pathophysiology and clinical considerations. J Obstet Gynaecol. 2006, 26 (8): 728-730. 10.1080/01443610600955685.

    CAS  PubMed  Google Scholar 

  109. Stoll CG, Roth MP, Dott B, Alembik Y: Study of 290 cases of polyhydramnios and congenital malformations in a series of 225,669 consecutive births. Community Genet. 1999, 2 (1): 36-42. 10.1159/000016182.

    CAS  PubMed  Google Scholar 

  110. Phelan JP, Park YW, Ahn MO, Rutherford SE: Polyhydramnios and perinatal outcome. J Perinatol. 1990, 10 (4): 347-350.

    CAS  PubMed  Google Scholar 

  111. Magann EF, Isler CM, Chauhan SP, Martin JN: Amniotic fluid volume estimation and the biophysical profile: a confusion of criteria. Obstet Gynecol. 2000, 96 (4): 640-642. 10.1016/S0029-7844(99)00634-1.

    CAS  PubMed  Google Scholar 

  112. Mazor M, Ghezzi F, Maymon E, Shoham-Vardi I, Vardi H, Hershkowitz R, Leiberman JR: Polyhydramnios is an independent risk factor for perinatal mortality and intrapartum morbidity in preterm delivery. Eur J Obstet Gynecol Reprod Biol. 1996, 70 (1): 41-47. 10.1016/S0301-2115(96)02551-1.

    CAS  PubMed  Google Scholar 

  113. Dashe JS, McIntire DD, Ramus RM, Santos-Ramos R, Twickler DM: Hydramnios: anomaly prevalence and sonographic detection. Obstet Gynecol. 2002, 100 (1): 134-139. 10.1016/S0029-7844(02)02013-6.

    PubMed  Google Scholar 

  114. Erez O, Shoham-Vardi I, Sheiner E, Dukler D, Bashiri A, Mazor M: Hydramnios and small for gestational age are independent risk factors for neonatal mortality and maternal morbidity. Arch Gynecol Obstet. 2005, 271 (4): 296-301. 10.1007/s00404-004-0656-4.

    PubMed  Google Scholar 

  115. Anandakumar C, Biswas A, Arulkumaran S, Wong YC, Malarvishy G, Ratnam SS: Should assessment of amniotic fluid volume form an integral part of antenatal fetal surveillance of high risk pregnancy?. Aust N Z J Obstet Gynaecol. 1993, 33 (3): 272-275. 10.1111/j.1479-828X.1993.tb02084.x.

    CAS  PubMed  Google Scholar 

  116. Locatelli A, Zagarella A, Toso L, Assi F, Ghidini A, Biffi A: Serial assessment of amniotic fluid index in uncomplicated term pregnancies: prognostic value of amniotic fluid reduction. J Matern Fetal Neonatal Med. 2004, 15 (4): 233-236. 10.1080/14767050410001668671.

    CAS  PubMed  Google Scholar 

  117. Baron C, Morgan MA, Garite TJ: The impact of amniotic fluid volume assessed intrapartum on perinatal outcome. Am J Obstet Gynecol. 1995, 173 (1): 167-174. 10.1016/0002-9378(95)90185-X.

    CAS  PubMed  Google Scholar 

  118. Myles TD, Strassner HT: Four-quadrant assessment of amniotic fluid volume: distribution's role in predicting fetal outcome. Obstet Gynecol. 1992, 80 (5): 769-774.

    CAS  PubMed  Google Scholar 

  119. Youssef AA, Abdulla SA, Sayed EH, Salem HT, Abdelalim AM, Devoe LD: Superiority of amniotic fluid index over amniotic fluid pocket measurement for predicting bad fetal outcome. South Med J. 1993, 86 (4): 426-429. 10.1097/00007611-199304000-00011.

    CAS  PubMed  Google Scholar 

  120. Morris JM, Thompson K, Smithey J, Gaffney G, Cooke I, Chamberlain P, Hope P, Altman D, MacKenzie IZ: The usefulness of ultrasound assessment of amniotic fluid in predicting adverse outcome in prolonged pregnancy: a prospective blinded observational study. BJOG. 2003, 110 (11): 989-994. 10.1111/j.1471-0528.2003.02417.x.

    CAS  PubMed  Google Scholar 

  121. Nabhan AF, Abdelmoula YA: Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database of Systematic Reviews. 2007, CD006593-3

  122. Williams K, Wittmann B, Dansereau J: Intraobserver reliability of amniotic fluid volume estimation by two techniques: amniotic fluid index vs. maximum vertical pocket. Ultrasound Obstet Gynecol. 1993, 3 (5): 346-349. 10.1046/j.1469-0705.1993.03050346.x.

    CAS  PubMed  Google Scholar 

  123. Alfirevic Z, Luckas M, Walkinshaw SA, McFarlane M, Curran R: A randomised comparison between amniotic fluid index and maximum pool depth in the monitoring of post-term pregnancy. Br J Obstet Gynaecol. 1997, 104 (2): 207-211.

    CAS  PubMed  Google Scholar 

  124. Oral B, Gocen C, Ozbasar D: A comparison between two different ultrasonographic methods for assessing amniotic fluid volume in postterm pregnancies. Ondokuz Mayis Universitesi Tip Dergisi. 1999, 16 (3): 180-186.

    Google Scholar 

  125. Chauhan SP, Washburne JF, Magann EF, Perry KG, Martin JN, Morrison JC: A randomized study to assess the efficacy of the amniotic fluid index as a fetal admission test. Obstet Gynecol. 1995, 86 (1): 9-13. 10.1016/0029-7844(95)00110-D.

    CAS  PubMed  Google Scholar 

  126. Hofmeyr GJ, Gulmezoglu AM: Maternal hydration for increasing amniotic fluid volume in oligohydramnios and normal amniotic fluid volume. Cochrane Database Syst Rev. 2002, CD000134-1

  127. Crowther CA: Hospitalisation and bed rest for multiple pregnancy. Cochrane Database Syst Rev. 2001, CD000110-1

  128. Saunders MC, Dick JS, Brown IM, McPherson K, Chalmers I: The effects of hospital admission for bed rest on the duration of twin pregnancy: a randomised trial. Lancet. 1985, 2 (8459): 793-795. 10.1016/S0140-6736(85)90792-5.

    CAS  PubMed  Google Scholar 

  129. Crowther CA, Verkuyl DA, Ashworth MF, Bannerman C, Ashurst HM: The effects of hospitalization for bed rest on duration of gestation, fetal growth and neonatal morbidity in triplet pregnancy. Acta Genet Med Gemellol (Roma). 1991, 40 (1): 63-68.

    CAS  Google Scholar 

  130. Meher S, Abalos E, Carroli G: Bed rest with or without hospitalisation for hypertension during pregnancy. Cochrane Database Syst Rev. 2005, CD003514-4

  131. Monincx WM, Zondervan HA, Birnie E, Ris M, Bossuyt PM: High risk pregnancy monitored antenatally at home. Eur J Obstet Gynecol Reprod Biol. 1997, 75 (2): 147-153. 10.1016/S0301-2115(97)00122-X.

    CAS  PubMed  Google Scholar 

  132. [A method of evaluating self-monitoring at home during pregnancy]. Zhonghua Fu Chan Ke Za Zhi. 1990, 25 (3): 130-133.

  133. Crowther CA, Bouwmeester AM, Ashurst HM: Does admission to hospital for bed rest prevent disease progression or improve fetal outcome in pregnancy complicated by non-proteinuric hypertension?. Br J Obstet Gynaecol. 1992, 99 (1): 13-17.

    CAS  PubMed  Google Scholar 

  134. Soothill PW, Ajayi R, Campbell S, Gibbs J, Chandran R, Gibb D, Nicolaides KH: Effect of a fetal surveillance unit on admission of antenatal patients to hospital. BMJ. 1991, 303 (6797): 269-271. 10.1136/bmj.303.6797.269.

    PubMed Central  CAS  PubMed  Google Scholar 

  135. Kroner C, Turnbull D, Wilkinson C: Antenatal day care units versus hospital admission for women with complicated pregnancy. Cochrane Database Syst Rev. 2001, CD001803-4

  136. Tuffnell DJ, Lilford RJ, Buchan PC, Prendiville VM, Tuffnell AJ, Holgate MP, Jones MD: Randomised controlled trial of day care for hypertension in pregnancy. Lancet. 1992, 339 (8787): 224-227. 10.1016/0140-6736(92)90017-W.

    CAS  PubMed  Google Scholar 

  137. Grivell RM, Wong L, Bhatia V: Regimens of fetal surveillance for impaired fetal growth (Protocol). Cochrane Database ofSystematic Reviews. 2008, CD007113-2

  138. Menzies J, Magee LA, Li J, MacNab YC, Yin R, Stuart H, Baraty B, Lam E, Hamilton T, Lee SK, et al: Instituting surveillance guidelines and adverse outcomes in preeclampsia. Obstet Gynecol. 2007, 110 (1): 121-127.

    PubMed  Google Scholar 

  139. Lavender T, Malcolmson L: Is the partogram a help or a hindrance? An exploratory study of midwives' views. Pract Midwife. 1999, 2 (8): 23-27.

    CAS  PubMed  Google Scholar 

  140. Lavender T, Hart A, Smyth RM: Effect of partogram use onoutcomes for women in spontaneous labour at term. Cochrane Database Syst Rev. 2008, CD005461-4

  141. Walss Rodriguez RJ, Gudino Ruiz F, Tapia Rodriguez S: [Trial of labor. A comparative study between Friedman's partogram and the conventional descriptive partogram]. Ginecol Obstet Mex. 1987, 55: 318-322.

    CAS  PubMed  Google Scholar 

  142. Windrim R, Seaward G, Hodnett E, Akoury H, Kingdom J, Salenieks ME, et al: A randomized controlled trial of a bedside partogram in the active management of primiparous labour. Journal of Obstetrics and Gynaecology Canada. 2006, 29 (1): 27-34.

    Google Scholar 

  143. Lavender T, Alfirevic Z, Walkinshaw S: Partogram action line study: a randomised trial. Br J Obstet Gynaecol. 1998, 105 (9): 976-980.

    CAS  PubMed  Google Scholar 

  144. Lavender T, Alfirevic Z, Walkinshaw S: Effect of different partogram action lines on birth outcomes: a randomized controlled trial. Obstet Gynecol. 2006, 108 (2): 295-302.

    PubMed  Google Scholar 

  145. Pattinson RC, Howarth GR, Mdluli W, Macdonald AP, Makin JD, Funk M: Aggressive or expectant management of labour: a randomised clinical trial. BJOG. 2003, 110 (5): 457-461. 10.1046/j.1471-0528.2003.02298.x.

    CAS  PubMed  Google Scholar 

  146. World Health Organization partograph in management of labour. World Health Organization Maternal Health and Safe Motherhood Programme. Lancet. 1994, 343 (8910): 1399-1404.

  147. Lennox C: Active management of labour. WHO partogram helps. BMJ. 1994, 309 (6960): 1016-1017.

    PubMed Central  CAS  PubMed  Google Scholar 

  148. Fahdhy M, Chongsuvivatwong V: Evaluation of World Health Organization partograph implementation by midwives for maternity home birth in Medan, Indonesia. Midwifery. 2005, 21 (4): 301-310. 10.1016/j.midw.2004.12.010.

    PubMed  Google Scholar 

  149. East CE, Chan FY, Colditz PB, Begg LM: Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev. 2007, CD004075-2

  150. Royal College of Obstetricians and Gynaecologists: The use of electronic fetal monitoring. The use and interpretation of cardiotocography in intrapartum fetal surveillance. Evidence-based Clinical Guideline Number 8. 2001, London: RCOG Press

    Google Scholar 

  151. Colditz PB, Begg LM, East CE: Fetal pulse oximetry. Instrumentation and recent clinical experience. Clin Perinatol. 1999, 26 (4): 869-880.

    CAS  PubMed  Google Scholar 

  152. Kuhnert M, Seelbach-Goebel B, Butterwegge M: Predictive agreement between the fetal arterial oxygen saturation and fetal scalp pH: results of the German multicenter study. Am J Obstet Gynecol. 1998, 178 (2): 330-335. 10.1016/S0002-9378(98)80021-5.

    CAS  PubMed  Google Scholar 

  153. Devane D, Lalor JG, Daly S, McGuire W: Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing. (Protocol). Cochrane Database of Systematic Reviews. 2005, CD005122-1

  154. Neilson JP: Fetal electrocardiogram (ECG) for fetal monitoring during labour. Cochrane Database Syst Rev. 2006, 3: CD000116-

    PubMed  Google Scholar 

  155. Fretts RC, Boyd ME, Usher RH, Usher HA: The changing pattern of fetal death, 1961–1988. Obstet Gynecol. 1992, 79 (1): 35-39.

    CAS  PubMed  Google Scholar 

  156. Smith J, Wells L, Dodd K: The continuing fall in incidence of hypoxic-ischaemic encephalopathy in term infants. BJOG. 2000, 107 (4): 461-466. 10.1111/j.1471-0528.2000.tb13262.x.

    CAS  PubMed  Google Scholar 

  157. Kalter H: Five-decade international trends in the relation of perinatal mortality and congenital malformations: stillbirth and neonatal death compared. Int J Epidemiol. 1991, 20 (1): 173-179. 10.1093/ije/20.1.173.

    CAS  PubMed  Google Scholar 

  158. Smith GC, Fretts RC: Stillbirth. Lancet. 2007, 370 (9600): 1715-1725. 10.1016/S0140-6736(07)61723-1.

    PubMed  Google Scholar 

  159. Smith GC, Crossley JA, Aitken DA, Pell JP, Cameron AD, Connor JM, Dobbie R: First Trimester Placentation and Risk of Antepartum Stillbirth. JAMA. 2004, 292: 2249-2254. 10.1001/jama.292.18.2249.

    CAS  PubMed  Google Scholar 

  160. Stanton C, Lawn JE, Rahman H, Wilczynska-Ketende K, Hill K: Stillbirth rates: delivering estimates in 190 countries. The Lancet. 2006, 367: 1487-1494. 10.1016/S0140-6736(06)68586-3.

    Google Scholar 

  161. Grivell RM, Wong L, Bhatia V: Regimens of fetal surveillance for impaired fetal growth. Cochrane Database of Systematic Reviews. 2009, CD007113-1

  162. Baschat AA, Galan HL, Bhide A, Berg C, Kush ML, Oepkes D, Thilaganathan B, Gembruch U, Harman CR: Doppler and biophysical assessment in growth restricted fetuses: distribution of test results. Ultrasound Obstet Gynecol. 2006, 27 (1): 41-47. 10.1002/uog.2657.

    CAS  PubMed  Google Scholar 

  163. Cho CH: [The identification of high-risk pregnancy, using a simplified antepartum risk-scoring system]. Taehan Kanho. 1991, 30 (3): 49-65.

    CAS  PubMed  Google Scholar 

  164. Mikulandra F, Merlak I, Perisa M, Konjevoda M, Glavadanovic N: [Scoring of risk factors in pregnancy, labor and in the early neonatal period]. Jugosl Ginekol Perinatol. 1986, 26 (1–2): 15-21.

    CAS  PubMed  Google Scholar 

  165. Morrison I, Carter L, McNamara S, Cheang M: A simplified intrapartum numerical scoring system. The prediction of high risk in labor. Am J Obstet Gynecol. 1980, 138 (2): 175-180.

    CAS  PubMed  Google Scholar 

  166. Gomez LM, De la Vega G, Padilla L, Bautista F, Villar A: Compliance with a fetal movement chart by high-risk obstetric patients in a Peruvian hospital. Am J Perinatol. 2007, 24 (2): 89-93. 10.1055/s-2006-958160.

    PubMed  Google Scholar 

  167. van Dyk B, Motto JA, Buchmann EJ: Routine second-trimester ultrasound for low risk pregnancies in a South African community. Int J Gynaecol Obstet. 2007, 98 (3): 257-258. 10.1016/j.ijgo.2007.03.034.

    CAS  PubMed  Google Scholar 

  168. Cristina MP, Ana G, Ines T, Manuel GE, Enrique IG: Perinatal results following the prenatal ultrasound diagnosis of single umbilical artery. Acta Obstet Gynecol Scand. 2005, 84 (11): 1068-1074. 10.1111/j.0001-6349.2005.00884.x.

    Google Scholar 

  169. Sylvan K, Ryding EL, Rydhstroem H: Routine ultrasound screening in the third trimester: a population-based study. Acta Obstet Gynecol Scand. 2005, 84 (12): 1154-1158. 10.1111/j.0001-6349.2005.00649.x.

    PubMed  Google Scholar 

  170. Viero S, Chaddha V, Alkazaleh F, Simchen MJ, Malik A, Kelly E, Windrim R, Kingdom JC: Prognostic value of placental ultrasound in pregnancies complicated by absent end-diastolic flow velocity in the umbilical arteries. Placenta. 2004, 25 (8–9): 735-741. 10.1016/j.placenta.2004.03.002.

    CAS  PubMed  Google Scholar 

  171. A randomised controlled trial of Doppler ultrasound velocimetry of the umbilical artery in low risk pregnancies. Doppler French Study Group. Br J Obstet Gynaecol. 1997, 104 (4): 419-424.

  172. Davies JA, Gallivan S, Spencer JA: Randomised controlled trial of Doppler ultrasound screening of placental perfusion during pregnancy. Lancet. 1992, 340 (8831): 1299-1303. 10.1016/0140-6736(92)92490-7.

    CAS  PubMed  Google Scholar 

  173. Whittle MJ, Hanretty KP, Primrose MH, Neilson JP: Screening for the compromised fetus: a randomized trial of umbilical artery velocimetry in unselected pregnancies. Am J Obstet Gynecol. 1994, 170 (2): 555-559.

    CAS  PubMed  Google Scholar 

  174. Bancroft K, Tuffnell DJ, Mason GC, Rogerson LJ, Mansfield M: A randomised controlled pilot study of the management of gestational impaired glucose tolerance. BJOG. 2000, 107 (8): 959-963. 10.1111/j.1471-0528.2000.tb10396.x.

    CAS  PubMed  Google Scholar 

  175. Karmon A, Levy A, Holcberg G, Wiznitzer A, Mazor M, Sheiner E: Decreased perinatal mortality among women with diet-controlled gestational diabetes mellitus. Int J Gynaecol Obstet. 2009, 104 (3): 199-202. 10.1016/j.ijgo.2008.09.016.

    PubMed  Google Scholar 

  176. Fadel HE, Hammond SD: Diabetes mellitus and pregnancy: management and results. J Reprod Med. 1982, 27 (2): 56-66.

    CAS  PubMed  Google Scholar 

  177. Nachum Z, Ben-Shlomo I, Weiner E, Ben-Ami M, Shalev E: Diabetes in pregnancy: efficacy and cost of hospitalization as compared with ambulatory management – a prospective controlled study. Isr Med Assoc J. 2001, 3 (12): 915-919.

    CAS  PubMed  Google Scholar 

  178. Petrovic O, Skunca E, Matejcic N: A simplified fetal biophysical profile. Int J Gynaecol Obstet. 1998, 61 (1): 9-14. 10.1016/S0020-7292(98)00009-5.

    CAS  PubMed  Google Scholar 

  179. Salamalekis E, Vitoratos N, Loghis C, Mortakis A, Zourlas PA: The predictive value of a nonstress test taken 24 h before delivery in high-risk pregnancies. Int J Gynaecol Obstet. 1994, 45 (2): 105-107. 10.1016/0020-7292(94)90116-3.

    CAS  PubMed  Google Scholar 

  180. Kreiser D, el-Sayed YY, Sorem KA, Chitkara U, Holbrook RH, Druzin ML: Decreased amniotic fluid index in low-risk pregnancy. J Reprod Med. 2001, 46 (8): 743-746.

    CAS  PubMed  Google Scholar 

  181. Sherer DM, Spong CY, Minior VK, Salafia CM: Decreased amniotic fluid volume at < 32 weeks of gestation is associated with decreased fetal movements. Am J Perinatol. 1996, 13 (8): 479-482. 10.1055/s-2007-994431.

    CAS  PubMed  Google Scholar 

  182. Shoham I, Wiznitzer A, Silberstein T, Fraser D, Holcberg G, Katz M, Mazor M: Gestational diabetes complicated by hydramnios was not associated with increased risk of perinatal morbidity and mortality. Eur J Obstet Gynecol Reprod Biol. 2001, 100 (1): 46-49. 10.1016/S0301-2115(01)00426-2.

    CAS  PubMed  Google Scholar 

  183. Seelbach-Gobel B, Heupel M, Kuhnert M, Butterwegge M: The prediction of fetal acidosis by means of intrapartum fetal pulse oximetry. Am J Obstet Gynecol. 1999, 180 (1 Pt 1): 73-81. 10.1016/S0002-9378(99)70153-5.

    CAS  PubMed  Google Scholar 

  184. Stiller R, von Mering R, Konig V, Huch A, Huch R: How well does reflectance pulse oximetry reflect intrapartum fetal acidosis?. Am J Obstet Gynecol. 2002, 186 (6): 1351-1357. 10.1067/mob.2002.122411.

    PubMed  Google Scholar 

  185. Nabhan AF, Abdelmoula YA: Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database Syst Rev. 2008, CD006593-3

Download references

Acknowledgements

This series was supported by the Saving Newborn Lives programme of Save the Children-US through a grant from the Bill & Melinda Gates Foundation.

This article has been published as part of BMC Pregnancy and Childbirth Volume 9 Supplement 1, 2009: Stillbirths – the global picture and evidence-based solutions. The full contents of the supplement are available online at http://www.biomedcentral.com/1471-2393/9?issue=S1.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zulfiqar A Bhutta.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

The paper was written and reviewed by all the authors.

Electronic supplementary material

12884_2009_262_MOESM1_ESM.doc

Additional file 1: Web Table 1. Component studies in Mangesi and Hofmeyr 2007 meta-analysis: Impact of fetal movement monitoring. Component studies in Mangesi et al. 2007 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 36 KB)

12884_2009_262_MOESM2_ESM.doc

Additional file 2: Web Table 2. Component studies in Neilson 1998 meta-analysis: Impact of routine ultrasound in pregnancy. Component studies in Neilson 1998 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 66 KB)

12884_2009_262_MOESM3_ESM.doc

Additional file 3: Web Table 3. Component studies in Bricker et al. 2008 meta-analysis: Impact of ultrasound in late pregnancy. Component studies in Bricker et al. 2008 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 60 KB)

12884_2009_262_MOESM4_ESM.doc

Additional file 4: Web Table 4. Component studies in Papageorghiou et al. 2002: Impact of second trimester uterine artery Doppler on perinatal mortality. Component studies in Papageorghiou et al. 2002 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 84 KB)

12884_2009_262_MOESM5_ESM.doc

Additional file 5: Web Table 5. Component studies in Baschat 2004: impact of Doppler velocimetry on stillbirth and perinatal mortality in pre-term growth-restricted fetuses. Component studies in Baschat 2004 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 75 KB)

12884_2009_262_MOESM6_ESM.doc

Additional file 6: Web Table 6. Component studies in Neilson et al. 2000 meta-analysis: Impact of Doppler screening during pregnancy. Component studies in Neilson et al. 2000 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 58 KB)

12884_2009_262_MOESM7_ESM.doc

Additional file 7: Web Table 7. Component studies in Pattinson and Farrell 1997 meta-analysis: Impact of pelvimetry during pregnancy. Component studies in Pattinson et al. 1997 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 40 KB)

12884_2009_262_MOESM8_ESM.doc

Additional file 8: Web Table 8. Component studies in Russell et al. 2007 meta-analysis: Impact of management of gestational diabetes on stillbirth and perinatal outcomes. Component studies in Russell et al. 2007 showing impact on stillbirths/perinatal mortality (DOC 30 KB)

12884_2009_262_MOESM9_ESM.doc

Additional file 9: Web Table 9. Component studies in Mukhopadhyay et al. 2007: Impact of continuous subcutaneous insulin infusion on intrauterine fetal death. Component studies in Mukhopadhyay et al. 2007 showing impact on stillbirths/perinatal mortality (DOC 37 KB)

12884_2009_262_MOESM10_ESM.doc

Additional file 10: Web Table 10. Component studies in Boulvain et al. 2001 meta-analysis: Impact of elective delivery on perinatal mortality. Component studies in Boulvain et al. 2001 showing impact on stillbirths/perinatal mortality (DOC 31 KB)

12884_2009_262_MOESM11_ESM.doc

Additional file 11: Web Table 11. Component studies in Pattison and McCowan 1999 meta-analysis: Impact of cardiotocography for antepartum fetal assessment on perinatal mortality. Component studies in Pattison and McCowan 1999 showing impact on stillbirths/perinatal mortality (DOC 26 KB)

12884_2009_262_MOESM12_ESM.doc

Additional file 12: Web Table 12. Component studies in Lalor et al. 2008 meta-analysis: Impact of fetal biophysical profile. Component studies in Lalor et al. 2008 showing impact on stillbirths/perinatal mortality (DOC 45 KB)

12884_2009_262_MOESM13_ESM.doc

Additional file 13: Web Table 13. Component studies in Tan et al. 2001 meta-analysis: Impact of vibroacoustic stimulation. Component studies in Tan et al. 2001 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 62 KB)

12884_2009_262_MOESM14_ESM.doc

Additional file 14: Web Table 14. Component studies in Magann et al 2007 review: impact of idiopathic polyhydramnios on stillbirth and perinatal mortality. Component studies in Magann et al. 2007 review showing impact on stillbirths/perinatal mortality (DOC 44 KB)

12884_2009_262_MOESM15_ESM.doc

Additional file 15: Web Table 15. Component studies in Nabhan and Abdelmoula 2008 [185]meta-analysis: comparison of single deepest vertical pocket vs. AFI in predicting perinatal outcome. Component studies in Nabhan and Abdelmoula 2008 review showing impact on stillbirths/perinatal mortality (DOC 32 KB)

12884_2009_262_MOESM16_ESM.doc

Additional file 16: Web Table 16. Component studies in Hofmeyr and Gulmezoglu 2002 [126]meta-analysis: impact of maternal hydration on amniotic fluid volume and perinatal outcomes. Component studies in Hofmeyr and Gulmezoglu 2002 review showing impact on stillbirths/perinatal mortality (DOC 49 KB)

12884_2009_262_MOESM17_ESM.doc

Additional file 17: Web Table 17. Component studies in Crowther 2001 meta-analysis: Impact of hospitalisation for bed rest for women with a multiple pregnancy on stillbirth and perinatal mortality. Component studies in Crowther 2001 review showing impact on stillbirths/perinatal mortality (DOC 52 KB)

12884_2009_262_MOESM18_ESM.doc

Additional file 18: Web Table 18. Component studies in Meher et al. 2005: Impact of some rest in hospital vs. routine activity at home on stillbirth and perinatal mortality. Component studies in Meher et al. 2005 review showing impact on stillbirths/perinatal mortality (DOC 32 KB)

12884_2009_262_MOESM19_ESM.doc

Additional file 19: Component studies in Kroner et al. 2001: Impact of antenatal day care units on perinatal mortality. Component studies in Kroner et al. 2001 review showing impact on stillbirths/perinatal mortality (DOC 32 KB)

12884_2009_262_MOESM20_ESM.doc

Additional file 20: Web Table 20. Component studies in Lavender et al. 2008 meta-analysis: Impact of different designs of partogram on neonatal morbidity or perinatal mortality. Component studies in Lavender et al. 2008 review showing impact on stillbirths/perinatal mortality (DOC 38 KB)

12884_2009_262_MOESM21_ESM.doc

Additional file 21: Web Table 21. Component studies in Alfirevic and Devane 2006 meta-analysis: Impact of continuous cardiotocography on stillbirth and perinatal mortality. Component studies in Lavender et al. 2008 review showing impact on stillbirths/perinatal mortality (DOC 104 KB)

12884_2009_262_MOESM22_ESM.doc

Additional file 22: Web Table 22. Component studies in Neilson 2006 meta-analysis: Impact of fetal electrocardiogram (ECG) on perinatal mortality. Component studies in Neilson meta-analysis showing impact on stillbirths/perinatal mortality (DOC 44 KB)

12884_2009_262_MOESM23_ESM.doc

Additional file 23: Web Table 23. Component studies in East et al. 2007 meta-analysis: Impact of fetal pulse oximetry on fetal/neonatal death. Component studies in East et al. 2007 meta-analysis showing impact on stillbirths/perinatal mortality (DOC 38 KB)

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Haws, R.A., Yakoob, M.Y., Soomro, T. et al. Reducing stillbirths: screening and monitoring during pregnancy and labour. BMC Pregnancy Childbirth 9 (Suppl 1), S5 (2009). https://doi.org/10.1186/1471-2393-9-S1-S5

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1471-2393-9-S1-S5

Keywords