Skip to main content
  • Research article
  • Open access
  • Published:

Dynamic cardiac dyssynchrony is strongly associated with 2-year dialysis adequacy in continuous ambulatory peritoneal dialysis patients

Abstract

Background

Left ventricular (LV) dyssynchrony is associated with increased risk of all-cause mortality in patients with end-stage renal disease. Our aim was to determine the associations of LV dynamic dyssynchrony with peritoneal solute clearance in continuous ambulatory peritoneal dialysis (CAPD) patients. Our primary objective was to determine the association between dynamic LV dyssynchrony and CAPD clearance at 2 years. Secondary objectives were to identify the factors influencing dynamic dyssynchrony, and to examine the association between dialysis adequacy and echocardiography-assessed LV outcomes.

Methods

Fifty CAPD patients and 13 healthy volunteers underwent three-dimensional (3D) dobutamine stress echocardiography (DSE). The main endpoint was systolic dyssynchrony index (SDI). Secondary endpoints, including NT-proBNP, troponin I, Kt/V, and biochemical parameters, were measured before stress echocardiography, and Kt/V was measured again 2 years later. All values are expressed as medians and interquartile ranges (IQR).

Results

NT-proBNP (3872 [808–11779] vs. 4.99 [4.99–36.83] pg/mL, P < 0.001), and log NT-proBNP (3.587 [2.896–4.071] vs. 0.698 [0.698–1.540], P < 0.001) levels were significantly higher in the CAPD group than in the control group. Real-time 3D DSE showed that the systolic dyssynchrony index was significantly different between the two groups at the peak dobutamine stage (1.11% [0.76–1.64%] vs. 0.66% [0.50–1.02%], P = 0.004), but not at resting (1.30% [0.89–1.74%] vs. 1.22 % [0.72–1.68%], P = 0.358).The subgroup of patients in the CAPD group with greater improvements in dialysis adequacy had lower baseline dynamic SDI and more favorable echocardiographic findings at 2 years. Dialysis adequacy decreased significantly at 2 year in patients with higher, but not in those with lower dynamic SDI at baseline. In multivariate linear regression analysis, log NT-proBNP and SDI at the peak dobutamine dose were significantly associated with Kt/V and weekly creatinine clearance at 2 years, while log NT-proBNP was significant associated with SDI at the peak dobutamine stage. Female CAPD patients group had more pronounced dynamic LV dyssynchrony compared with male patients.

Conclusions

Dynamic systolic dyssynchrony was strongly associated with future dialysis adequacy in CAPD patients. Log NT-proBNP was the important predictor of dynamic dyssynchrony. Our study confirmed the concept that cardiac dysfunction has an impact on dialysis adequacy.

Peer Review reports

Background

Solutes are transported from peritoneal capillaries to the dialysate by diffusion and convection processes. Diffusion is the most important transport mechanism for low molecular weights solutes [1]. Recent studies have demonstrated that transperitoneal clearance of small solutes is limited by the rate of blood flow during peritoneal dialysis [2]. The local renin–angiotensin–aldosterone system (RAAS), which regulates cardiac hemodynamic status and hypertension, plays an important role in the fibrotic process [3].

Therefore, we hypothesized that cardiac dysfunction is associated with small solute clearance in continuous ambulatory peritoneal dialysis (CAPD) patients.

Left ventricular (LV) compliance is an important determinant of LV function and can be affected by a variety of cardiovascular conditions. Diastolic dysfunction is also associated with altered LV compliance [4]. Transthoracic three-dimensional echocardiography (3DE) confirmed the feasibility of noninvasive estimation of the end-diastolic pressure–volume relationship. 3DE was also able to differentiate normal from abnormal LV compliance, which may be difficult or impossible to do using conventional 2DE [5].

N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels are correlated with LV wall stress, sphericity index (SI), and the extent of myocardial damage in patients with coronary artery disease (CAD), and with volume overload in heart failure. NT-proBNP is also an independent predictor of mortality in patients with ESRD [68]. However, no studies have examined whether NT-ProBNP can serve as a surrogate marker for dynamic LV dyssynchrony.

From this context, the main objective of this study was to investigate the association between LV dynamic dyssynchrony and CAPD clearance 2 years later. Our secondary objectives were to identify which factors influence dynamic dyssynchrony and to determine the association between dialysis adequacy and echocardiography-determined LV outcomes.

Methods

Subjects

Fifty uremic subjects on CAPD and 13 healthy volunteers were recruited from Changhua Christian Hospital, Changhua, Taiwan, between 2008 and 2011. All of the subjects were aged > 18 years and had normal sinus rhythm. None of the subjects in the control group were taking any medications. Subjects with acute coronary syndrome, a history of myocardial infarction, acute heart failure, congenital heart disease, severe valvular heart disease, or severe uncontrolled hypertension (systolic blood pressure [SBP] ≥ 210 mmHg or diastolic blood pressure [DBP] ≥ 110 mmHg) were excluded. Subjects with recent (< 3 months) peritonitis, other technique failure, or recent hospitalization were also excluded.

All CAPD patients received 2 L of 5% glucose peritoneal dialysate (Dianeal®; Baxter, Singapore) during transthoracic 3DE. The calculated peritoneal creatinine clearance rate was normalized to 1.73 m2 of the body surface area, and residual function was also taken into account. Membrane transport status was analyzed using a standard 4-h peritoneal equilibration test (PET). Dialysis adequacy was calculated as Kt/V, where K = dialyzer clearance of urea, t = dialysis time, and V = volume distribution of urea.

The protocol was approved by Institutional Review Board and the Ethics Committee of the Changhua Christian Hospital, Taiwan. All enrolled subjects provided written informed consent.

Dobutamine stress echocardiography (DSE)

Subjects underwent a standard dobutamine stress protocol, under continuous electrocardiography monitoring, with infusions of 5, 10, 20, 30, and 40 μg/kg/min dobutamine for 3 min at each stage. Heart rate and BP were recorded at baseline, during each stage, and during recovery (3 min after termination of infusion). Endpoints for study termination were extensive new wall motion abnormalities, attainment of the target heart rate (85% of the maximal heart rate predicted for age), or completion of the protocol. Images were acquired at baseline, during the final minute of each stage, and during recovery. All images were acquired by the same cardiologist.

Real-time (RT)3DE

RT3DE images were obtained with an IE33 xMATRIX echocardiography system (Philips Medical Systems, Andover, MA) and an X3-1 transducer (2–4 MHz) using secondary harmonic imaging. RT3DE images were acquired from the apical window immediately after the acquisition of 2DE images at each stage using another IE33 machine. Full-volume LV datasets were obtained for offline analysis using a QLab system (Philip Medical Systems). LV datasets were divided into 16 segments, excluding the apex, as recommended by the American Society of Echocadiography [9].

We used the dyssynchrony index, as previously described by Kapetanakis et al [10]. The systolic dyssynchrony index (SDI) was defined as the standard deviation of the time-to-minimum systolic volume of 16 LV segments expressed as a percentage of the R–R duration.

2DE

All 2DE parameters were measured using techniques recommended by the American Society of Echocadiography [9]. Systolic wall stress before dobutamine stress echocardiography (DSE) was calculated according to the formula of Grossman et al [11]. Left atrial (LA) volume was calculated using the biplane area–length method using 4- and 3-chamber views [4].

Measurement of NT-proBNP and troponin I levels

Fasting (≥8 h) venous blood samples (4 mL) were obtained before starting DSE. NT-proBNP was measured using an immunoassay (ECLIA; Roche Diagnostics GmbH, Mannheim, Germany), and troponin I was measured using a chemiluminescent immunoassay (Access AccuTnI assay; Beckman Coulter Inc., Brea, CA). NT-proBNP levels were logarithmically transformed before statistical analyses because the values were not normally distributed.

Statistical analysis

All statistical procedures were performed using SPSS software version 15.0 (SPSS Inc., Chicago, IL). All values are expressed as medians (interquartile range, IQR) Intergroup differences were determined using the Mann–Whitney test and P values < 0.05 were considered to be statistically significant. Intragroup differences (i.e., baseline vs. 2 years) were evaluated using the Mann–Whitney test and Wilcoxon test. Spearman’s ρ correlation and multivariate linear regression analyses were used to determine the associations between echocardiographic parameters and dialysis adequacy. Parameters showing significant correlations in univariate analyses and those with clinical relevance were then included in stepwise multiple linear regression analysis.

Intraobserver and interobserver variability

Intraobserver variability was determined by repeating the offline 3DE measurements of SDI at 2 weeks after baseline in all subjects. Interobserver variability was determined by comparison of all offline measurements by two cardiologists who were blinded to each other’s interpretations. Variability values were calculated as the absolute difference between the corresponding measurements in terms of the mean percentage.

Results

Subject characteristics

Table 1 summarizes the characteristics of CAPD patients and the healthy volunteers. Both groups were matched for BMI, age, and sex. NT-proBNP (3872 [808–11779] vs.4.99 [4.99–36.83] pg/mL, P < 0.001), log NT-proBNP (3.587 [2.896–4.071] vs. 0.698 [0.698–1.540] P < 0.001), and systolic wall stress (61.7 [43.11–100.0] vs. 40.5 [29.6–48.6] mmHg, P = 0.001) values were significantly higher in the CAPD group than control group. RT3DE showed evidence of dynamic systolic dyssynchrony in the CAPD group. SDI was significantly different between the two groups, but only at the peak dobutamine dose (1.11% [0.76–1.64%] vs. 0.66% [0.50–1.02%], P = 0.004).

Table 1 Subject characteristics

Evaluation of SDI at the peak stage of DSE and 2-year Kt/V in CAPD patients

One subject who underwent kidney transplantation and one subject who switched to hemodialysis were excluded from the follow-up study. The other 48 subjects in the CAPD group underwent follow-up 2DE and resting 3DE 2 years after the original examinations. Positive values for 2-year Kt/V – baseline Kt/V (ΔKt/V) indicated better clearance function. Patients with a positive ΔKt/V value had lower values of the LV mass index (MI), LV end-diastolic volume (EDV) index, and LV end-systolic volume (ESV) index, as well as lower SDI at the peak stage of DSE, as compared with patients with a negative ΔKt/V value (Table 2). The median SDI in the CAPD group at the peak dobutamine dose was 1.1%. Using this as a reference value, CAPD patients were divided into two subgroups according to SDI at the peak dobutamine dose as having high (i.e., >1.1%) or low (≤1.1%) dynamic SDI. The data are shown in Table 3. Dialysis adequacy at 2 years had decreased significantly from baseline in the high SDI subgroup, but not in the low SDI subgroup. We found no significant difference in troponin I concentrations between patients with low or high SDI (0.025 [0.09–0.05] vs. 0.035 [0.009–0.05] mg/mL, P = 0.247).

Table 2 Kt/V and echocardiographic parameters at baseline and at 2 years
Table 3 Change in dialysis adequacy indices change and SDI at peak DSE

Factors influencing dialysis adequacy at 2 years

Multivariate linear regression analysis revealed that log NT-proBNP, SDI at peak dobutamine dose, sex, and systolic wall stress were independently associated with Kt/V at 2 years (Table 4). Multiple linear regression analysis identified log NT-proBNP, SDI at peak dobutamine dose, age are independent predictors of weekly creatinine clearance at 2 years (Table 5).

Table 4 Multivariate regression analysis with Kt/V at 2 years as the dependent variable
Table 5 Multivariate regression analysis with WCC at 2 years as the dependent variable

Factors influencing dynamic dyssynchrony

Multivariate linear regression analysis showed that log NT-proBNP and sex were independently associated with SDI at peak dobutamine dose (Table 6).

Table 6 Multivariate regression analysis with SDI at peak DSE as the dependent variable

Intraobserver and interobserver variability

The interobserver variability for SDI was 6.3%, while intraobserver variability was 5.7%.

Discussion

DSE is a useful tool for evaluating cardiovascular risk in ESRD patients who are potential candidates for renal transplantation [12]. It also provides a comprehensive assessment of changes in echocardiographic parameters during each stage by using novel 3D echocardiographic tools [13]. 3D DSE is now widely considered as an alternative to exercise testing to accurately and reproducibly assess dynamic LV dyssynchrony [14]. Here, we report novel results showing that CAPD patients have more obvious LV systolic dyssynchrony in response to dobutamine stress, despite normal LVEF and similar resting dyssynchrony index, compared with healthy individuals. The difference in stress-induced dyssynchrony between CAPD patients and healthy controls is probably caused by LV hypertrophy (LVH) in the former, as CAPD patients are more likely to develop LVH. LVH is associated with increased myocardial oxygen demand and abnormal coronary flow, and may result in subendocardial ischemia or regional dysfunction during stress [15]. Differences in volume status may also be responsible for the difference, as volume overload is more common in CAPD patients than in the normal population [16]. Additionally, previous reports revealed that volume status may modulate LV dyssynchrony [17, 18]. Aljaroudi et al. reported that, among patients with ESRD, the prevalence of all-cause mortality is higher in patient with than in those without LV dyssynchrony [19]. A greater degree of dyssynchrony increased the 2-year mortality rate by 4–7-fold in patients free of high-risk features such as depressed LVEF, wide QRS, increased LV mass, or a large perfusion defect. Their study highlights the importance of cardiac dyssynchrony in terms of its detrimental effects on prognosis. We are eager to known whether its detrimental effects on prognosis are mediated by dialysis adequacy or cardiac structure.

An earlier study revealed that cardiac structure and function are influenced by uremic status and adequate dialysis therapy in pediatric CAPD patients; however, that was a cross-sectional study rather than a longitudinal study [20]. It is unknown whether cardiac function has an impact on long-term dialysis adequacy. So far, there are no data showing which echocardiographic parameters can predict long-term dialysis adequacy. In our longitudinal study, we clearly showed that dynamic dyssynchrony (SDI at peak DSE) and logNT-proBNP were significantly associated with indices of dialysis adequacy at 2 years (Kt/V and WCC; as shown in Tables 4 and 5). In patients with low dynamic SDI, the dialysis adequacy indices did not change significantly. However, in patients with high dynamic SDI, the dialysis adequacy indices tended to deteriorate over time, as shown in Table 3. A possible explanation for the dynamic dyssynchrony-induced deterioration of dialysis adequacy is as following. Stress-induced dyssynchrony may decrease the forward stroke volume, decreasing blood flow to the peritoneal capillaries responsible for solute clearance. This was observed in heart failure subjects with preserved ejection fraction [21]. The clinical scenario is very similar in CAPD patients who often have LV hypertrophy but preserved ejection fraction. Because we only included non-ischemic patients in this study, we did not observe a significant difference in troponin I concentrations between patients with high or low SDI. Adequate solute and fluid removal is the cornerstone of dialysis therapy and both are important targets of dialysis adequacy. Fluid overload is often seen in PD patients, and may contribute to high cardiac mortality [22, 23]. However, it is difficult to determine the volume status in PD patients using routine clinical methods [24]. NT-proBNP is synthesized in the LV in response to greater ventricular work, and is a marker of myocardial damage and fluid overload [6]. As shown in Table 6, log NT-proBNP was the most important predictor of cardiac dyssynchrony during the stress test, even after adjusting for other traditional parameters. Log NT-proBNP was also independently associated with PD adequacy, as shown in Tables 4 and 5. Therefore, elevated NT-proBNP levels may reflect fluid overload in CAPD patients, and is easy to measure in clinical settings. As indicated in Table 2, CAPD subset with a greater improvement in Kt/V change at 2 years showed less systolic LV wall stress as compared with patients with poorer improvements in Kt/V. Altered myocardial stress can result in the production of cytokines and reactive oxygen species, which can stimulate myocyte apoptosis [25] and extracellular matrix disruption [26], important triggers for destructive LV dilatation and remodeling [27]. Progressive LV dilatation and changes in chamber shape (i.e., increasing sphericity) can further stretch myocytes and upregulate the expression of stretch response proteins, which can induce pathologic cardiomyocyte hypertrophy [28]. In the current study, we found that patients with improvements in Kt/V had favorable echocardiographic parameters, including a lower LVMI, a smaller LV chamber, and a thinner LV wall, as compared with patients with a worsening in Kt/V. Taken together, our results suggest that higher dynamic LV dyssynchrony could predict lower Kt/V and unfavorable echocardiographic outcomes 2 years later.

We found that female CAPD patients had more pronounced dynamic LV dyssynchrony than males. This finding is consistent with the findings reported by Kuznetsova et al [29],. who reported that, in a study population with LV diastolic dysfunction, females had greater dyssynchrony compared with males. The differences in susceptibility between sexes could be related to sex hormones, such as estrogen [30].

Some limitations should be discussed. For example, the study sample size was relatively small and we only examined systolic dyssynchrony; regression analysis cannot address causality, only associations between two factors; and other unrecorded/untested parameters may influence the results.

Conclusions

Dynamic systolic dyssynchrony was strongly associated with future dialysis adequacy in CAPD patients. Log NT-proBNP was the important predictor of dynamic dyssynchrony. Our study confirmed the concept that cardiac dysfunction has an impact on dialysis adequacy. Future studies should evaluate stress-related diastolic dyssynchrony, and the associations in different study populations, such as patients with stage III–V CKD.

References

  1. Krediet RT, Lindholm B, Rippe B: Pathophysiology of peritoneal membrane failure. Perit Dial Int. 2000, 20: 22-42.

    Google Scholar 

  2. Rosengren BI, Rippe B: Blood flow limitation in vivo of small solute transfer during peritoneal dialysis in rats. J Am Soc Nephrol. 2003, 14: 1599-604. 10.1097/01.ASN.0000065551.75164.06.

    Article  PubMed  Google Scholar 

  3. Sawada T, Ishii Y, Tojimbara T, Nakajima I, Fuchinoue S, Teraoka S: The ACE inhibitor, quinapril, ameliorates peritoneal fibrosis in an encapsulating peritoneal sclerosis model in mice. Pharmacol Res. 2002, 46: 505-510. 10.1016/S1043661802002281.

    Article  CAS  PubMed  Google Scholar 

  4. Gayat E, Mor-Avi V, Weinert L, Shah SJ, Yodwut C, Lang RM: Noninvasive Estimation of Left Ventricular Compliance Using Three-Dimensional Echocardiography. J Am Soc Echocardiogr. 2012, 25: 661-666. 10.1016/j.echo.2012.03.004.

    Article  PubMed  Google Scholar 

  5. Unzek S, Popovic ZB, Marwick TH: Effect of recommendations on interobserver consistency of diastolic function evaluation. JACC Cardiovasc Imaging. 2011, 4: 460-467. 10.1016/j.jcmg.2011.01.016.

    Article  PubMed  Google Scholar 

  6. Paniagua R, Ventura MD, Avila-Díaz M, Hinojosa-Heredia H, Méndez-Durán A, Cueto-Manzano A, Cisneros A, Ramos A, Madonia-Juseino C, Belio-Caro F, García-Contreras F, Trinidad-Ramos P, Vázquez R, Ilabaca B, Alcántara G, Amato D: NT-proBNP, fluid volume overload and dialysis modality is independent predictors of mortality in ESRD patients. Nephrol Dial Transplant. 2010, 25: 551-557. 10.1093/ndt/gfp395.

    Article  CAS  PubMed  Google Scholar 

  7. Krittayaphong R, Boonyasirinant T, Saiviroonporn P, Thanapiboonpol P, Nakyen S, Udompunturak S: Correlation between NT-pro BNP levels and left ventricular wall stress, SIand extent of myocardial damage: a magnetic resonance imaging study. J Card Fail. 2008, 14: 687-694. 10.1016/j.cardfail.2008.05.002.

    Article  CAS  PubMed  Google Scholar 

  8. Gangji AS, Helal BA, Churchill DN, Brimble KS, Margetts PJ: Association between N-terminal propeptide B-type natriuretic peptide and markers of hypervolemia. Perit Dial Int. 2008, 28: 308-311.

    PubMed  Google Scholar 

  9. Badano LP, Boccalini F, Muraru D, Bianco LD, Peluso D, Bellu R, Zoppellaro G, Iliceto S: Current clinical applications of transthoracic three-dimensional echocardiography. J Cardiovasc Ultrasound. 2012, 20: 1-22. 10.4250/jcu.2012.20.1.1.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Kapetanakis S, Kearney MT, Siva A, Gall N, Cooklin M, Monaghan MJ: Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation. 2005, 112: 992-1000. 10.1161/CIRCULATIONAHA.104.474445.

    Article  CAS  PubMed  Google Scholar 

  11. Messika-Zeitoun D, Bellamy M, Avierinos JF, Breen J, Eusemann C, Rossi A, Behrenbeck T, Scott C, Tajik JA, Enriquez-Sarano M: Left atrial remodeling in mitral regurgitation–methodologic approach, physiological determinants, and outcome implications: a prospective quantitative Doppler-echocardiographic and electron beam-computed tomographic study. Eur Heart J. 2007, 28: 1773-1781. 10.1093/eurheartj/ehm199.

    Article  PubMed  Google Scholar 

  12. Lentine KL, Hurst FP, Jindal RM, Villines TC, Kunz JS, Yuan CM, Hauptman PJ, Abbott KC: Cardiovascular Risk Assessment Among Potential Kidney Transplant Candidates: Approaches and Controversies. Am J Kidney Dis. 2010, 5: 152-167.

    Article  Google Scholar 

  13. Lancellotti P, Moonen M: Left ventricular dyssynchrony: a dynamic condition. Heart Fail Rev. 2012, 17: 747-753. 10.1007/s10741-011-9275-x.

    Article  PubMed  Google Scholar 

  14. Matsumura Y, Hozumi T, Arai K, Sugioka K, Ujino K, Takemoto Y, Yamagishi H, Yoshiyama M, Yoshikawa J: Non-invasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods. Eur Heart J. 2005, 26: 1625-1632. 10.1093/eurheartj/ehi194.

    Article  PubMed  Google Scholar 

  15. London GM, Guerin AP, Pannier B, Marchais SJ, Safar ME: Large artery structure and function in hypertension and end-stage renal disease. J Hypertens. 1998, 16: 1931-1938. 10.1097/00004872-199816121-00012.

    Article  CAS  PubMed  Google Scholar 

  16. Wieskotten S, Heinke S, Wabel P, Moissl U, Becker J, Pirlich M, Keymling M, Isermann R: Bioimpedance-based identification of malnutrition using fuzzy logic. Physiol Meas. 2008, 29: 639-654. 10.1088/0967-3334/29/5/009.

    Article  CAS  PubMed  Google Scholar 

  17. Kobayashi D, Patel SR, Mattoo TK, Valentini RP, Aggarwal S: The impact of change in volume and left-ventricular hypertrophy on left-ventricular mechanical dyssynchrony in children with end-stage renal disease. Pediatr Cardiol. 2012, 33: 1124-1130. 10.1007/s00246-012-0266-z.

    Article  PubMed  Google Scholar 

  18. Hayashi SY, Seeberger A, Lind B, Nowak J, Do Nascimento MM, Lindholm B, Brodin LA: A single session of haemodialysis improves left ventricular synchronicity in patients with end-stage renal disease: a pilot tissue synchronization imaging study. Nephrol Dial Transplant. 2008, 23: 3622-3628. 10.1093/ndt/gfn311.

    Article  PubMed  Google Scholar 

  19. Aljaroudi W, Aggarwal H, Venkataraman R, Heo J, Iskandrian AE, Hage FG: Impact of left ventricular dyssynchrony by phase analysis on cardiovascular outcomes in patients with end-stage renal disease. J Nucl Cardiol. 2010, 17: 1058-1064. 10.1007/s12350-010-9271-x.

    Article  PubMed  Google Scholar 

  20. Bakkaloğlu SA, Ekim M, Koçak G, Atalay S, Tümer N: Impact of dialysis adequacy on cardiac function in pediatric CAPD patients. Perit Dial Int. 2001, 21: 395-400.

    PubMed  Google Scholar 

  21. Wang J, Kurrelmeyer KM, Torre-Amione G, Nagueh SF: Systolic and diastolic dyssynchrony in patients with diastolic heart failure and the effect of medical therapy. J Am Coll Cardiol. 2007, 49: 88-96. 10.1016/j.jacc.2006.10.023.

    Article  PubMed  Google Scholar 

  22. Ateş K, Nergizoğlu G, Keven K, Sen A, Kutlay S, Ertürk S, Duman N, Karatan O, Ertuğ AE: Effect of fluid and sodium removal on mortality in peri¬toneal dialysis patients. Kidney Int. 2001, 60: 767-776. 10.1046/j.1523-1755.2001.060002767.x.

    Article  PubMed  Google Scholar 

  23. Chen W, Guo LJ, Wang T: Extracellular water/intracellular water is a strong predictor of patient survival in incident peritoneal dialysis patients. Blood Purif. 2007, 25: 260-266. 10.1159/000101699.

    Article  PubMed  Google Scholar 

  24. Van Biesen W, Williams JD, Covic AC, Fan S, Claes K, Lichodziejewska-Niemierko M, Verger C, Steiger J, Schoder V, Wabel P, Gauly A, Himmele R, EuroBCM Study Group: Fluid status in peritoneal dialysis patients: the European Body Composition Monitoring (EuroBCM) study cohort. PLoS One. 2011, 6: e17148-10.1371/journal.pone.0017148.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  25. Kang PM, Izumo S: Apoptosis and heart failure: A critical review of the literature. Circ Res. 2000, 86: 1107-1113. 10.1161/01.RES.86.11.1107.

    Article  CAS  PubMed  Google Scholar 

  26. Wilson EM, Moainie SL, Baskin JM, Lowry AS, Deschamps AM, Mukherjee R, Guy TS, St John-Sutton MG, Gorman JH, Edmunds LH, Gorman RC, Spinale FG: Region- and type-specific induction of matrix metalloproteinases in post-myocardial infarction remodeling. Circulation. 2003, 107: 285-2863. 10.1161/01.CIR.0000044941.13346.74.

    Article  Google Scholar 

  27. Ratcliffe MB: Non-ischemic infarct extension: A new type of infarct enlargement and a potential therapeutic target. J Am Coll Cardiol. 2002, 40: 1168-1171. 10.1016/S0735-1097(02)02113-7.

    Article  Google Scholar 

  28. Sadoshima J, Jahn L, Takahashi T, Kulik TJ, Izumo S: Molecular characterization of the stretch-induced adaptation of cultured cardiac-cells -an in vitro model of load-induced cardiac-hypertrophy. J Biol Chem. 1992, 267: 10551-10560.

    CAS  PubMed  Google Scholar 

  29. Kuznetsova T, Bogaert P, Kloch-Badelek M, Thijs D, Thijs L, Staessen JA: Association of left ventricular diastolic function with systolic dyssynchrony: a population study. Eur Heart J Cardiovasc Imaging. 2012, Sep 21. [Epub ahead of print]

    Google Scholar 

  30. Cavasin MA, Sankey SS, Yu AL, Menon S, Yang XP: Estrogen and testosterone have opposing effects on chronic cardiac remodeling and function in mice with myocardial infarction. AJP-Heart Circ Physiol. 2003, 284: 1560-1569.

    Article  Google Scholar 

Pre-publication history

Download references

Acknowledgments

The authors wish to thank the certified nurse specialist, Ms Tsai-Hung Chang, and our CAPD staffs for their kind help with data collection. We also wish to thank Prof. CH Chang for revising the manuscript and thank Dr. Nicholas D. Smith for English editing. The study was supported by a research grant (97CCHIRP-31) from Changhua Christian Hospital.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chia-Chu Chang.

Additional information

Competing interests

All authors declared that they have no competing interest.

Authors’ contributions

HCH & CCC contributed in study design and data collection and all authors contributed in editing and drafting the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Huang, CH., Chang, CC., Chang, TL. et al. Dynamic cardiac dyssynchrony is strongly associated with 2-year dialysis adequacy in continuous ambulatory peritoneal dialysis patients. BMC Nephrol 14, 68 (2013). https://doi.org/10.1186/1471-2369-14-68

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2369-14-68

Keywords