Percutaneous closure of large VSD using a home-made fenestrated atrial septal occluder in 18-year-old with pulmonary hypertension

Abstract

Background

Hemodynamically significant muscular ventricular septal defects in children after the infantile period are a rare occurrence and ideal for transcatheter closure. In cases of severe concomitant pulmonary hypertension, it may be necessary to fenestrate the device. In this report, we present an 18-year old patient with a large mid-trabecular ventricular septal defect and severe pulmonary hypertension that underwent percutaneous closure of the defect with a home-made fenestrated atrial septal occluder.

Case presentation

An 18-year-old female patient referred to us with complaints of dyspnea (NYHA score of 2–3). Physical examination revealed an apical rumble and a harsh second heart sound. Echocardiographic examination revealed a large mid-trabecular ventricular septal defect with bidirectional shunt and the widest diameter measuring 22 mm on 2D echocardiography. Left and right heart cavities were enlarged. Before and after the vasoreactivity test performed during cardiac catheterization, average aortic pressure was 65 → 86 mmHg, average pulmonary artery pressure: 58 → 73 mmHg, Qp/Qs: 1.6 → 3.2, PVR: 4.6 → 4.3 Wood/U/m2 and PVR/SVR: 0.5 → 0.2. On left-ventricular angiocardiogram, the largest end-diastolic defect diameter was 21 mm. The closure procedure was performed with transthoracic echocardiographic guidance, using a 24 mm Cera septal occluder and a 14 F sheath dilator to make a 4.5-5 mm opening. Measured immediately after the procedure and during cardiac catheterization one month later, average aortic pressure was 75 → 75 mmHg, average pulmonary artery pressure: 66 → 30 mmHg, Qp/Qs 1.5 → 1.4, PVR: 4.4 → 2.9 Wood/U/m2 and PVR/SVR: 0.4 → 0.2. Transthoracic echocardiographic examination performed 24 hours after the procedure showed a max 35–40 mmHg gradient between the left and right ventricles through the fenestration. After the procedure, we observed sporadic early ventricular systoles and a nodal rhythm disorder that started after approximately 12 hours and spontaneously reverted to normal 9 days later.

Conclusion

In patients with large ventricular septal defects, large atrial septal occluders may be used. In cases with risk of pulmonary vascular disease, a safer option would be to close the defect using a manually fenestrated device.

Peer Review reports

Background

Hemodynamically significant muscular ventricular septal defects (VSD) in children after the infantile period are a rare occurrence and ideal for transcatheter closure [1]. Depending on the type, size, location and number of defects, it may be necessary to use an off-label device or multiple devices [24]. Additionally, in cases of severe concomitant pulmonary hypertension (PHT), it may be necessary to fenestrate the device [5]. In this report, we present an 18-year old patient with a large mid-trabecular VSD and severe PHT that underwent percutaneous closure of the defect with a home-made fenestrated atrial septal occluder (ASO).

Case presentation

An 18-year-old female patient referred to us with complaints of dyspnea (NYHA score of 2–3). An apical rumble and a harsh second heart sound were heard in physical examination. Echocardiographic examination revealed a large mid-trabecular VSD with bidirectional shunt and the widest diameter measuring 22 mm on 2D echocardiography (ECHO) (Figure 1; Additional file 1). The defect was located 9 mm proximal to the moderator band. Left and right heart cavities were enlarged; left ventricle, left atrium and right ventricle end-diastolic diameters were respectively 68 mm (Z score: +8.23), 44 mm (Z score: +6.22) and 41 mm (Z score: +10.3). Pulmonary artery diastolic pressure, which we were able to measure due to pulmonary insufficiency, was 58 mmHg. Before and after the vasoreactivity test with inhaled iloprost performed during cardiac catheterization, average aortic pressure was 65 → 86 mmHg, average pulmonary artery pressure: 58 → 73 mmHg, Qp/Qs: 1.6 → 3.2, PVR: 4.6 → 4.3 Wood/U/m2 and PVR/SVR: 0.5 → 0.2 (Table 1).

Figure 1
figure 1

Diameters of VSD on transthoracic echocardiogram.

Additional file 1: 2D and color flow echocardiographic imaging of VSD.(MP4 7 MB)

Table 1 Hemodynamic parameters during the vasoreactivity test, immediately after the procedure and one month later

On left-ventricular angiocardiogram, the largest end-diastolic defect diameter was 21 mm. The closure procedure was performed with transthoracic echocardiographic guidance, using a 24 mm Cera septal occluder (CSO, Lifetech Scientific Co., ltd, Shenzhen, China) and a 14 F sheath dilator to make a 4.5-5 mm opening (Figures 2 and 3). Measured immediately after the procedure and during cardiac catheterization one month later, average aortic pressure was 75 → 75 mmHg, average pulmonary artery pressure: 66 → 30 mmHg, Qp/Qs 1.5 → 1.4, PVR: 4.4 → 2.9 Wood/U/m2 and PVR/SVR: 0.4 → 0.2 (Table 1).

Figure 2
figure 2

Fenestration procedure and the fenestrated ASD device.

Figure 3
figure 3

2D imaging of device after the procedure.

Transthoracic echocardiographic examination performed 24 hours after the procedure showed a max 35–40 mmHg gradient between the left and right ventricles through the fenestration. At the follow-up examination one month later, the gradient level was the same and there was a 50 drop in pulmonary artery diastolic pressure compared to the pre-procedure value.The patient had a normal sinus rhythm prior to the procedure. After the procedure, we observed sporadic early ventricular systoles and a nodal rhythm disorder that started after approximately 12 hours and spontaneously reverted to normal 9 days later. The patient was put on dexamethasone for the nodal rhythm. Propranolol was started after Holter ECG showed intermittent non-sustained ventricular tachycardia (VT) attacks. When the initially intermittent nodal rhythm became permanent, the patient was switched to sotalol. The last ECG and Holter ECG showed a normal sinus rhythm with sporadic early ventricular systoles and no VT attacks (Figures 4 and 5). Holter ECG performed 1 month later showed no early ventricular systoles.

Figure 4
figure 4

Nodal rhythm (top strip) on ECG and non-sustained VT attack (bottom strip) on 24-hour Holter ECG.

Figure 5
figure 5

Patient ECG on day 9.

The patient was closely monitored for hemolysis due to the fenestration of the device, but none was observed.

The patient’s dyspnea (NYHA score 2–3 upon admission) started to recede on the 4-5th day after the procedure and was graded as 1–2 in the follow-up examination 1 month later.

Discussion

Transcatheter closure of congenital and acquired VSDs is a procedure that has gained widespread use in the recent years. Initially, VSD closure was performed using devices designed for atrial septal defects (ASD), but eventually special devices intended for closure of muscular and perimembranous defects were developed [6, 7]. Although there has been remarkable progress in production of specifically designed occlusion devices, demand for off-label or custom-made devices suitable for various types of defects remains high [2, 3, 8].

Transcatheter closure of postinfarction, traumatic or residual postoperative VSDs is mainly performed using ASOs [3, 9]. As ECHO and angiocardiographic measurements showed a large defect size in our patient, we elected to use a 24 mm ASO, a device 2–3 mm larger than the defect. The defect could have been closed using a 24 mm muscular VSD occluder or a post-myocardial infarction muscular VSD occluder as well; however, we preferred the ASO as it would allow for more convenient manual fenestration.

Long-term pulmonary hypertension may lead to a fixed increase in pulmonary vascular resistance. In some patients that have undergone VSD closure, pulmonary hypertension may persist or regress very slowly, in which case there may be hypertensive crisis-like exacerbations requiring long-term ventilation and specific treatment. In VSD cases with high pulmonary resistance, post-operative pulmonary hypertensive crises as well as acute congestive heart failure and respiratory failure may prove fatal. For these reasons, surgeons nowadays are instructed to leave an opening in the VSD patch or to use a flap patch that allows for left-to-right shunt [10]. For the same reasons, fenestration is now performed on transcatheter occluder devices. Home-made fenestrated devices have been safely used in cases of ASD with severe PHT under the assumption that fenestrated occluders reduce left-to-right shunt and in the long run, lower pulmonary arterial pressure [5]. Bruch et al. reported using a home-made fenestrated ASO that allowed for a minor to moderate bidirectional shunt in elderly patients with PHT and/or right heart failure. While the authors did not see any deterioration of right or left heart failure in their patient group, they observed an impressive symptomatic benefit [11].

As our patient was an 18-year-old with a large VSD and severe PHT, we performed a vasoreactivity test in order to assess whether the defect could be closed. The patient’s left heart cavities were found to be enlarged, the pulmonary artery flow velocity was high and the response to the vasoreactivity test was positive, so the patient was deemed a suitable candidate for transcatheter closure. However, as the patient was a young adult with bidirectional shunt and an enlarged right ventricle and pulmonary artery, we debated whether or not to fenestrate the device.

A review of literature did not reveal any cases with manually fenestrated devices used for closure of VSDs in patients with severe PHT. However, based on the Bruch study mentioned above and others that used fenestrated ASOs, we assumed that such a device in our case would allow for bidirectional shunt and could possibly reduce PHT in the long run. While no satisfactory reduction in pulmonary artery pressure was seen immediately after the procedure, transthoracic ECHO performed 24 hours later showed left-to-right gradient of 35–40 mmHg through the fenestration.

In the follow-up examination 1 month later, the gradient value was the same, average aortic pressure was 75 mmHg, average pulmonary artery pressure was 30 mmHg and PVR/SVR was 0.2.

Both minor and major complications such as hemolysis, cardiac perforation, device malposition, thromboembolism, temporary or permanent rhythm disorders, endocarditis and death may occur during, immediately after or in the follow-up of transcatheter defect closure [4, 12]. In our case, a nodal rhythm started 12 hours after the procedure and spontaneously reverted to normal 9 days later. Temporary junctional rhythms following closure of muscular VSDs have also been reported in the literature [12, 13].

Heart block occurring after placement of an oversized device can be attributed to the expansion of the device against the conducting tissue. Even if the device is not oversized, it may cause an inflammatory reaction or formation of scarring in the conduction tissue, in which case steroid therapy may be useful [14]. The nodal rhythm in our patient can be attributed to the fact that an ASO has a larger left disc and a narrower gap between the discs than a VSD device, which may have put pressure on the conduction system or the neighboring tissues.

Conclusion

In patients with large VSDs, large ASDs may be used as well as large muscular VSD occluders or post-myocardial infarction muscular VSD occluders. In cases with risk of pulmonary vascular disease, a safer option would be to close the defect using a manually fenestrated device.

Consent

Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor of this journal.

Abbreviations

VSD:

Ventricular septal defects

PHT:

Pulmonary hypertension

ASO:

Atrial septal occluder

ECHO:

Echocardiography

VT:

Ventricular tachycardia

ASD:

Atrial septal defects.

References

  1. Arora R, Trehan V, Thakur AK, Mehta V, Sengupta PP, Nigam M: Transcatheter closure of congenital muscular ventricular septal defect. J Interv Cardiol. 2004, 17: 109-115. 10.1111/j.1540-8183.2004.09872.x.

    Article  PubMed  Google Scholar 

  2. Baspinar O, Irdem A, Kilinc M: Off-label use of Amplatzer devices in congenital heart disorders during childhood. Acta Cardiol. 2013, 68: 31-35.

    PubMed  Google Scholar 

  3. Marinakis A, Vydt T, Dens J, Gewillig M, Van Deyk K, Budts W: Percutaneous transcatheter ventricular septal defect closure in adults with Amplatzer septal occluders. Acta Cardiol. 2007, 62: 391-395. 10.2143/AC.62.4.2022283.

    Article  PubMed  Google Scholar 

  4. Holzer R, Balzer D, Cao QL, Lock K, Hijazi ZM: Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry. J Am Coll Cardiol. 2004, 43: 1257-1263. 10.1016/j.jacc.2003.10.047.

    Article  PubMed  Google Scholar 

  5. Dell’avvocata F, Rigatelli G, Cardaioli P, Giordan M: Home-made fenestrated amplatzer occluder for atrial septal defect and pulmonary arterial hypertension. J Geriatr Cardiol. 2011, 8: 127-129. 10.3724/SP.J.1263.2011.00127.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Michel-Behnke I, Le TP, Waldecker B, Akintuerk H, Valeske K, Schranz D: Percutaneous closure of congenital and acquired ventricular septal defects–considerations on selection of the occlusion device. J Interv Cardiol. 2005, 18: 89-99. 10.1111/j.1540-8183.2005.04051.x.

    Article  PubMed  Google Scholar 

  7. Fu YC: Transcatheter device closure of muscular ventricular septal defect. Pediatr Neonatol. 2011, 52: 3-4. 10.1016/j.pedneo.2010.12.012.

    Article  PubMed  Google Scholar 

  8. Rohit MK, Gupta A: Transcatheter closure of large patent ductus arteriosus using custom made devices. Catheter Cardiovasc Interv. 2014, 00: 00-00.

    Google Scholar 

  9. Suh WM, Kern MJ: Transcatheter closure of a traumatic VSD in an adult requiring an ASD occluder device. Catheter Cardiovasc Interv. 2009, 74: 1120-1125. 10.1002/ccd.22141.

    Article  PubMed  Google Scholar 

  10. Rao PS, Raju V, Narayana M: Flap valved closure of ventricular septal defects with increased pulmonary vascular resistance. Interact Cardiovasc Thorac Surg. 2010, 11: 577-580. 10.1510/icvts.2010.243865.

    Article  PubMed  Google Scholar 

  11. Bruch L, Winkelmann A, Sonntag S, Scherf F, Rux S, Grad MO, Kleber FX: Fenestrated occluders for treatment of ASD in elderly patients with pulmonary hypertension and/or right heart failure. J Interv Cardiol. 2008, 21: 44-49. 10.1111/j.1540-8183.2007.00324.x.

    Article  PubMed  Google Scholar 

  12. Chessa M, Carminati M, Cao QL, Butera G, Giusti S, Bini RM, Hijazi ZM: Transcatheter closure of congenital and acquired muscular ventricular septal defects using the Amplatzer device. J Invasive Cardiol. 2002, 14: 322-327.

    PubMed  Google Scholar 

  13. Hijazi ZM, Hakim F, Al-Fadley F, Abdelhamid J, Cao QL: Transcatheter closure of single muscular ventricular septal defects using the amplatzer muscular VSD occluder: initial results and technical considerations. Catheter Cardiovasc Interv. 2000, 49: 167-172. 10.1002/(SICI)1522-726X(200002)49:2<167::AID-CCD11>3.0.CO;2-S.

    Article  CAS  PubMed  Google Scholar 

  14. Butera G, Chessa M, Carminati M: Percutaneous closure of ventricular septal defects. Cardiol Young. 2007, 17: 243-253.

    Article  PubMed  Google Scholar 

Pre-publication history

Download references

Acknowledgements

We thank Layla Rahimov who provided medical writing of this report in English.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Turkay Saritas.

Additional information

Competing interests

The authors declare that they have no financial and/or non-financial competing interests.

Authors’ contributions

AE and TS performed the transcatheter intervention. HK gathered patient data. CA and VT treated the patient’s arrhythmia, and contributed to the conception of the report. TS wrote the report. AE checked the report in terms of English grammar. All authors gave their final acceptance to the submission of this report. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kamali, H., Saritas, T., Erdem, A. et al. Percutaneous closure of large VSD using a home-made fenestrated atrial septal occluder in 18-year-old with pulmonary hypertension. BMC Cardiovasc Disord 14, 74 (2014). https://doi.org/10.1186/1471-2261-14-74

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2261-14-74

Keywords