Table 1

Electrophysiological parameters measured from control groups at 25°C and 30°C
yw Elav-Gal4 Gal80ts
25° 30° 25° 30° 25° 30°
n=14 n=11 n=17 n=17 n=30 n=26
Vm (mV) -66.3 ± 1.5 -69.7 ± 2.0 -63.8 ± 0.7 -65.6 ± 1.1 -68.3 ± 0.9 -66.1 ± 0.8
Rm (MΩ) 7.6 ± 0.4 11.6 ± 1.4 10.5 ± 0.8 9.6 ± 0.6 8.1 ± 0.7 9.7 ± 0.6
mEJP (mV) 0.8 ± 0.02 1.0 ± 0.08 1.0 ± 0.04 0.8 ± 0.05 1.0 ± 0.07 0.8 ± 0.05
mEJP (Hz) 2.4 ± 0.2 0.6 ± 0.1 3.1 ± 0.3 0.4 ± 0.06 1.1 ± 0.06 1.3 ± 0.3
UAS-dNSF2E/Q Gal80ts;UAS-dNSF2E/Q Elav-Gal4;Gal80ts; UAS-dNSF2E/Q
25° 30° 25° 30° 25° 30°
n=16 n=15 n=17 n=25 n=13 n=18
Vm (mV) -67.44 ± 1.1 -68.9 ± 1.2 -69.9 ± 1.4 -63.8 ± 0.6 -65.1 ± 1.2 -67.4 ± 1.3
Rm (MΩ) 11.7 ± 0.8 11.2 ± 0.8 8.2 ± 0.8 12.9 ± 0.8 7.2 ± 0.8 7.7 ± 0.7
mEJP (mV) 1.2 ± 0.05 1.3 ± 0.08 1.2 ± 0.09 0.7 ± 0.04 0.7 ± 0.05 0.7 ± 0.04
mEJP (Hz) 2.0 ± 0.1 1.3 ± 0.2 2.0 ± 0.2 0.8 ± 0.1 1.1 ± 0.3 0.7 ± 0.1

Vm, resting membrane potential; Rm, muscle fiber membrane resistance; mEJP, miniature excitatory junction potential.

Laviolette and Stewart

Laviolette and Stewart BMC Neuroscience 2013 14:124   doi:10.1186/1471-2202-14-124

Open Data